Summary of Contents for Eaton Powerware Prestige Series 1500 VA
Page 1
® powerware Prestige Series 650 VA - 1500 VA Installation and Operator’s Manual for IBM Applications...
Page 2
Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonic standards and EU directives: Harmonic Standards: EN 50091-1-1 and EN 50091-2 EU Directives: 73/23/EEC, Council Directive on equipment designed for use within certain voltage limits 93/68/EEC, Amending Directive 73/23/EEC 89/336/EEC, Council Directive relating to electromagnetic compatibility 92/31/EEC, Amending Directive 89/336/EEC relating to EMC...
Page 3
Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Page 5
UICK NSTALL 120V Model Installation If you are connecting the UPS to an AS/400, the QUPSDLYTIM system value for the UPS Monitoring feature should be set. See “UPS Monitoring” on page 54 for instructions. For the AS/400 interface, plug the AS/400 communications cable into the serial port on the UPS rear panel.
Page 6
Quick Install 230V Model Installation NOTE For 208, 220, or 240V models, follow the instructions for changing the output voltage on page 39. If you are connecting the UPS to an AS/400, the QUPSDLYTIM system value for the UPS Monitoring feature should be set. See “UPS Monitoring” on page 54 for instructions. For the AS/400 interface, plug the AS/400 communications cable into the serial port on the UPS rear panel.
Page 7
Quick Install UPS with Optional 120V PPDM Installation If you are connecting the UPS to an AS/400, the QUPSDLYTIM system value for the UPS Monitoring feature should be set. See “UPS Monitoring” on page 54 for instructions. PowerPass Distribution Module (PPDM) Cabinet Battery...
Page 8
Quick Install For the AS/400 interface, plug the AS/400 communications cable into the serial port on the UPS rear panel. Plug the other end of the cable into the connector, located on the back of the system unit, labeled “UPS” (AS/400 Models 600 and S10).
Page 9
Quick Install UPS with Optional 230V PPDM Installation NOTE For 208, 220, or 240V models, follow the instructions for changing the output voltage on page 47. If you are connecting the UPS to an AS/400, the QUPSDLYTIM system value for the UPS Monitoring feature should be set.
Page 10
Quick Install Battery Breaker For the AS/400 interface, plug the AS/400 communications cable into the serial port on the UPS rear panel. Plug the other end of the cable into the connector, located on the back of the system unit, labeled “UPS” (AS/400 Models 600 and S10).
C H A P T E R 1 NTRODUCTION Congratulations on the purchase of your Powerware Prestige Series uninterruptible power system (UPS). The Prestige UPS meets the toughest measures of superior design and manufacturing, including ISO 9001. You now own the most reliable power protection available. The Prestige provides a steady, well-regulated power supply for your computing and communications equipment, while protecting it from the frequent irregularities that are inherent in commercially available power.
Introduction UPS Model and Battery Configurations This UPS is designed to work with single-phase, three-wire, AC power sources. There are two important considerations when selecting the UPS model and battery configuration to properly safeguard your equipment: Load requirements Battery times Load Requirements The load is the equipment to be protected by the UPS.
Introduction 3. Add all of the resultant VA ratings together to obtain the total load requirements of the equipment to be protected (see Figure 2). If the load consists of the power-factor corrected supplies, it is recommended to use total watts for the load requirements.
Page 16
Introduction To prepare for a power outage at your installation, ensure that you have sufficient battery time available. To do this, take a few minutes to determine your approximate battery time by completing the following steps: Battery Time Load Load Requirements UPS Model Battery Cabinets...
Introduction Special Symbols The following common symbols may be found on the UPS: LOAD ON - Press the button with this symbol to energize the output receptacles (Output On). - Press the button with this symbol to de-energize LOAD OFF the output receptacles (Output Off).
Page 20
Introduction This page intentionally left blank. Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
C H A P T E R 2 AFETY ARNINGS I M P O R T A N T S A F E T Y I N S T R U C T I O N S SAVE THESE INSTRUCTIONS. This manual contains important instructions that you should follow during installation of the UPS.
