Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
A1D-05x
A1D-06x
A1D-07x
A1D-08x
A1D-09x
A1D-12x
A1D-13x
A1D-18x
174
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description
A non-critical error has been detected, a
service processor error accessing special
registers.
A non-critical error has been detected, a
service processor reports unknown
communication error.
A non-critical error has been detected,:
Internal service processor firmware
error or incorrect version.
A non-critical error has been detected,
another internal service processor
hardware error.
A non-critical error has been detected, a
service processor error accessing vital
product data EEPROM.
A non-critical error has been detected, a
service processor error accessing fan
sensor.
A non-critical error has been detected, a
service processor error accessing a
thermal sensor.
A non-critical error has been detected, a
service processor detected NVRAM
error.
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.