Siemens S6 GSM Service Manual

Siemens S6 GSM Service Manual

Private communication systems mobile phones
Hide thumbs Also See for S6 GSM:

Advertisement

Quick Links

Private Communication Systems
Mobile Phones
Service Manual
S6 GSM / PCN
V 1.3
Total number of pages: 31
V1.3
1
PN MP ST
D. Schnoor
10/97

Advertisement

Table of Contents
loading

Summary of Contents for Siemens S6 GSM

  • Page 1 Private Communication Systems Mobile Phones Service Manual S6 GSM / PCN V 1.3 Total number of pages: 31 V1.3 PN MP ST D. Schnoor 10/97...
  • Page 2: Technical Data

    Private Communication Systems Mobile Phones Table of Contents Technical Data Length 159 mm Width 55 mm Thickness 16/22 mm Volume 155 cm³ Weight 165 g Performance: GSM class 4 (2 Watt) PCN class 1 (1 Watt) Powersupply: Lithium Ion battery (3,6V/1000mAh) Standby time: up to 30 hours Talk time: Up to 4 hours.
  • Page 3: Mechanical Concept

    Private Communication Systems Mobile Phones Mechanical Concept Note: All part numbers refer to mechanical drawing in section 4.1! The S6 consists of two boards, the RF & Control module (1010) and the user interface (1020). The connection between those two boards is not made by a normal connector with plug-in contacts, but by a special interconnector (1090) embedded into a shielding frame (1060).
  • Page 4 Private Communication Systems Mobile Phones S6 GSM / PCN mechanical drawings Figure 1: Mechanical Drawing S6 V1.3 PN MP ST D. Schnoor 10/97...
  • Page 5 Private Communication Systems Mobile Phones Figure 2: Display with Dust Protection Frame Note: The numbers displayed in the above drawings are NO ORDERING Nos, use the numbers in chapter 11 for ordering! Ordering number for dust protection frame: L36859-A4-C141 Figure 3: Dust Protection Frame V1.3 PN MP ST D.
  • Page 6 Private Communication Systems Mobile Phones Disassembling the S6 ESD regulations have to be followed! 1. Remove battery and SIM-Card. 2. Unscrew antenna (1130). 3. Unscrew 2 oval head screws (1150) (Torx 1,8x12). 4. Turn out 2 short flat head screws (1140) (Torx 1,8x8). 5.
  • Page 7 Private Communication Systems Mobile Phones ESD regulations have to be followed! 1. Put earphone capsule (1120) and microphone (1110) into upper case shell. 2. Insert keypad (1030) into upper case shell (1040). 3. Put dust protection frame (1210) on display window inside upper case shell. 4.
  • Page 8 (see table below!) If a bolted handset comes back for service and one of the boards is defective, do not try to separate them. Just send the whole sandwich back to Germany. S6 GSM/PCN Board Versions GSM: PCN: Old version (with bolt):...
  • Page 9 Handset Datecodes Siemens is using the industrial standard DIN EN 60062 to indicate the production / service dates. The code is printed on the IMEI sticker located under the simcard reader. -> YY = Datecode V1.3...
  • Page 10: Hardware Concept

    Private Communication Systems Mobile Phones The first character of the datecode indicates the year of production: F = 1995 H = 1996 J = 1997 The second character indicates the month of production: 1-9 = january to september O = october N = november D= december Example: HD means that the set was produced in december of 1996.
  • Page 11 Private Communication Systems Mobile Phones V1.3 PN MP ST D. Schnoor 10/97...
  • Page 12 Private Communication Systems Mobile Phones Hardware Description The handset consists of five major integrated circuits: 1) GOLD-µC (PMB 2706) This microprocessor is responsible for controlling the keyboard, SIM-Card, EEPROM, Flash and RAM. Furthermore it interfaces the GOLD-SP (PMB 2707), controls the power up/power down of the RF module and sets the amplification of the PA.
  • Page 13: Power Supply Concept

    Regulator Control RF Supply +6.5 V Linear +2.8 V Power Regulator Control Logic Supply Ignition S6 GSM/PCN SIM Supply Power Supply Watchdog ASIC ON_OFF Button RESET Power Detection Charging On (to µP) (from µP) From the 3.6 V battery voltage, all other supply voltages of the S6 are derived, controlled by the power supply ASIC.
  • Page 14: Overvoltage Conditions

    -> Be careful with foreign accessories or chargers! -> Make sure that the charging current is limited to a value below 1A! S6 GSM / PCN Software Options The following list will help you to understand what the different software options are for and how they are used.
  • Page 15 Private Communication Systems Mobile Phones OPTIONS RINGER Ringer On / Off The ringer can be switched on or off Volume Adjust The ringer volume can be adjusted Tone Adjust The ringer tone can be adjusted DIVERT If not Reachable Clear / Set / Check Divert when the phone is switched off If no Reply Clear / Set / Check...
  • Page 16 Private Communication Systems Mobile Phones Allow last 1-5 Set / Clear PHONECODE This will limit all outgoing calls to the numbers stored in the redail list (maximum five numbers!) Call Screening Set / Clear PHONECODE This feature will filter the incoming calls. If a call comes in which number is stored in the phonebook, the phone will ring.
  • Page 17 Private Communication Systems Mobile Phones All Calls In Set / Clear PASSWORD No incoming calls possible When Roaming Set / Clear PASSWORD No incoming or outgoing calls when roaming MESSAGES Voice Message Alter / Hear You can save the telephone number of your voice mailbox to hear your messages ..Text ( x old )
  • Page 18 Private Communication Systems Mobile Phones called party (CLIR) Power Save Mode On / Off Periodic location update will be delayed to save energy TIME CHARGE Last Call Length and cost of last call Total Calls Clear (PHONECODE) Lenght and cost of all calls Auto Display On / Off Automatic lenght and cost display...
  • Page 19 Private Communication Systems Mobile Phones SET UP DTMF Key Tone On / Off DTMF for remote control of answering machines etc. Key Sound Click / Tone / Silent Any Key Answer On / Off Any key will hook off Illumination On / Off Switch off illumination permanently to save energy...
  • Page 20: Software Programming

    Private Communication Systems Mobile Phones Software programming The software of the S6 GSM / PCN handsets is programmed directly from a PC using the bootadapter (see drawing below). Bootadapter RS-232 Connection Cable AC-Adapter Description of software booting Connect COM-port of PC with bootadapter using the enclosed RS232 cable.
  • Page 21: Language Groups

    Private Communication Systems Mobile Phones Language Groups There are different language groups of the same software version: Attention: This information is subject to change! Contact your service coordinator for the latest update and ordering numbers. a) GSM Language Group Display Languages German, English, French, Italian Danish, Finish, Swedish, Norwegian English, Katalanish, Spanish, Portuguese...
  • Page 22 The unblocking code is derived from the IMEI number and can only be calculated by our hotline personell in Germany. If you need unblocking codes just send a fax with the IMEI numbers to: Siemens AG PN KE SH World Service Center...
  • Page 23: Specification

    Private Communication Systems Mobile Phones Battery Specification The S6 battery is a Lithium-Ion type with a voltage of 3.6 Volts and a capacity of 1000 mAh. The connections BATT+ and GND are used to supply the mobile, while RCODE is used to detect the battery technology.
  • Page 24 Private Communication Systems Mobile Phones Short Circuit Protection The battery is short-circuit protected by an electronic fuse. The resetting of the fuse can be done by the following procedures: * Plug the battery into the desktop charger. * Apply +5 Volts between the BATT+ and GND contacts (see drawing!) Limit the current to 10mA.
  • Page 25 Private Communication Systems Mobile Phones S6 GSM / PCN Accessories Depicted are the following accessories: V1.3 PN MP ST D. Schnoor 10/97...
  • Page 26: Desktop Charger

