Table 15. B700xxxx Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
0601
0602
0611
0621
0641
0650
0651
0803
0804
0A00
0A01
0A10
1150
1151
1152
1160
1161
1730
Description
Informational system log entry only.
System firmware detected an error
condition.
There is a problem with the system
hardware clock; the clock time is
invalid.
Informational system log entry only.
System firmware detected an error.
System firmware detected an error.
Resource management was unable to
allocate main storage. A platform dump
was initiated.
The system detected an error in the
system clock hardware
Informational system log entry only.
Informational system log entry only.
Informational system log entry only.
Informational system log entry only.
Informational system log entry only.
Informational system log entry only.
Informational system log entry only.
Informational system log entry only.
Service processor failure
Informational system log entry only.
The VPD for the system is not what was
expected at startup.
Action
No corrective action is required.
Note: This code and associated data can be
used to determine why the time of day for a
partition was lost.
1. Collect the event log information.
2. Go to "Isolating firmware problems" on
page 218.
Use the operating system to set the system
clock.
No corrective action is required.
1. Collect the platform dump information.
2. Go to "Isolating firmware problems" on
page 218.
1. Collect the event log.
2. Collect the platform dump data.
3. Collect the partition configuration
information.
4. Go to "Isolating firmware problems" on
page 218.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
260.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
No corrective action is required.
1. Go to "Isolating firmware problems" on
page 218.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
No corrective action is required.
Replace the management card, as described in
"Removing the tier 2 management card" on
page 255 and "Installing the tier 2 management
card" on page 256.
Chapter 2. Diagnostics
41