Analog Outputs
Specified Output Values and Analog Output Signals
−10 to 10 V
Analog output signal
+11.0 V
+10.0 V
0.0 V
−10.0 V
−11.0 V
0000
EC78
Resolution: 10,000
EA84
0 to 5 V
Analog output signal
5.25 V
5.0 V
0.0 V
−0.25 V
0000
FF38
Resolution: 4,000
7-10-4 Applicable Instructions
END Refreshing
With Immediate
Refreshing
228
Specified output value
(4-digit Hex)
1388
157C
Specified output value
0FA0
(4-digit Hex)
1068
Set the analog output values in A560 and A561 using an instruction such as
the MOV instruction.
Outputs can be controlled with SPED(885) and ACC(888) as outlined below.
SPED(885) can be used to change the output value in steps.
(@) SPED
P: Port specifier
P
(#0001 for analog output 1 or #0002 for analog output 2)
#0000
M: Always #0000
F
F: Analog output value
0 to 10 V
Analog output signal
10.5 V
10.0 V
0.0 V
−0.5 V
0000
Resolution: 4,000
FF38
1 to 5 V
Analog output signal
5.2 V
5.0 V
1.0 V
0.8 V
0000
FF38
Resolution: 4,000
Section 7-10
Specified output value
(4-digit Hex)
0FA0
1068
Specified output value
0FA0
(4-digit Hex)
1068
Need help?