230 VAC Wiring Specifications

All 230 VAC clocks include a 9ʼ cord with a three pin earthed plug. If pigtail/hard wiring is required for the application
please refer to 230VAC Digital Clock Wiring.
Receiver Sensitivity (Decode) > 110dBm
l

Surface-mount Installation

Complete the instructions below to install a digital clock/timer directly to the surface of a wall.
Installation
Mount the clock/timer directly to the wall with the two #10 screws and anchors (supplied). To determine the spacing of
the screws, see "Surface-mount Tilt Bracket Mounting Dimensions" on page 19.
NOTE: Most building codes prohibit the use of hard-wired power connections for devices that can be removed
without tools. Clock/timers mounted directly to a wall must have standard power plugs.
Figure 10: Surface Mount Illustration
Primex Wireless
14
XR Classic Series Digital Clock/Timers Installation Guide