Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
BA017020
BA017021
BA01B010
BA01B011
BA01B012
BA01B013
56
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description
Failed to open the TFTP package
Failed to load the TFTP file
Opening the BOOTP node failed.
BOOTP failed to read from the network
BOOTP failed to write to the network
The discover mode is invalid
Action
Verify that the Trivial File Transfer Protocol
(TFTP) parameters are correct.
Verify that the TFTP server and network
connections are correct.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
Perform the following actions that checkpoint
CA00E174 describes:
1. Verify that:
v The bootp server is correctly configured;
then, retry the operation.
v The network connections are correct;
then, retry the operation.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
Perform the following actions that checkpoint
CA00E174 describes:
1. Verify that:
v The bootp server is correctly configured;
then, retry the operation.
v The network connections are correct;
then, retry the operation.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
184.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 260.