Description And Use Of Motor-Driven Pump; Specifications - EBARA DL Operating And Maintenance Instructions Manual

Submersible motor-driven pumps
Hide thumbs Also See for DL:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
5.2. PROTECTION AND SIGNIFICANT CAUTION
All live wires or parts are electrically isolated
from the earth. However, there is an additional
safety feature, which composes of all accessible
conducting parts being connected to an earth wire
so that these parts cannot become hazardous
if the main isolating system fails.
5.3. RESIDUAL RISKS
A residual risk of entering into contact (even if
not accidentally) with the rotor in the suction
port exists due to pump construction.
The residual risk exists in models with thermal
motor protection, that once the trip has activated,
the pump may restart without notice once
the motor has cooled to within the required
operating temperature limits.
6. DESCRIPTION AND USE
OF MOTOR-DRIVEN PUMP
6.1. DESCRIPTION
SUBMERSIBLE MOTOR-DRIVEN
Name
PUMPS
DML-DMLV
Model
DL-DL/WC
(see Nameplate)
DS
DVS
6.2. USE FOR WHICH PUMPS ARE DESIGNED
Motor-driven pumps are designed to:
-
Movement of water as described in paragraph 7.1
-
Movement of dirty or sewage water with solids in
suspension as described in paragraph 7.1;
-
Emptying cesspits, sceptic tanks, trenches, etc.
6.3. USE FOR WHICH PUMPS ARE NOT DESIGNED
Motor-driven pumps are not designed to:
-
pump liquids other than water;
-
pump water containing acids or alkalis, and corrosive
liquids in general;
-
pump seawater;
-
pump flammable liquids and hazardous liquids in
general;
-
enter into contact with food products;
-
be used in structures designed for living organisms
(pools, aquariums, fish farms, etc.);
-
be used in significantly important systems (computer
cooling or refrigeration systems, etc.):
-
be used in outdoor environments if equipped with
power cord under 10 m long;
-
be used for purposes other than those described in
Chapter 6.2 "Use for which pumps are designed".
The motor-driven pumps must never be made
WARNING!
to work without liquid.

7. SPECIFICATIONS

The manufacturer reserves the right to modify technical
specifications to improve or update its products without
prior notice.
7.1. SERIES-D PUMP TECHNICAL SPECIFICATIONS
PUMPED LIQUID SPECIFICATIONS
PH
Maximum liquid temperature
Free chloride concentration
Chloride ion concentration
DL, DL W/C
Max solid
Delivery
dimension
Diameter/model
[mm]
Ø 65
Ø 35
Ø 80, Ø 100(80)
Ø 50
Ø 100
Ø 60
Ø 150 (up 22 kW)
Ø 70
Ø 200 (up 22 kW)
Ø 76
Ø 250 (up 22 kW)
Ø 82
Ø 300 (up 22 kW)
Ø 90
all > 22kW
Ø 76
DML/DMLV
Max solid
Delivery
dimension
Diameter/model
[mm]
DML
Ø 76
DMLV Ø80
Ø 80
DMLV Ø100
Ø 100
Max solid
Delivery
dimension
Diameter/model
[mm]
Ø 50
Ø 5
Ø 65
Ø 6
Ø 80
Ø 7
Ø 100
Ø 8
Max solid
Delivery
dimension
Diameter/model
[mm]
50DVS5.75, 51.5
Ø 21
65(80)DVS5.75, 51.5
Ø 33
65(80)DVS52.2, 53.7
Ø 41
5 ÷ 9
0 ÷ 40°C
(without float)
≤ 10 mg/l
≤ 200 mg/l
Max fibre
Max
length
Submersion
[mm]
depth [m]
195
240
300
400
7
500
550
600
500
Max fibre
Max
length
Submersion
[mm]
depth [m]
500
400
7
500
DS
Max fibre
Max
length
Submersion
[mm]
depth [m]
3 (≤1.5 kW)
50
7 (>1.5 kW)
DVS
Max fibre
Max
length
Submersion
[mm]
depth [m]
100
3
200
3
245
7
EN
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dl w/cDmlvDsDvsDml

Table of Contents