Page 22
Safety Warnings To comply with international standards and wiring regulations, the total equipment connected to the output of this UPS must not have an earth leakage current greater than 2.75 milliamperes. The wall outlet must be within 2 meters of the equipment and accessible to the operator.
Page 23
Safety Warnings Brug kun den netledning, som blev leveret med UPS’en. Denne netledning er tilsluttet ifølge specifikationerne for NEC (National Electrical Code). Sørg for, at stikket, som skal bruges til UPS’en, er tilsluttet ifølge de samme specifikationer for at undgå skade på dit udstyr. Sørg for, at der er overstrømsbeskyttelse på AC-stikket på...
Safety Warnings Belangrijke Veiligheidsinstructies BELANGRIJKE VEILIGHEIDSINSTRUCTIES BEWAAR DEZE INSTRUCTIES DEZE HANDLEIDING BEVAT BELANGRIJKE VEILIGHEIDSINSTRUCTIES G E V A A R Deze UPS bevat LEVENSGEVAARLIJKE ELEKTRISCHE SPANNING. Alle reparaties en onderhoud dienen UITSLUITEND DOOR ERKEND SERVICEPERSONEEL te worden uitgevoerd. Er bevinden zich GEEN ONDERDELEN in de UPS die DOOR DE GEBRUIKER kunnen worden GEREPAREERD.
Safety Warnings Verwijder de ingangsnoer niet of haal de stekker van de ingangsnoer er niet uit terwijl de UPS aan staat. Hierdoor zou de UPS en uw aangesloten apparatuur geen aardebeveiliging meer hebben. Om aan de internationale normen en bedradingsvoorschriften te voldoen mag de gehele apparatuur die op de uitgang van deze UPS is aangesloten, geen aardlekstroom van meer dan 2,75 milliampère hebben.
Page 26
Safety Warnings Käytä vain tämän UPS-laitteen mukana toimitettua virtakaapelia, joka on kytketty kansallisten määräysten mukaisesti. Varmista, että UPS-laitteen kanssa käytetty pistorasia on johdotettu näiden samojen määritysten mukaisesti, jotta laitteet eivät vahingoittuisi. Varmista myös, että asennuksen yhteydessä vaihtovirran pistorasia varustetaan ylivirtasuojauksella. Työnnä kosketin kokonaan pistorasiaan. Käytä...
Page 27
Safety Warnings Consignes de sécurité CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES INSTRUCTIONS CE MANUEL CONTIENT DES CONSIGNES DE SÉCURITÉ IMPORTANTES D A N G E R ! Cet onduleur contient des TENSIONS MORTELLES. Toute opération d’entretien et de réparation doit être EXCLUSIVEMENT CONFIÉE A UN PERSONNEL QUALIFIÉ AGRÉÉ. AUCUNE PIÈCE RÉPARABLE PAR L’UTILISATEUR ne se trouve dans l’onduleur.
Page 28
Safety Warnings Ne pas retirer le cordon d’alimentation lorsque l’onduleur est sous tension sous peine de supprimer la mise à la terre de l’onduleur et du matériel connecté. Afin d’être conforme aux normes et règlements internationaux de câblage, le courant de fuite à la terre de la totalité du matériel branché sur la sortie de l’onduleur ne doit pas dépasser 2,75 mA.
Page 29
Safety Warnings Nur das Netzkabel verwenden, das dieser USV beiliegt. Dieses Kabel ist gemäß den Spezifikationen des International Electrical Code (IEC) verdrahtet. Sicherstellen, daß die Wandsteckdose, die für die USV verwendet wird, gemäß den selben Spezifikationen verdrahtet ist, um eine eschädigung der Geräte zu vermeiden.
