v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
6907
6908
6909
6911
6912
6944
6950
6951
6952
6953
6954
6955
6956
6965
6970
Description
System bus error
System bus error
System bus error
Platform LIC unable to find or retrieve
VPD LID file.
Platform LIC unable to find or retrieve
VPD LID file.
Informational system log entry only.
A platform dump has occurred.
An error occurred because a partition
needed more NVRAM than was
available.
Informational system log entry only.
PHYP NVRAM is unavailable after a
service processor reset and reload.
Informational system log entry only.
Informational system log entry only.
An NVRAM failure was detected.
Informational system log entry only.
PCI host bridge failure
Action
1. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
2. Go to "Isolating firmware problems" on
page 218.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
260.
1. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
2. Go to "Isolating firmware problems" on
page 218.
Check for server firmware updates; then,
install the updates if available.
Check for server firmware updates; then,
install the updates if available.
No corrective action is required.
1. Collect the platform dump information.
2. Go to "Isolating firmware problems" on
page 218.
Use the Integrated Virtualization Manager
(IVM) or management console to delete one or
more partitions.
No corrective action is required.
Go to "Isolating firmware problems" on page
218.
No corrective action is required.
No corrective action is required.
Go to "Isolating firmware problems" on page
218.
No corrective action is required.
1. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
2.
If the problem persists, use the "PCI
expansion card (PIOCARD) problem
isolation procedure" on page 194 to
determine the failing component.
Chapter 2. Diagnostics
45