Download Print this page

Advertisement

Quick Links

Delta VF-MD drive short manual for encoder model
Drive I/p connections:
Drive o/p connections:
Control terminals: DCM-door common signal
Encoder terminals: VP-red wire, black-DCM, yellow-A, blue-B (put dip
switch in +12v mode) .this switch near to VP terminal.
Door feedback signals: Door close limit signal-RC1 (com), RB1 (NC), RA1
(no), Door open limit signal-RC2 (com), RA2 (no)
Drive program:
User parameters:
0-17-30 %( vary depend on site) , 0-18-1
Basic parameters:
1-00-50.0, 1-01-50.0, 1-02-220volts,1-07-6.0
Motor and feedback parameters:
2-02-0.2(put first), 2-01-0.58, 2-04-6, 2-11-50, 2-12-1, 2-13-450, 2-14-50, 2-
18-20
Motor auto tuning –put 0-12-0, then press run command for auto tuning.
After this check motor direction by press run command door should close
.if direction reverse interchange two motor wires and repeat motor tuning
again
Door open control parameters:
3-00 -6, 3-01-20, 3-02 -20, 3-03 -90, 3-04-6.0, 3-05-95, 3-06-4.0, 3-12-20,
3`-17-999.9
L1- PHASE, L2-NEUTRAL
U, V, W TO MOTOR
REV- door open signal
FWD-door close signal

Advertisement

loading

Summary of Contents for Delta VF-MD

  • Page 1 Delta VF-MD drive short manual for encoder model Drive I/p connections: L1- PHASE, L2-NEUTRAL Drive o/p connections: U, V, W TO MOTOR Control terminals: DCM-door common signal REV- door open signal FWD-door close signal Encoder terminals: VP-red wire, black-DCM, yellow-A, blue-B (put dip switch in +12v mode) .this switch near to VP terminal.
  • Page 2 Door close control parameters: 4-00 -18.0, 4-01-15.0, 4-02 -6.0, 4-03 -5.0, 4-04-4.0, 4-15-20, 4-22-999.9 Digital output parameters: 6-00-21, 6-01-22 Door width tuning process: 1.put door in half position ,after this enter parameter 0-12-0, 2-23-1 then give run command ( in this time the door open and close completely ) if tuning complete successfully ok .go to step3.