Description And Use Of Motor-Driven Pump; Specifications - EBARA Dumper 1 series Operating And Maintenance Manual

Submersible motor-driven pumps
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
5.2. PROTECTION AND SIGNIFICANT CAUTION
All live wires or parts are electrically isolated
from the earth. However, there is an additional
safety feature, which composes of all accessible
conducting parts being connected to an earth wire
so that these parts cannot become hazardous
if the main isolating system fails.
EN

6. DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP

6.1. DESCRIPTION
SUBMERSIBLE MOTOR-DRIVEN
Name
PUMPS
Model
DUMPER
(see data plate)
6.2. INTENDED USE
The motor-driven pumps are intended to move water
containing solids in suspension as described in para. 7.1.
6.3. UNINTENDED USE
Pumps are not suitable for:
-
treating liquids other than water;
-
treating water with a pH not falling into the range
specified at 7.1;
-
treating seawater (with the exception of the versions
in AISI316);
-
treating flammable liquids and hazardous liquids in
general;
-
coming into contact with food products;
-
being used in structures intended for living organisms
(swimming pools, aquariums, fish farms, etc.);
-
being used differently from that specified in paragraph
6.2 "Intended use".

7. SPECIFICATIONS

The manufacturer reserves the right to modify technical
specifications to improve or update its products without
prior notice.
8
7.1. DUMPER SERIES PUMP SPECIFICATIONS
Maximum relative density of liquid treated
pH of liquid treated
Temperature of liquid treated
immersion depth
DUMPER 1(0, 1)
DUMPER 2(0, 1)
DUMPER 3(0, 1) 53.7-S
DUMPER 3(0, 1) 55.5-S
DUMPER 30 57.5-S
DUMPER 3(0, 1) 53.7-M
DUMPER 3(0, 1) 53.7-L
DUMPER 3(0, 1) 55.5-M
DUMPER 3(0, 1) 57.5-M
DUMPER 4(0, 1) 512-S
DUMPER 6(0, 1) 519-S
DUMPER 6(0, 1) 526-S
DUMPER 4(0, 1) 512-M
DUMPER 6(0, 1) 519-M
DUMPER 6(0, 1) 526-M
DUMPER 6(0, 1) 537-M
DUMPER 70
DUMPER 80
7.2. MOTOR SPECIFICATIONS
Pumps with single-phase motor must be piloted
by an electrical panel fitted with start-up and
operating condensers and start-up relay.
Condensers and relay for single-phase motors
Start-up condenser Sc
Operating condenser Rc
Maximum voltage
Start-up relay
Release voltage
Graft voltage
Ratings
Protection from
overheating
Maximum number of
start-ups per hour
Tolerance on
voltage
Tolerance on
frequency
Motors of the DUMPER pumps can be piloted with
inverters/VFD.
1.1
5 ÷ 8
[°C]
0 ÷ 40
minimum
[m]
0.127
maximum
[m]
15
[mm]
Ø 6
[mm]
25x6
[mm]
30x9.5
[mm]
Ø10
[mm]
25.5x5
[mm] 25.5x10
[mm]
Ø 13
[mm]
Ø 15
[μF]
215-259
[V]
220-250
[μF]
35
[V]
370-440
[V]
332
[V]
244-270
[V]
40-90
See plate data
Thermal probe
(to be connected
to the panel)
15
± 6%
± 3%

Advertisement

Table of Contents
loading

Table of Contents