Version 2.05; Version 2.05 - Group 0 System Parameters - Delta VFD-VE User Manual

General field oriented vector control drives
Table of Contents

Advertisement

Chapter 4 Parameters

4.2.3 Version 2.05

New or update parameter groups are:
Group 0 System Parameters
Group 2: Digital Input/Output Parameters
Group 3: Analog Input/Output Parameters
Group 5: Motor Parameters
Group 6: Protection Parameters
Group 7: Special Parameters
Group 8: High-function PID Parameters
Group 9: Communication Parameters
Group 10: Speed Feedback Control Parameters
Version 2.05
Group 0 System Parameters
Pr.
Explanation
Content of Multi Function
00-04
Display
Constant/Variable Torque
00-12
Selection
Optimal
Acceleration/Deceleration
00-13
Setting
00-23 Motor Direction Control
4-38
Settings
0: Display output current (A)
1: Display counter value (C)
2: Display output frequency (H)
3: Display DC-BUS voltage ( u )
4: Display output voltage (E)
5: Output power factor angle (n)
6: Display output power (kW)
7: Display actual motor speed (r)
8: Display estimate output torque in N-m (t)
9: Display PG position (G)
10: Display PID feedback in % (b)
11: Display AVI in % (1.)
12: Display ACI in % (2.)
13: Display AUI in % (3.)
14: Display the temperature of heat sink in °C (t.)
15: Display the temperature of IGBT in °C (T)
16: The status of digital input (ON/OFF) (i)
17: The status of digital output (ON/OFF) (o)
18: Multi-step speed (S)
19: The corresponding CPU pin status of digital input (i.)
20: The corresponding CPU pin status of digital output
(o.)
21: Number of actual motor revolution (PG1 of PG card)
(Z)
22: Pulse input frequency (PG2 of PG card) (4)
23: Pulse input position (PG2 of PG card) (4.)
24: Pulse position control for whole operation (MI=37
and MI=ON) (P.)
25: Display the present reel diameter under the
tension control in mm (d)
26: Display the present line speed under the tension
control in m/min (L)
27: Display the present tension setting under the
tension control in N (T.)
0: Constant Torque (150%)
1: Variable Torque (120%)
0: Linear accel./decel.
1: Auto accel., linear decel.
2: Linear accel., auto decel.
3: Auto accel./decel. (auto calculate the accel./decel.
time by actual load)
4: Stall prevention by auto accel./decel. (limited by 01-12
to 01-21)
0: Enable forward/reverse
1: Disable reverse
2: Disable forward
Factory
VF VFPG SVC FOCPG TQCPG
Setting
0
0
0
0

Hide quick links: