Table 28. ssss-102 through ssss-640 SRNs (continued)
SRN
FFC
ssss-134
252B
software
ssss-135
ssss 252B
software
ssss-136
ssss
ssss-137
ssss 252B
ssss-138
ssss
ssss-140
199 252B
ssss
ssss-640
ssss
180
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description and action
The adapter failed to configure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
The device failed to configure.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
The certify operation failed.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
Unit attention condition has occurred on the Send Diagnostic command.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
Error log analysis indicates that the disk drive is operating at a higher than
recommended temperature.
1. Make sure that:
v The ventilation holes in the blade server bezel are not blocked.
v The management-module event log is not reporting any system environmental
warnings.
2. If the problem remains, call IBM support.
Error log analysis indicates poor signal quality.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.
Error log analysis indicates a path error.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Replace the system board and chassis assembly, as described in "Replacing the
FRU system-board and chassis assembly" on page 260.