IBM power PS700 Problem Determination And Service Manual page 63

Hide thumbs Also See for power PS700:
Table of Contents

Advertisement

Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
BA000091
BA00E820
BA00E830
BA00E840
BA00E843
BA00E850
BA00E860
BA010000
BA010001
Description
Unable to load a firmware code update
module
An lpevent communication failure
occurred
Failure when initializing ibm,event-scan
Failure when initializing PCI hot-plug
Failure when initializing the interface to
AIX or Linux
Failure when initializing dynamic
reconfiguration
Failure when initializing sensors
There is insufficient information to boot
the systems
The client IP address is already in use
by another network device
Action
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
Verify that all of the IP addresses on the
network are unique; then, retry the operation.
Chapter 2. Diagnostics
51

Hide quick links:

Advertisement

Table of Contents
loading