Fitting The Round Spray Nozzle - WAGNER PEA-C4-HiCoat FM Operating Manual

Automatic powder spray gun
Table of Contents

Advertisement

4.4

Fitting the round spray nozzle

The standard Corona spray gun is delivered with a fan spray nozzle. The nozzle can be
changed easily, as described in the following.
Caution
When changing from a fan spray nozzle to a deflector cone, the depth control must be
readjusted!
The electrode holder C4 R FM is necessary to perform the change.
2
1
Caution
When pulling out and inserting the electrode holder, ensure that the insert is not
damaged!
Remove powder residue from the parts removed and from the spray gun.
Caution
Be careful when mounting the electrode holder C4 R FM.
Otherwise there is a risk of injury by the electrode tip.
6
7
7
1
8
peac4_0008
The spray gun is ready for use again.
22
3
5
peac4_0005
5
X
Y
0390882
Unscrew the outer nut 1 from the spray gun housing 5 .
Pull the fan spray nozzle 2 off the electrode holder 3 .
Carefully pull the electrode holder 3 out of the spray
gun housing 5 .
• Carefully fit the new electrode holder C4 R FM 6
into the spray gun housing 5 .
• Slide the deflector cone sleeve 7 onto the electrode
holder 6 .
• Align the marks X and Y .
• Fasten in place using the outer nut 1 .
• Slide the deflector cone 8 back over the deflector
cone sleeve 7 .
-
PEA-C4-HiCoat FM
Maintenance and cleaning
040401_FM.doc
030301_ .doc
040402_FM.doc
01 / 2008