RM3-400/410/420 Series
Installation and Operation Guide
Issue: IPN 997-00012-62E
Issue Date: June 2010
Refer to the separate SC200 or SC100 system controller handbook for full
details of the system controller operation -
www.powerquality.eaton.com/DC-Manuals.
Eaton Corporation
Telecommunications Power Solutions
www.eaton.com/telecompower
DCinfo@eaton.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RM3-400-0330 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton RM3-400-0330

  • Page 1 RM3-400/410/420 Series Installation and Operation Guide Issue: IPN 997-00012-62E Issue Date: June 2010 Refer to the separate SC200 or SC100 system controller handbook for full details of the system controller operation - www.powerquality.eaton.com/DC-Manuals. Eaton Corporation Telecommunications Power Solutions www.eaton.com/telecompower DCinfo@eaton.com...
  • Page 2 The information contained in this literature is subject to change without notice. Subject to the right to use its equipment, Eaton Corporation does not convey any right, title or interest in its intellectual property, including, without limitation, its patents, copyrights and know-how.
  • Page 3: About This Guide

    Please use this email address to report any problems you find in this guide: Eaton DC Product Marketing Communications EMAIL: DCMarketingNZ@eaton.com For Further Information and Technical Assistance For further information and technical assistance see Worldwide Support on page 79. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 4 RM3-400/410/420 Series Installation and Operation Guide Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 5: Table Of Contents

    Task 3 - Connect to the AC Supply..................29 Task 4 - Configuring the dc power system (some models only)........30 Task 5 - Applying Power to the dc-powered Equipment ..........31 Start-Up Completed ....................... 31 Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 6 Appendix D Equipment and Tools Safety Equipment...........................71 Essential Tools ..........................71 Recommended Tools ........................71 Spare Parts ..........................72 Purchasing Information ........................72 Appendix E Circuit Diagrams Equipment Incident Report Worldwide Support Index Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 7: Overview

    Chapter 1 General Description General Description Overview Topic Page RM3-400/410/420 Series DC Power Systems Rectifiers System Controller (RM3-410 and RM3-420 Models only) Other Features Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 8: Rm3-400/410/420 Series Dc Power Systems

    Models with a system controller have an internal input/output (I/O) board. See details on • page 67. An external SiteSure-3G I/O module can be connected to models with an SC200 system • controller. See details on page 21. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 9: Front Views

    Voltage feed module with socket for connection to an extension power shelf (see details on page 23) or an optional SiteSure-3G I/O module (SC200 only, see details on page 21). Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 10: Rear View

    Top: APR48-ES Bottom: APR24-3G and APR48-3G Power On LED (Green) Minor Alarm LED (Yellow) Major Alarm LED (Red) Serial Number Retaining Screw. Tighten to 1.5Nm (13.3 inch-pounds). Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 11: System Controller (Rm3-410 And Rm3-420 Models Only)

    Critical/Major alarm LED (red) Color LCD Soft keys (2) Navigation keys (4) USB 1.1 connector (12Mb/s) Retaining screw Power and system communications connector RS232 connector Ethernet connector and status LEDs Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 12: Sc100 System Controller

    DCTools Configuration Software. Latest version is available free from • www.powerquality.eaton.com/downloads. PowerManagerII Remote Control and Monitoring Software. Contact your Eaton dc product • supplier for further information (see Worldwide Support on page 79). Recommended web browsers (SC200 only): Microsoft Internet Explorer 8 (IE6 is compatible •...
  • Page 13: Other Features

    To ensure reliable operation Mid-point Monitoring operates only when the battery is in float charge and after a configurable lockout period since the last battery discharge, Fast Charge, Equalize or Battery Test. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 14: Battery Time Remaining

    (constant current) load. For details refer to Battery Time Remaining in the SC200 or SC100 System Controller Operation Handbook (see Related Information on page i). Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 15: Chapter 2 Preparation

    Chapter 2 Preparation Preparation Overview Topic Page Warnings Inspecting the Equipment and Reporting Damage Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 16: Warnings

    • Do not attempt to disassemble faulty rectifiers. Return them (in their original packaging) with a completed Equipment Incident Report on page 77. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 17: Inspecting The Equipment And Reporting Damage

    EMC Compliance • This Eaton product ("the equipment") has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the Federal Communications Commission (FCC) Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 18 RM3-400/410/420 Series Installation and Operation Guide Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 19: Overview

    Task 7 - Interconnect RM3-400 (if used as an extension power shelf) Task 8 - Connect the Output Cables Task 9 - Connect to the AC Supply Point Installation Completed Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 20: Installation Tasks

    Interface Board (see the diagram on page for location). The High VAC alarm signal lines must be isolated from the ac supply by a voltage- free relay contact. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 21 If the curve of an upstream ac supply-disconnect device crosses the curve for the rectifier fuse there may not be adequate discrimination. Contact your Eaton dc product supplier for advice (see Worldwide Support on page 79).
  • Page 22: Task 2 - Move Mounting Brackets (If Required)

    Step 1 - Remove brackets Remove top cover. Undo the screws holding each bracket. Remove the brackets and internal plates. Step 2 - Fit 23-inch mounting brackets (if required) Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 23: Task 3 - Mount The Rm3-400/410/420 In The Rack

    Above/below: No restriction Step 2 - Mount the RM3-400/410/420 Fit cage nuts in the correct positions to match the screw holes in the RM3- 400/410/420 rack mounting brackets. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 24 Tighten terminal to 3.9 - 4.5Nm (35 - 39 inch-pounds). • Terminate the Protective Earthing Conductor at a point connected to the protective earth wire in the building. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 25: Task 4 - Connect Input/Output Cabling (Some Models Only)

    See the diagram on page 3. Feed the patch cable through the I/O cable entry hole ready to be connected to the extension power shelf (see details on page 23). Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 26 Controller Operation Handbook. RM3-410/420 with top cover removed. Alarm relay (digital output) terminals (push- connect type). Digital input terminals (push-connect type). Step 4 - Replace the top cover Procedure complete Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 27: Task 5 - Connect Optional External I/O Module (Some Models Only)

    Connect the cable to socket YH11 on the SiteSure-3G module. Step 3 - Replace the top cover Procedure complete For details on setup refer to the SiteSure-3G Installation Guide. See Related Information on page Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 28: Task 6 - Connect Mid-Point Monitoring (If Required - Sc200 Only)

    Step 2 - Connect sense wires to batteries The Mid-point Monitoring sense wires must have short-circuit protection fitted close to the battery terminals. Use the Battery Mid-point Monitoring kits from Eaton (see Spare Parts on page 72) or equivalent. Connect a Mid-point Monitoring sense wire to the middle interconnecting link on each string of batteries (see following diagram).
  • Page 29: Task 7 - Interconnect Rm3-400 (If Used As An Extension Power Shelf)

    410 or RM3-420 dc power system are connected in parallel. The rectifier communications of an RM3-400 and an RM3-410 or RM3-420 dc power system must not be connected if they are supplying separate dc-powered equipment. Procedure complete Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 30: Task 8 - Connect The Output Cables

    Close the dc terminal cover. Negative output cable Positive output cable Step 3 - Connect the cables at the equipment to be powered Follow the instructions provided by the equipment supplier/manufacturer. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 31: Task 9 - Connect To The Ac Supply Point

    Do not switch on the ac supply at this stage. Installation Completed Installation of the RM3-400/410/420 is now complete. Follow the instructions in Start-Up on page to make the system operational. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 32 RM3-400/410/420 Series Installation and Operation Guide Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 33: Overview

    Task 3 - Connect to the AC Supply Task 4 - Configuring the dc power system (some models only) Task 5 - Applying Power to the dc-powered Equipment Start-Up Completed Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 34: Start-Up Tasks

    Check the rectifier's rear connector is correctly aligned with the shelf connector, or damage may occur. Tighten the retaining screw to 1.5Nm (13.3 inch-pounds). This will locate the rectifier in its rear connector. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 35: Task 2 - Pre-Power-Up Checklist

    The system controller will turn on (green Power On LED is on) when the rectifiers start. • When the system controller has completed its start-up sequence (rectifiers are • registered) the rectifier yellow alarm LEDs will turn off. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 36: Task 4 - Configuring The Dc Power System (Some Models Only)

    Other configuration settings can be changed after all Start-Up tasks are complete. For details on how to customize the system's configuration see System Operation in the System Controller Operation Handbook (see Related Information on page i). Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 37: Task 5 - Applying Power To The Dc-Powered Equipment

    SC100 system controller. For full details on how to customize the system configuration settings, and how to setup the remote communications options refer to the System Controller Operation Handbook (see Related Information on page i). Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 38: Ipn 997-00012-62E June

    RM3-400/410/420 Series Installation and Operation Guide Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 39 Configuration File Starting the SC200 or SC100 SC200 or SC100 Operation using the Keypad and Screen SC200 or SC100 Operation Using a PC/Laptop SC200 or SC100 Identity Information Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 40: Configuration File

    System Snapshot (*.dcs): Configuration file including site specific settings. • Configuration (*.dcc): Configuration file without site specific settings - Site Identity, IP • Address, S3P Address, battery characterization data). Click Proceed to Backup the configuration. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 41: Starting The Sc200 Or Sc100

    System Controller If Logon is required see Operation Handbook. All Keypad Access Security on active Critical, Major, page 36. Minor and Warning alarms are displayed. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 42: Sc100

    Keypad access is Read Only, or PIN Protected and the keypad access PIN is lost. The SC200 will continue to function, but no configuration changes can be made. Contact your Eaton dc product supplier or Eaton for advice (see Worldwide Support on page 79).
  • Page 43: Alarm Indicators

    Visual indicators Power on LED (green) Minor Alarm LED (yellow) Critical/Major Alarm LED (red) The system value cannot be displayed because of a failed, disconnected or unconfigured sensor. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 44: Sc200 Or Sc100 Operation Using A Pc/Laptop

    SC200 or SC100 Operation Using a PC/Laptop DCTools is configuration software for editing a system controller's configuration file (on-line) and monitoring the operation of Eaton's dc power systems. It is available free from www.powerquality.eaton.com/downloads. Using DCTools via USB (SC200 only) DCTools can be run on a PC/laptop connected to the SC200's USB port.
  • Page 45: Using Dctools Via Rs232

    For remote PC/laptop connection details see Communications Options in the System Controller Operation Handbook. Before you start you will need: The latest version of DCTools available from: www.powerquality.eaton.com/downloads. • A PC/laptop with RS232 port and DB9 F/F Null-modem cable (RadioShack 55010600, •...
  • Page 46: Sc200 Or Sc100 Identity Information

    (factory set). Identity SC200: Settings > Info Software Version The version of the embedded DCTools/Web: (App Version) software in the SC200 or SC100 Configuration > Identity (factory set). Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 47 Any notes relevant to site access, location or other matters. Contact Contact name, phone number, and so Configuration Reference name of the configuration Name file in the SC200 or SC100. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 48 RM3-400/410/420 Series Installation and Operation Guide Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 49: Chapter 6 Maintenance

    Eaton. This includes disassembly and/or servicing of any modules. • For further information on Servicing contact your local Eaton dc product supplier, or refer to the contact details on page 79. Topic Page...
  • Page 50: Troubleshooting

    Check rectifier comms bus wiring. If second rectifier registers, then first rectifier is faulty and must be returned for service. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 51 Install additional rectifiers. and rectifier yellow LEDs capacity. are on (rectifiers are in Battery is recharging after ac Check battery has recharged within current limit). supply failure. expected time. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 52 Monitoring system has detected page 56. a voltage imbalance in one of the battery strings. A Battery Mid-point Monitoring Check the sense wires. sense wire is disconnected. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 53: System Controller Problems (Rm3-410/420 Models Only)