Page 30
Safety Warnings ÐñïåéäïðïéÞóåéò ÁóöÜëåéáò ÓÇÌÁÍÔÉÊÅÓ ÏÄÇÃÉÅÓ ÁÓÖÁËÅÉÁÓ ÖÕËÁÎÔÅ ÁÕÔÅÓ ÔÉÓ ÏÄÇÃÉÅÓ ÔÏ ÐÁÑÏÍ ÅÃ×ÅÉÑÉÄÉÏ ÐÅÑÉÅ×ÅÉ ÓÇÌÁÍÔÉÊÅÓ ÏÄÇÃÉÅÓ ÁÓÖÁËÅÉÁÓ Ê É Í Ä Õ Í Ï Ó Áõôü ôï UPS ðåñéÝ÷åé ÈÁÍÁÔÇÖÏÑÁ ÔÁÓÇ. ¼ëåò ïé åðéóêåõÝò êáé ïé óõíôçñÞóåéò ðñÝðåé íá ãßíïíôáé ÌÏÍÏ ÁÐÏ ÅÎÏÕÓÉÏÄÏÔÇÌÅÍÏ ÃÉÁ ÔÇ...
Safety Warnings Avvisi di sicurezza IMPORTANTI ISTRUZIONI DI SICUREZZA CONSERVARE QUESTE ISTRUZIONI QUESTO MANUALE CONTIENE IMPORTANTI ISTRUZIONI DI SICUREZZA P E R I C O L O la TENSIONE contenuta in questo gruppo statico di continuità è LETALE. Tutte le operazioni di riparazione e di manutenzione devono essere effettuate ESCLUSIVAMENTE DA PERSONALE TECNICO AUTORIZZATO.
Safety Warnings per ridurre il rischio di incendio o di scossa elettrica, installare il gruppo statico di continuità in un ambiente interno a temperatura ed umidità controllata, privo di agenti contaminanti conduttivi. La temperatura ambiente non deve superare i C. Non utilizzare l’unità in prossimità di acqua o in presenza di umidità eccessiva (95% max).
Page 34
Safety Warnings Batterier må aldri åpnes eller ødelegges. Frigjorte elektrolytter er skadelige for hud og øyne og kan være ekstremt giftige. Bruk kun den strømforsyningskabelen som følger med denne UPS’en. Strømkabelen er koblet i overensstemmelse med spesifikasjonene i IECs (International Electrical Code) bestemmelser.
Page 35
Safety Warnings Regulamentos de Segurança INSTRUÇÕES DE SEGURANÇA IMPORTANTES GUARDE ESTAS INSTRUÇÕES ESTE MANUAL CONTÉM INSTRUÇÕES DE SEGURANÇA IMPORTANTES C U I D A D O A UPS contém VOLTAGEM MORTAL. Todos os reparos e assistência técnica devem ser executados SOMENTE POR PESSOAL DA ASSISTÊNCIA TÉCNICA AUTORIZADO. Não há...
Page 36
Safety Warnings Para estar de acordo com os padrões internacionais e os regulamentos de fiação, o equipamento total conectado à saída desta UPS não deve ter uma corrente de fuga à terra maior que 2,75 miliampères. O soquete de alimentação principal deve estar no máximo dois metros do equipamento e acessível ao operador.
Page 37
Safety Warnings Никогда не открывайте и не деформируйте аккумуляторы. Вытекающий электролит опасен для кожи и глаз, и может быть крайне токсичным. Пользуйтесь только сетевым шнуром, поставляемым в комплекте с ИБП. Разводка сетевого шнура выполнена в соответствии с требованиями Международных электрических норм (IEC). Во избежание...
Safety Warnings Advertencias de Seguridad INSTRUCCIONES DE SEGURIDAD IMPORTANTES GUARDE ESTAS INSTRUCCIONES ESTE MANUAL CONTIENE INSTRUCCIONES DE SEGURIDAD IMPORTANTES P E L I G R O Este SIE contiene VOLTAJES MORTALES. Todas las reparaciones y el servicio técnico deben ser efectuados SOLAMENTE POR PERSONAL DE SERVICIO TÉCNICO AUTORIZADO.
Page 39
Safety Warnings No retire o desenchufe el cable de entrada mientras el SIE se encuentre encendido. Esto suprime la descarga a tierra de seguridad del SIE y de los equipos conectados al SIE. Para cumplir con los estándares internacionales y las normas de instalación, la totalidad de los equipos conectados a la salida de este SIE no debe tener una intensidad de pérdida a tierra superior a los 2,75 miliamperios.
Page 40
Safety Warnings Använd endast den nätsladd som medföljer denna UPS-enhet. Nätsladden är kompatibel med IEC-specifikationerna (International Electrical Code). Kontrollera att det vägguttag som ska användas med UPS-enheten är draget enligt samma specifikationer, så att skada på utrustningen undviks. Kontrollera att det finns överspänningsskydd för växelströmsuttaget vid installationstillfället.
Page 41
Safety Warnings Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
Page 42
Safety Warnings Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
Page 43
Safety Warnings Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
Page 44
Safety Warnings Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
Page 45
Safety Warnings Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
Page 46
Safety Warnings This page intentionally left blank. Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
C H A P T E R 3 NSTALLATION The following sections describe UPS storage requirements and the installation and startup of the UPS. Unpacking and Inspection Carefully unpack the UPS and optional battery cabinets, making sure to retain the packaging materials. Examine each unit carefully for any signs of damage and immediately notify your distributor if damage is present.
Installation Selecting an Installation Option In addition to the standard Prestige, the unit has two optional PowerPass Distribution Modules. Use the following flow chart to decide which installation option is right for you. See “UPS with Do you have an Optional PPDM optional PPDM? Installation”...
Page 49
Installation Cabinet Air Vents Battery Cabinet Battery Cabinet UPS Cabinet Stacked Cabinets Side-by-Side Cabinets Figure 4. Cabinet Setup 3. Verify the circuit breaker on all battery cabinets is in the OFF (O) position (see Figure 5). 4. Plug the battery output connector on the battery cable into the external battery connector on the UPS.
Installation 4. The equipment to be protected by the UPS should be powered off. Plug the equipment into the power output receptacles on the UPS rear panel. Do not protect laser printers with the UPS because of the exceptionally high cyclic power requirements of the heating elements.
Page 52
Installation 3. Plug the UPS power supply cord into the input connector on the UPS rear panel. 4. Press and hold the Output Off button while plugging the other end of the power supply cord into a grounded, three-wire, AC receptacle that has been wired in accordance with national wiring rules.
Installation 11. The equipment to be protected by the UPS should be powered off. Plug the equipment into the power output receptacles on the UPS rear panel. Do not protect laser printers with the UPS because of the exceptionally high cyclic power requirements of the heating elements.
Page 54
Installation Steps 3 through 7 are for battery installation. You can install additional battery cabinets while the UPS is operating, but confirm the UPS is not in Battery mode (see page 51). If you do not have optional battery cabinets, skip to Step 8 on page 44.
Page 55
Installation 7. Switch the circuit breaker on all battery cabinets to the ON ( position. PPDM Bypass Switch Power Output Output Receptacles Breakers (5-15R) Power Output Utility Input Receptacle Connector (IEC 320-C19) (IEC 320-C20) Serial Port Y-Cord Power Output UPS Cabinet Receptacles (see note) Breaker External Battery...
Page 56
Installation 8. Verify the Bypass switch on the PPDM rear panel is in the NORMAL position. 9. Plug the Y-cord into the power connectors on the UPS as shown in Figure 8 and Figure 9. 10. The equipment to be protected by the UPS should be powered off.
Page 57
Installation PPDM Bypass Switch Utility Input Connector Power Output (IEC 320-C20) Receptacle (IEC 320-C19) Output Breakers Power Output Receptacles (IEC 320-C13) Serial Port Y-Cord Power Output UPS Cabinet Receptacles (see note) Breaker External Battery Connector Power Input Connector Battery Output Connector Battery Cable Battery Cabinet...
Installation UPS with PPDM Startup for 120V Models To start up the UPS for 120V models: 1. If you are connecting the UPS to an AS/400, the QUPSDLYTIM system value for the UPS Monitoring feature should be set. See “UPS Monitoring” on page 54 for instructions. 2.
Installation UPS with PPDM Startup for 208V-240V Models To start up the UPS for 208V-240V models: 1. If you are connecting the UPS to an AS/400, the QUPSDLYTIM system value for the UPS Monitoring feature should be set. See “UPS Monitoring” on page 54 for instructions. 2.
Installation 8. Press and hold the Output On button until the alarm beeps to select and save the output voltage. Failure to release the button immediately after the beep will cause the UPS to abort the setup. NOTE If you do not save a selection within two minutes, the setup automatically aborts and switches back to the original configuration.
C H A P T E R 4 UPS O PERATION This chapter covers the operation of the UPS including front panel functions, operating modes, using the Battery Start feature, shutting down the UPS, and using the PowerPass Distribution Module. UPS Front Panel The UPS front panel has three distinct functions: Displays the UPS operational mode (Normal, Bypass, or Battery).
UPS Operation Operating Modes After you install and apply power to the UPS, the UPS filters and regulates incoming AC power, eliminating noise and voltage spikes, and provides consistent power to your equipment (see Figure 12). While power is applied to the UPS, the maintenance-free battery is automatically kept in a fully-charged condition.
UPS Operation Bypass Mode indicator and the indicator illuminate simultaneously, indicating Bypass mode (see Figure 14). When the UPS is in Bypass mode, the load is powered by utility power. However, utility power continues to be passively filtered by the UPS. OVERLOAD SITE FAULT OVERTEMP...
UPS Operation When shutdown is imminent, the Self Test indicator flashes. These warnings are approximate, and the actual time to shutdown may vary significantly. For approximate battery times see the tables on pages 5 and 6. Once these warnings are indicated, immediately complete and save your work to prevent data loss and similar difficulties.
UPS Operation Battery Start NOTE Before using this feature, the UPS must have been powered by utility power at least once. This feature allows you to start the UPS without utility power. After utility power has been unavailable for one minute, press and hold the Output On button until the alarm beeps.
UPS Operation UPS Monitoring UPS monitoring is a standard feature of the AS/400 operating system. QUPSDLYTIM is a timer in the AS/400 that tells the system how long to run on UPS power before shutting down. Each AS/400 system is initially assigned a default value for QUPSDLYTIM.
UPS Operation Using the PPDM The PPDM provides continuous online power for your equipment. With the PPDM, you can replace or upgrade the UPS without losing power to your equipment. Figure 16 shows the operation of the UPS with the PPDM.
Page 68
UPS Operation 5. Switch the circuit breaker on all battery cabinets to the OFF (O) position. 6. Disconnect the battery connector on the UPS rear panel. 7. Remove the UPS. PPDM Bypass Switch Serial Port Y-Cord UPS Cabinet External Battery Connector Power Input Battery...
Page 69
UPS Operation PPDM Bypass Switch Serial Port Y-Cord UPS Cabinet External Battery Connector Power Input Connector Battery Output Connector Battery Cabinet Battery Circuit Breaker Figure 18. UPS with 208V-240V PPDM Rear Panel Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
UPS Operation Reconnecting the UPS Use the following procedure to reinstall the UPS and transfer the critical load from Maintenance Bypass (AC Line operation) to the UPS: 1. Reconnect the battery cabinet to the battery connector on the UPS rear panel. 2.
C H A P T E R 5 OMMUNICATION The UPS is equipped with a communications interface port that allows communication with a wide variety of external devices including: Video or dumb terminal Serial printer Computer with power management or shutdown software AS/400 systems The serial port enables you to monitor and record diagnostic data with the following communication interfaces:...
Communication Front Panel Communications Access Before you access the front panel, review the following configurations and note the indicator that corresponds with the communication mode. NOTE Only the Printer mode front panel options change the baud rate. Use the UPS Serial Communications Menu to select other baud rates (see page 62).
Page 73
Communication To access the front panel communication options, perform the following steps: 1. If the UPS is powered on, prepare your equipment for shutdown. Press and hold the Output Off button until the long beep ceases (approximately three seconds). Unplug the UPS. Wait until all indicators turn off and then continue to the next step.
Communication UPS Serial Communications Menu With the UPS Serial Communications (Main) Menu, you can view or select UPS communication modes, baud rates, and LAN configurations. To change or display the current communications configuration: 1. Connect the UPS serial port to a video monitor with a serial interface or to your computer’s serial port.
Page 75
Communication 8hhyt Æ) 9 $ ! !$! Tr vhy Æ) 7F"("7!&# Wr v Æ) ! 8PHH qr) Tr fQ v 7hq ) G6I qr) Iryy Tvr Ahy 9rrpv) @hiyrq Ir 8PHH) 6T8DD Ir 7hq) Ir G6I) Iryy Q r hpr ih pvr NOTE Catalog #, Serial #, and Version # are all identification numbers unique to your UPS and can also be found on the UPS nameplate.
Page 76
Communication T@G@8U G6I 8PIADBVS6UDPI IPW@GG 6T# " "8PHG6I H6I6B@S 8VTUPH 8PIADBVS6UDPI UP RVDU UCDT H@IV @IU@S T@G@8UDPI 33 Select the AS400 option if you are using OnliSafe software to monitor the UPS. The Custom Configuration option has two screens: the first screen has options available for inverter shutdown, and the second screen has options available for the contact configuration.
Communication allows you to select a new baud rate. The Select Z > Set Baud Rate Baud Rate Menu displays a list of baud rate options. T@G@8U 76V9 S6U@ " !# #' & (% (! RVDU UCDT H@IV @IU@S T@G@8UDPI 33 5.
Communication UPS Communications Interface Port In addition to configuring the UPS for specific communication options, you must also ensure proper use of the serial port when connecting the UPS to your network or monitoring equipment. C A U T I O N The serial port LAN contacts are transistors and are rated at a maximum current of 50 mA and a maximum of +40 Vdc.
Communication Communications Mode Reference Chart The following chart defines the UPS serial port contacts. Serial communication is not available with 3Com and AS/400 network configurations. Use only the applicable pins for the selected communication mode; otherwise, interference problems may occur. Communication Mode Function Signal Name Pin No.
Page 80
Communication This page intentionally left blank. Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
C H A P T E R 6 PECIFICATIONS Prestige UPS Model Specifications 120V Rating Label Watts Input Output Current for 120V Typical Heat Models Model Number Current Loss (nominal) Line Operation 650P1SE 4.9A 5.4A 650 EXT 650P2SE 4.9A 5.4A 1250 EXT 1250P2SE 1250...
Specifications Part Numbers Base Equipment Machine Model IBM Part Watts Volts Frequency Description Type Number 9910 21H8429 110-127 50-60 Prestige 650 9910 21H8430 110-127 50-60 Prestige 650 EXT 9910 21H8433 208-240 50-60 Prestige 650 EXT 9910 21H8432 1250 110-127 50-60 Prestige 1250 EXT 9910 21H8434...
Page 84
Specifications This page intentionally left blank. Powerware Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy ®...
C H A P T E R 7 ROUBLESHOOTING The Prestige UPS is designed for durable, automatic operation and also alerts you whenever potential operating problems may occur. Use the following troubleshooting chart to determine the UPS alarm condition. Indicator Legend Unlit Amber Green...
Page 86
Troubleshooting Condition Possible Cause Action Communications do not Incorrect communications Verify cable integrity (see page 66). function properly. cabling. Incorrect baud rate. Select a new baud rate (see page 65). Incorrect communication mode. Select a new communication mode (see Chapter 5). Power requirements exceed UPS Your UPS continues to operate.
Troubleshooting Condition Possible Cause Action Weak battery while in Normal Allow the battery to charge for 24 hours, mode. The alarm beeps. then retest. Have batteries replaced if condition persists. BATTERY BATTERY Battery breaker is open (O). Verify that the battery circuit breaker is in the ON ( ) position.
Page 88
Troubleshooting This page intentionally left blank. Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
C H A P T E R 8 AS/400 S ERVICE The following sections describe the methods for obtaining service for your UPS and warranty information. Warranty The warranty service on Powerware Corporation UPSs is element exchange. If the UPS becomes inoperative, the module that is inoperative will be replaced.
