Electrical System
• Always stop engine and remove ignition key when servicing electrical system.
• Shock hazard. Do not handle electrical components with wet hands.
Battery
• Never charge battery when the fluid level is below "lower level" line. Charging
battery with insufficient fluid may shorten battery life or cause an explosion.
• Battery fluid (diluted sulfic acid) is corrosive and causes severe burns. Be
extremeley cautious when handling battery fluid. If battery fluid is spilt on
clothes, immediately rinse with plenty of water. If spilt on skin or in an eye,
immediately rinse with plenty of water and promptly consult a physician.
• Explosion hazard. Keep open flame or spark away from battery. Hydrogen
gas generated during charging is extremely explosive.• Never fill battery fluid
beyond "upper level" line. Battery fluid may spill and cause damage to machine
or injury to person.
• Always disconnect (-) terminal first, and connect (+) terminal first. Disconnecting
or connecting in the opposite order may cause a short circuit.
• When installing battery, make certain to connect (+) and (-) terminals to their
original positions. Avoid contact between terminals and other surrounding
parts.
• Use wet cloth to clean battery. Dry cloth may generate static electricity, which
may cause explosion.
• Do not touch terminals. Electric shock may occur.
Maintenance
-71-
5
Need help?
Do you have a question about the CMX 227 and is the answer not in the manual?
Questions and answers
Where is the battery located on a canycom cmx227 lawnmower
The battery on a CanyCom CMX 227 lawnmower is located behind the front cover, tray, and headlight unit.
This answer is automatically generated