IBM power PS700 Problem Determination And Service Manual page 151

Hide thumbs Also See for power PS700:
Table of Contents

Advertisement

Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
887-113
887
887-114
887
887-115
887
887-116
887
887-117
887
887-118
887
887-120
887
887-121
B08
887-122
B09
887-123
887
887-124
887
887-125
887
887-202
887
887-203
887
887-209
887
887-304
887
887-305
887
887-306
887
887-307
887
887-319
887
887-400
887
887-401
887
887-402
887
887-403
887
887-405
887
Description and Action
External loopback (twisted pair) parity test failed. Go to "Performing the checkout
procedure" on page 184.
Ethernet loopback (twisted pair) fairness test failed. Go to "Performing the checkout
procedure" on page 184.
External loopback (twisted pair) fairness and parity tests failed. Go to "Performing
the checkout procedure" on page 184.
Twisted pair wrap data failed. Go to "Performing the checkout procedure" on page
184.
Software device configuration fails. Go to "Performing the checkout procedure" on
page 184.
Device driver indicates a hardware problem. Go to "Performing the checkout
procedure" on page 184.
Device driver indicates a hardware problem. Go to "Performing the checkout
procedure" on page 184.
Ethernet transceiver test failed. Go to "Performing the checkout procedure" on page
184.
Ethernet 10 base-2 transceiver test failed. Go to "Performing the checkout procedure"
on page 184.
Internal loopback test failed. Go to "Performing the checkout procedure" on page
184.
Software error log indicates a hardware problem. Go to "Performing the checkout
procedure" on page 184.
Fuse test failed. Go to "Performing the checkout procedure" on page 184.
Vital Product Data test failed. Go to "Performing the checkout procedure" on page
184.
Vital Product Data test failed. Go to "Performing the checkout procedure" on page
184.
RJ-45 converter test failed. Go to "Performing the checkout procedure" on page 184.
Coprocessor internal test failed. Go to "Performing the checkout procedure" on page
184.
Internal loopback test failed. Go to "Performing the checkout procedure" on page
184.
Internal loopback test failed. Go to "Performing the checkout procedure" on page
184.
External loopback test failed. Go to "Performing the checkout procedure" on page
184.
Software device driver indicates a hardware failure. Go to "Performing the checkout
procedure" on page 184.
Fuse test failed. Go to "Performing the checkout procedure" on page 184.
Circuit breaker for Ethernet test failed. Go to "Performing the checkout procedure"
on page 184.
Ethernet 10 Base-2 transceiver test failed. Go to "Performing the checkout
procedure" on page 184.
Ethernet 10 Base-T transceiver test failed. Go to "Performing the checkout
procedure" on page 184.
Ethernet- network Rerun diagnostics in advanced mode for accurate problem
determination. Go to "Performing the checkout procedure" on page 184.
139
Chapter 2. Diagnostics

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents