Table 18. C1001F00 to C1645300 checkpoints (continued)
v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in
the Action column until the problem is solved. If an action solves the problem, you can stop performing the
remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
Progress code
C162E4xyy
C1645300

C2001000 to C20082FF Virtual service processor checkpoints

The C2xx progress codes indicate the progress of a partition IPL that is controlled by the virtual service
processor. The virtual service processor progress codes end after the environment setup completes and
the specific operating system code continues the IPL.
The virtual service processor can start a variety of operating systems. Some codes are specific to an
operating system and therefore, do not apply to all operating systems.
Table 19 lists the progress codes that might be displayed during the power-on self-test (POST), along with
suggested actions to take if the system hangs on the progress code. Only when you experience a hang
condition should you take any of the actions described for a progress code.
In the following progress codes, x can be any number or letter.
Table 19. C2001000 to C20082FF checkpoints
v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in
the Action column until the problem is solved. If an action solves the problem, you can stop performing the
remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
Progress code
C2001000
C2001010
Description
VPD is being collected; yy indicates the
type of device from which VPD is being
collected
Starting a data synchronization operation
between the primary service processor
and the secondary service processor.
Description
Partition auto-startup during a platform
startup
Startup source
Action
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
Action
1. Go to "Recovering the system firmware" on
page 220.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Recovering the system firmware" on
page 220.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
Chapter 2. Diagnostics
93