IBM power PS700 Problem Determination And Service Manual page 184

Hide thumbs Also See for power PS700:
Table of Contents

Advertisement

Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
A15-12x
A15-13x
A15-14x
A15-17x
A15-19x
A15-20x
A15-21x
172
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description
Sensor detected redundant power
supply failure.
Sensor detected a redundant FRU that
has failed.
Power fault due to unspecified cause.
Internal redundant power supply
failure.
Fan failure.
Non-critical cooling problem, loss of
redundant fan.
Over temperature condition.
FRU/action
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
2. If no entry is found, Replace the
system-board.
1. Make sure that:
a. The room ambient temperature is within
the system operating environment.
b. There is unrestricted air flow around the
system.
c. All system covers are closed.
d. There are no fan failures
2. Check the BladeCenter management-module
event log; if an error was recorded by the
system, see "POST progress codes
(checkpoints)" on page 84.
3. If no entry is found, Replace the
system-board.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents