Electrical equipment
Instalación eléctrica
3-flash diagnostic code
If the 3-flash diagnostic code is displayed, check if the anomaly persists after inserting the MASTER key into the
ignition switch.
- If the malfunction disappears when the MASTER key is used, proceed to code the service (black) keys again.
- If the anomaly persists, then the MASTER key and the control unit are not matched. In that case, replace the control
unit and proceed to code the keys.
The immobilizer system is in working order when, after turning the ignition switch to "ON", one 0.7-second flash is
emitted (see chart).
In that case, ignition is possible.
Example - Electronic control unit programmed, transponder
present, key programmed and aerial in working order
Ignition enabled (normal operating conditions)
Código diagnóstico: 3 centelleos
Si se encuentra el código 3 centelleos verificar si la anomalía se manifiesta introduciendo también la llave MASTER
en el conmutador de llave.
- Si la anomalía desaparece utilizando la llave MASTER, efectuar una nueva codificación de las llaves de servicio
(color Negro).
- Si la anomalía persiste, significa que la llave MASTER y la central no están acopladas; en tal caso es necesario
sustituir la central y efectuar la sucesiva codificación de las llaves.
La instalación immobilizer resulta eficiente cuando, después de haber conmutado en "ON", se mide solamente un
centelleo de 0,7 segundos (véase gráfico).
En este caso, el encendido resulta posible.
Ejemplo con central programada, trasponder presente
llave programada y antena funcionante
El encendido está habilitado (condiciones normales
de uso)
4 - 44 1st Update to part no. 594599 X9 125-180 ce 4T 4V
Primera actualización dib. 594599 X9 125-180 ce 4T 4V
1 ' Atualização Des. 594599 X9 125-180 ce 4T 4V
X9 125-180 CC 4T4V
04 014
04 014