    Private Communication Systems Mobile Phones Desktop Charger This charger can be used to charge the battery alone or the battery inserted into the handset, but not both at the same time! Furthermore ist is helpful to reset disabled batteries. The desktop charger is supplied by the AC-adapter coming with the handset. Car Charger The car charger is connected to the cigarette lighter of the car with a flexible cable.
  • Page 27: Spare Parts List

    The connections to the battery are made directly using the cables with fuses for „battery+“, „battery-“ and „ignition“. Furthermore it provides a „radio mute“ connection to the car radio. See drawing „S6 GSM / PCN Accessories“ for details- Spare Parts List V1.3 PN MP ST D.
  • Page 28: Swap Units

    Q.p.P. L24859-C2600-A910 S6/GSM/SWAP/LG 1 L24859-C2600-A914 S6/GSM/SWAP/TIM/LG 1 L24859-C2600-A915 S6/GSM/SWAP/OPI/LG 1 L24859-C2600-A917 S6/GSM/SWAP/TDM/SIM-LOCK L24859-C2600-A922 S6/GSM/SWAP/MOVISTAR/SIM-LOCK L24859-C2600-A923 S6/GSM/SWAP/AIRTEL/SIM-LOCK L24859-C2600-A924 S6/GSM/SWAP/SIEMENS/LG 7 L24859-C3600-A910 S6/PCN/SWAP/LG 1 L24859-C3600-A914 S6/PCN/SIM-LOCK/ADAM/SWAP/LG 1 L24859-C3600-A915 S6/PCN/SIM-LOCK/MUTIA/SWAP/LG 2 LG = Language Group spare parts Part.-No. Parts Q.p.P. L24859-A2600-A905 S6/GSM/RF/CONTROL/BOARD/ LG1 V1.3...
  • Page 29: Customer Spezified Spare Parts

    Private Communication Systems Mobile Phones L24859-A3600-A905 S6/PCN/RF/CONTROL/BOARD/LG1 L24851-F1000-A20 CONNECTION-BOX/+LOUDSPEAKER L36158-A4-B2 LOWER/CASE/SHELL/STD/COMPLETE L36158-A4-C8 FOAM/SEAL/BUZZER L36158-A4-C11 COVER/RUBBER/SCREW L36158-A4-C27 SCREEN/FRAME L36212-Z3-C15 ACOUSTIC/EARPHONE L36254-Z6-C59 MICROPHONE/GSM/PCN L36334-Z93-C253 INTERCONNECTOR L36851-Z1361-B18 BATTERY CONTACT 4pins L36851-Z1402-A10 KEYPAD/GSM/PCN L36851-Z1508-A17 S6/GSM/USER INTERFACE L36851-Z1508-A18 S6/PCN/USER INTERFACE customer spezified spare parts L36158-A4-B1 UPPER/CASE/SHELL/GSM/STD L36158-A4-B11 UPPER/CASE/SHELL/PCN/STD...
  • Page 30 Private Communication Systems Mobile Phones L36158-A5-B1 HOLDER/HANDSET L36158-Z27-A212 SCREW/FLAT/HEAD/TORX 1,8x12 L36158-Z28-A312 SCREW/OVAL/HEAD/TORX1,8x12/HANDSET/ *) L36254-Z6-C61 HANDSFREE/MICROPHON/GSM/PCN L36851-Z1303-A134 CON.CABLE/CARKIT/HF L36158-A2-C5 DISTANCE/STRIP *) L36158-A5-C4 PLUG-IN/CONSOLE *) L36158-A5-C5 PLUG-IN/COVER *) L24851-Z2630-A2 DESK-TOP/CHARGER #) L36851-Z2618-V1 PLUG-IN/POWER-SUPPLY/EU L36851-Z2618-V2 PLUG-IN/POWER-SUPPLY/UK L36851-Z2618-V3 PLUG-IN/POWER-SUPPLY/AUS L36851-Z2618-V4 PLUG-IN/POWER-SUPPLY/TAIWAN #) Plug-In power supply not included *) only for handsfree carki Documentation L36859-N2600-A100-*-4-E19...

This manual is also suitable for:

S6 pcn

Table of Contents