Maintenance and cleaning
4.5
Mounting the angle adapter
4.5.1 Dismantling the nozzle and the electrode holder
The standard Corona spray gun is delivered with a fan spray nozzle. The nozzle can be
changed easily, as described in the following.
Caution
When changing from a fan spray nozzle to an angle nozzle, the depth control must be
readjusted!
The angle adapter is necessary to perform the change:
WA90 C4, WA60 C4 or WA30 C4
as it is specified in the accessory list.
Hint
Both a fan spray and a round spray nozzle can be installed in the angle adapter.
2
1
Caution
When pulling out and inserting the electrode holder, ensure that the insert is not
damaged!
•
Remove powder residue from the parts removed and from the spray gun.
01 / 2008
3
•
5
•
•
peac4_0005
0390882
Unscrew the outer nut 1 from the spray gun housing 5 .
Pull the fan spray nozzle 2 off the electrode holder 3 .
Carefully pull the electrode holder 3 out of the spray
gun housing 5 .
-
PEA-C4-HiCoat FM
0405_Umbau_zurwinkeldüse.doc
030301_ .doc
23