Grounding - WAGNER PEA-C4-HiCoat FM Operating Manual

Automatic powder spray gun
Table of Contents

Advertisement

Caution
The distance of the installed spray guns to each other must be at least 300 mm .
Fit the spray gun to the hanger and fasten both, for example, to the gun mounting on the
reciprocator.
Connect the spray gun to the high voltage generator using the electrical cable E .
Connect the hose for the powder feed P to the spray gun.
Connect the hose for the atomizing air A to the spray gun.
Hint
Using a Wagner powder injector PI-F1 and a suitable control unit, it is possible to
automatically blow out or purge the angled spray gun each time prior to switch off.
2.3

Grounding

For safety reasons, the spray gun must be properly grounded. This occurs through the gun
mounting.
Good grounding of the workpiece is also necessary for optimum powder coating.
A poorly grounded workpiece causes:
dangerous electric charging of the workpiece
back-spray onto spray gun and user
uneven coating
very bad wrap around
Warning
Sparks between workpiece and conveyor hooks (hangers) can occur if hooks or
other hanger parts are not completely cleaned!
These sparks can cause heavy radio frequency interference.