    Incorrectly configured shunt Check shunt mapping and gain is correct. inputs. Current is within the Battery None, normal operation. State Threshold. See details in the System Controller Operation Handbook. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 54 DCTools not installed on PC or Install latest version of DCTools. wrong version. Download from www.powerquality.eaton.com/downloa Password required to change See Write Access Password in the System settings. Controller Operation Handbook. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 55 Check S3P Access is enabled. See details are disabled. in the System Controller Operation Handbook. Password required to change See Write Access Password in the System settings (using DCTools or Controller Operation Handbook. PowerManagerII). Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 56 SC200 time can be set, but is Internal battery is dead. Return SC200 for incorrect when SC200 restarts. service. (If removed, the battery must be disposed of according to the manufacturer's instructions.) Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 57: Replacing Or Adding A Rectifier

    Step 3 - Replace rectifier or fit blank panel Insert a replacement rectifier into the empty slot (see details in following section), or fit a blank panel. Procedure complete Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 58 Check that the rectifier’s Power On LED turns on (after the startup delay) and the alarm LEDs turn off. The rectifier will automatically register with the system controller and download its operating parameters. No adjustments are required. Procedure complete Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 59: Replacing The System Controller (Some Models Only)

    • contact your Eaton dc power system supplier to obtain a master configuration file to • suit the dc power system. This file will have to be customized for the site.
  • Page 60: Replacing The Input/Output Board (Some Models Only)

    *See Communications Options in the System Controller Operation Handbook. A replacement input/output board. • An anti-static wrist strap to prevent damage to the static sensitive components on the • input/output board. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 61 SC200 only: Connect a PC/Laptop with a web browser to the system controller via an IP network. See Communications Options in the system controller Operation Handbook (see Related Information on page i). Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 62: Battery Mid-Point Monitoring (String Fail) Alarm (Sc200 Only)

    If the alarm is still present then follow the battery manufacturer’s instructions on servicing or replacing the faulty cell/monobloc. After the faulty cell/monobloc has been serviced or replaced clear the alarm (see Step 3). Procedure complete Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 63: Appendix A Specifications

    120V ac: 2.4kW 208-240V ac: 4.0kW Output Power (maximum) with APR48-3G Rectifiers, 48-58V RM3-400 models: 120V ac: 3.3kW 208-240V ac: 5.4kW RM3-410/RM3-420 models: 120V ac: 2.2kW 208-240V ac: 3.6kW Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 64 All models 1U, 19" or 23" mounting, 13.2" [335 mm]* * Additional clear air space is required at rear for rectifier exhaust air venting. See details on page 17. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 65 2.53V to 3.43V (-20 to +70°C [-4 to +158°F]) Resolution < 0.01V (< 1°C [1.8°F]) Accuracy ±1°C [1.8°F] at 25°C [77°F], ±2°C [3.6°F] over rated temperature range Maximum Cable Length 20m (65 feet) Connector RJ45 Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 66 Mozilla Firefox 3.0. External modem options Type: PSTN or GSM Operation: Dial in/Dial out on alarm* * Can operate as a backup for Ethernet communications (SC200 only). Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 67: Controller Menus

    At each menu screen press Enter to access the associated configuration menu screen(s). These menus have multiple configuration menu screens. See details in the System Controller Operation Handbook. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 68: Sc100 Menu

    Any active alarms are displayed in rotation. Operate control processes. Scroll to show any other rectifiers. SC100, I/O board and rectifier identity information. List of any active alarms. Configure control processes. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 69: Appendix C Connector Pin-Outs

    RXP System +24/48V (System bus voltage) Communications +24/48V (System bus voltage) RS485-A RS485-B USB B USB Serial Interface VCC (+5 V dc) (SC200 only) Data - Data + Ground Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 70 RM3-400/410/420 Series Installation and Operation Guide RS232 D9M and RJ45 connector pin-outs RJ45 plug pin-outs Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 71: I/O Board (Iobgp-00, -01) Connector Pin-Outs

