Section 3: Programming; User Programming - Honeywell MRP-2002 Instruction Manual

Agent release control system six-zone releasing fire control panel
Hide thumbs Also See for MRP-2002:
Table of Contents

Advertisement

NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION AND OTHER INVOLVED PARTIES
This product incorporates field-programmable software. In order for the product to comply with the requirements in the
Standard for Control Units and Accessories for Fire Alarm Systems, UL 864, certain programming features or options must be
Program feature or option
ANN-80 Lock Enable
Combo
Combo w/AutoResettable
Superv
NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION AND OTHER INVOLVED PARTIES
This product incorporates field-programmable software. In order for the product to comply with the requirements in
CAN/ULC-S527, Standard for Control Units for Fire Alarm Systems, certain programming features or options must be limited to
Program feature or
option
Release Circuit Short
Supervision
Canadian Option

3.1 User Programming

The FACP is completely field programmable using the panel keypad and requires no special soft-
ware skills. While programming the FACP, the fire protection capabilities of the control panel are
enabled. Programming Mode times-out after 10 minutes of inactivity.
Program Templates have been provided to allow the panel to be quickly programmed with typical
job-site configurations. Refer to "Circuit Mapping and Cross-Zoning" on page 95 for an
explanation of mapping and cross-zoning and "FACP Configuration Templates" on page 100 for a
detailed description of each template.
Site-specific programming may be accomplished:
• by Manual programming or editing, using the FACP keypad
The System All Normal screen will be displayed in a programmed system with no active alarms,
troubles or supervisories, as illustrated below:
50

Section 3: Programming

limited to specific values or not used at all as indicated below.
Permitted in UL 864? (Y/N)
Y
Y
Y
specific values or not used at all as indicated below.
Permitted in ULC-S527?
(Y/N)
Y
Y
Possible settings
Lock Enable Yes
Lock Enable No
Refer to Lock Enable in "ANN-
80 Options" on page 72.
Refer to Table 3.1 on page 55.
Refer to Table 3.1 on page 55.
Possible settings
UNSUPV Shorts
SUPV Shorts
Refer to "Release Circuit 1 or Release
Circuit 2" on page 59.
ON
OFF
Refer to "Canadian Option" on page 69.
SYSTEM ALL NORMAL
10:00A 092105
MRP-2002 Series Instruction Manual — P/N 53049:E5 7/28/2016
Settings permitted in UL
864
Lock Enable Yes
One Waterflow and one
Supervisory device
One Waterflow and one
Supervisory device
Settings permitted in
ULC-S527
SUPV Shorts
ON