IBM power PS700 Problem Determination And Service Manual page 190

Hide thumbs Also See for power PS700:
Table of Contents

Advertisement

Table 28. ssss-102 through ssss-640 SRNs (continued)
SRN
FFC
ssss-108
ssss
ssss-110
ssss
ssss-112
ssss
ssss-114
ssss
ssss-116
ssss
ssss-117
ssss
ssss-118
ssss 252B
ssss-120
ssss
178
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description and action
The bus test failed.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
The media format is corrupted.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
The diagnostic test failed.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
An unrecoverable hardware error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
A protocol error.
1. Make sure that the device, adapter and diagnostic firmware, and the application
software levels are compatible.
2. If you do not find a problem, call your operating-system support person.
A write-protect error occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
A SCSD command time-out occurred.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
A SCSD busy or command error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents