Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
A12-07x
A12-08x
A12-09x
A12-10x
A12-11x
A12-12x
A12-13x
A12-15x
168
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description
A non-critical error has been detected, a
memory bus/switch internal error.
A non-critical error has been detected, a
memory time-out error.
A non-critical error has been detected, a
system bus parity error.
A non-critical error has been detected, a
system bus time-out error.
A non-critical error has been detected, a
system bus protocol/transfer error.
A non-critical error has been detected,
an I/O host bridge time-out error.
A non-critical error has been detected, a
I/O host bridge address/data parity
error.
A non-critical error has been detected, a
system support function error.
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents