Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 8406," on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
BA040060
BA050001
BA050004
BA05000A
BA060008
BA06000B
BA06000C
BA060020
BA060021
Description
Setting the firmware boot side for the
next boot failed.
Failed to reboot a partition in logical
partition mode
Failed to locate service processor device
tree node.
Failed to send boot failed message
No configurable adapters found by the
Remote IPL menu in the SMS utilities
The system was not able to find an
operating system on the devices in the
boot list.
A pointer to the operating system was
found in non-volatile storage.
The environment variable "boot-device"
exceeded the allowed character limit.
The environment variable "boot-device"
contained more than five entries.
Action
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
This error occurs when the firmware cannot
locate any LAN adapters that are supported by
the remote IPL function. Verify that the devices
in the remote IPL device list are correct using
the SMS menus.
Go to "Boot problem resolution" on page 190.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.
1. Go to "Checkout procedure" on page 184.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 260.