Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
950-2506
2506 221
2506-102E
722
2506-3002
722
2506-3010
722
2506-3020
-
2506-3100
-
2506-3109
-
2506-3110
-
2506-4010
-
2506-4020
-
2506-4030
-
2506-4040
-
2506-4041
-
2506-4050
-
2506-4060
-
2506-4100
-
2506-4101
-
2506-4110
-
2506-4150
2506
2506-4160
2506
2506-7001
722
140
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)
Description and Action
Missing options resolution for 3Gb SAS Adapter card.
Try each of the following steps. After reseating, removing, or replacing a part, retry
the operation.
1. Check the BladeCenter management-module event log. If an error was recorded
by the system, see "POST progress codes (checkpoints)" on page 84.
2. Replace any parts reported by the diagnostic program.
3. Reseat the 3Gb SAS Adapter card.
4. Replace the 3Gb SAS Adapter card.
5. Replace the system-board.
Out of alternate disk storage for storage. Go to "Performing the checkout procedure"
on page 184.
Addressed device failed to respond to selection. Go to "Performing the checkout
procedure" on page 184.
Disk returned wrong response to adapter. Go to "Performing the checkout
procedure" on page 184.
Storage subsystem configuration error. Go to "Performing the checkout procedure"
on page 184.
Controller detected device bus interface error. Go to "Performing the checkout
procedure" on page 184.
Controller timed out a device command. Go to "Performing the checkout procedure"
on page 184.
Device bus interface error. Go to "Performing the checkout procedure" on page 184.
Configuration error, incorrect connection between cascaded enclosures. Go to
"Performing the checkout procedure" on page 184.
Configuration error, connections exceed IOA design limits. Go to "Performing the
checkout procedure" on page 184.
Configuration error, incorrect multipath connection. Go to "Performing the checkout
procedure" on page 184.
Configuration error, incomplete multipath connection between controller and
enclosure detected. Go to "Performing the checkout procedure" on page 184.
Configuration error, incomplete multipath connection between enclosure and device
detected. Go to "Performing the checkout procedure" on page 184.
Attached enclosure does not support required multipath function. Go to "Performing
the checkout procedure" on page 184.
Multipath redundancy level got worse. Go to "Performing the checkout procedure"
on page 184.
Device bus fabric error. Go to "Performing the checkout procedure" on page 184.
Temporary device bus fabric error. Go to "Performing the checkout procedure" on
page 184.
Unsupported enclosure function detected. Go to "Performing the checkout
procedure" on page 184.
PCI bus error detected by controller. Go to "Performing the checkout procedure" on
page 184.
PCI bus error detected by controller. Go to "Performing the checkout procedure" on
page 184.
Temporary disk data error. Go to "Performing the checkout procedure" on page 184.