    XH12A Battery Mid-point String 1 Mid-point Monitoring sense inputs String 2 Mid-point (SC200 only) String 3 Mid-point String 4 Mid-point XH15A Digital inputs D1-D3 D1 input D2 input Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 72 AC Distribution Fan Fail AC Distribution MOV Fail 0V out (system live - protected) System common - protected YH11 RJ45 RXP System +24/48V (System bus voltage) Communications +24/48V (System bus voltage) Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 73: Input/Output Board (Some Models Only)

    Relay outputs: 6 (one also used as Monitor OK alarm) For input and output specifications see details on page 59. For connector pin-outs see details on page 65. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 74 Power and RXP comms input - YH11 XH15B Not used Digital (relay) outputs RY1-RY6 (6) - XH16-XH21 Not used Not used Battery Mid-point Monitoring sense inputs (SC200 Not used only) Not used Not used Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 75: Connections

    (SC200 only). Connect to S1/S2 via RJ45 splitter if I/O board fitted. For connector pin-outs see details on page 65. For input and output specifications see details on page 57. Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 76 RM3-400/410/420 Series Installation and Operation Guide Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 77: Equipment And Tools

    • page 72. DCTools software (download from www.powerquality.eaton.com/downloads). • Test load (to suit maximum output of dc power system) • Labeling tool and labels • Clamp-on ammeter • Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 78: Spare Parts

    Battery Mid-point Monitoring connection kit Eaton MPTLOOM-3300 (2 x 3m sense wires), or for use with SC200 (for two battery strings) Eaton MPTLOOM-7600 (1 x 7m, 1 x 6m sense wires) Purchasing Information Eaton See contact details on page 79.
  • Page 79: Appendix E Circuit Diagrams

    Appendix E Circuit Diagrams Circuit Diagrams Drawing Issue Title Number 3692996 WIRING DIAGRAM RM3-X00 (applies to RM3-400 models) 3692979 WIRING DIAGRAM RM3-X2X (applies to RM3-410/420 models) Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 80: Ipn 997-00012-62E June

    RM3-400/410/420 Series Installation and Operation Guide Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 81 Circuit Diagrams Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 82 RM3-400/410/420 Series Installation and Operation Guide Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 83: Equipment Incident Report

    Please enter as much information as you can. Send the completed form, together with the item for repair to your nearest authorized service agent. NOTE: Only one fault to be recorded per form. For further information contact your local Eaton dc product supplier or Eaton (see contact details on page 79). Or email: CustomerServiceNZ@eaton.com...
  • Page 84 ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ SG/03 ISS06 Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 85: Worldwide Support

    Worldwide Support Worldwide Support For product information and a complete listing of worldwide sales offices, visit Eaton's website at: www.eaton.com/telecompower or email: DCinfo@eaton.com For technical support contact either your local Eaton dc product representative, the closest office from the following list, telephone (+64) 3 343-7448, or email CustomerServiceNZ@eaton.com...
  • Page 86 RM3-400/410/420 Series Installation and Operation Guide Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 87: Index

    Time Remaining • 8 Blank Panel • See Spares Browsers (recommended) • 6 EMC Compliance • 11 Ethernet Connector • 5, 69 Circuit Diagram • 73 Ethernet Communications • 7, 49 Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 88 Rectifier blank panel • 51 Low Voltage Disconnect (LVD) Rectifier Current • 35 Connectors • 65, 67 Rectifier Fuses • See AC Discrimination LVD Alarms • See Troubleshooting Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...
  • Page 89: Index

    Servicing • 11, 77, 79 SMS Text Messaging • See GSM Modem Communications SNMP • 7 SNTP • See Internal Clock Software Versions • 6 Sound • See Audible Alarm Indication Copyright © 2007-2010 Eaton Corporation. All Rights Reserved. IPN 997-00012-62E June 2010...