DM Data Transfer
5-5-2

Settings Details

Name
DM Write Request Bit (Coordinator
Module to Motion Control Module)
DM Read Request Bit (Motion
Control Module to Coordinator
Module)
Slot No. of Motion Control Module
for DM Transfer
DM Transfer Size (number of
words)
First DM Transfer Source Word
First DM Transfer Destination
Word
Transfer Error Flag
Transfer Busy Flag
5-5-3

Executing DM Data Transfer

Step 1: Make Auxiliary
Area Settings
The settings for using the DM data transfer function are made in the Auxiliary
Area.
Address
A530.00
DM data transfer is executed from the Coordinator Mod-
ule to Motion Control Module when this bit turns ON.
A530.01
DM data transfer is executed from the Motion Control
Module to Coordinator Module when this bit turns ON.
A531
Specifies the slot number (in 4-digit hexadecimal) for the
Motion Control Module with which DM data is to be
transferred.
0001: Motion Control Module #1
0002: Motion Control Module #2
0003: Motion Control Module #3
0004: Motion Control Module #4
A532
Specifies the size, in number of words, of the DM data to
be transferred.
0001 to 01F3 hex (1 to 499 words)
A533
Specifies the first address of the DM transfer source in
the Coordinator Module or Motion Control Module.
0000 to 7FFF hex
A534
Specifies the first address of the DM transfer destination
in the Coordinator Module or Motion Control Module.
0000 to 7FFF hex
A535.14
Turns ON when a DM data transfer error occurs.
A535.15
Turns ON during DM data transfer and turns OFF when
the transfer has been completed.
DM Read/Write
Request Bit
A535.15
Transfer Busy Flag
A535.14
Transfer Error Flag
Error cleared at start of transfer.
To transfer data, the Auxiliary Area settings, described earlier, must be made.
The following settings are made in the Auxiliary Area.
• Slot No. of Motion Control Module for DM Transfer
Specifies the slot number for the Motion Control Module to which DM data
is being transferred.
• Transfer details
• DM Transfer Size (number of words)
• First DM Transfer Source Word
• First DM Transfer Destination Word
Description
Turns ON when transfer
has been completed if an
error has occurred.
Section 5-5
Read/write
Enabled