AS/400 Service Battery Warranty If, in Powerware Corporation’s opinion, the unit fails to meet published specifications and the defect is within the terms of the limited warranty (attached), the defective part(s) will be repaired or replaced at the option of Seller with no charge for replacement parts. The battery is warranted to have at least 70% of original full load capacity at the end of five years from date of installation or 66 months after manufacture, whichever comes first.
AS/400 Service Customer Responsibilities The customer is responsible for the following element exchange items: Receiving, unpacking, and exchanging of the defective element. Repacking the defective element in the container received with the replacement element. Following the instructions provided for return of the defective element.
Page 92
AS/400 Service Handling of Incomplete, Damaged, or Incorrectly Shipped 9910 UPSs If the customer initially receives a 9910 UPS that is incomplete, damaged, or incorrectly shipped: 1. The customer calls IBM at 1-800-IBMSERV to report the problem. 2. An IBM representative notifies the customer of how the problem will be resolved.
Page 93
AS/400 Service EMEA Customer Process for Service 1. Customer calls the local IBM office servicing account. 2. The IBM CE responds, determines the problem, and resolves the problem. IBM Powercare Five-Year Warranty Applies only to electronics (unit) installed in the 50 United States of America, Canada, Latin America, and Asia Pacific: Powerware Corporation warrants the unit against defects in material and workmanship for a period of five years from the date of startup or sixty-six (66) months from the date of completion of manufacture, whichever period expires first.
Page 94
AS/400 Service Powerware Protection Guarantee Attached Equipment Protection Program Terms and Conditions Program Summary: Powerware Corporation guarantees to repair or replace (at the option of Powerware Corporation) any equipment that is damaged by AC power disturbances when said equipment is properly connected to a Powerware Corporation uninterruptible power supply (UPS) covered by the Powerware Protection Guarantee.
NDEX Numeric output connector, 38 storage, 35 3Com Network Interface Battery Fault front panel configuration, 60 condition, 75 LAN Configuration Menu, 64 indicator, 49 Battery Mode, 51 Battery Online, indicator, 49 AC Line Bypass switch, 55 Battery Start, 53 operation, 55 Battery Test on Demand, 52 alarm baud rates, 62, 65...
Page 96
Index Control Keys Control-C, 62 indicators, front panel, 49 Control-E, 63 input cord cord, power 120V model, 38, 46, 70 120V model, 38, 46, 70 208V-240V models, 40, 47, 70 208V-240V models, 40, 47, 70 Inverter Shutdown Control, 64 Custom LAN Configuration Menu, 64 LAN Configuration customer service, 77...
Page 97
Index Normal, 50 Printer, 61, 63 Polled Dump Mode, 63 Terminal, 63 Power Management Software VT100 Terminal, 63 LanSafe, 60, 65 OnliNet, 60, 65 OnliSafe, 60, 64 PowerPass Distribution Module (PPDM) Normal Mode AC Line operation, 55 indicator, 49 block diagram, 55 operation, 50 installation, 41 Novell Network Interface...
Page 98
Index serial cable, 66 serial port Terminal Modes, 63 contact ratings, 66 Tests description, 66 Battery (on demand), 52 diagnostic, 52 service for incomplete, damaged, or transistors, contact ratings, 66 incorrect UPS, 80 troubleshooting in Asia Pacific, 80 chart, 73 in Canada, 80 tips, 48 in EMEA, 81...
Page 99
Index startup 120V model, 38, 46 208V-240V models, 39, 47 storage, 35 unpacking and inspection, 35 UTIL_FAIL, 64 Utility Out of Spec, 74 volt-amperes, 2 VT100 Terminal Mode, 63 warranty battery, 78 IBM five-year, 81 Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
Page 100
Index This page intentionally left blank. Powerware ® Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy...
Page 101
Powerware Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy ®...
Page 102
164200289 E Powerware Prestige Series Installation and Operator’s Manual for IBM Applications (650 VA - 1500 VA) Uncontrolled Copy ®...