Wiring Methods - Omron HOME SECURITY SYSTEM - MOTION SENSOR FQM1-CM001 Operation Manual

Fqm1 series flexible motion controller
Table of Contents

Advertisement

Wiring Module Connectors
Connecting Analog
Outputs (FQM1-
MMA21)
Connecting Analog Inputs (FQM1-MMA21)
Voltage Input
Current Input
3-3-4

Wiring Methods

Connectors
Connecting MIL Connectors
74
Output signals are connected as shown in the following diagram.
FQM1-MMA21
40-pin connector
Pin No.
38 (V2+)
40 (V2−)
37 (V1+)
39 (V1−)
FQM1
Special I/O connector
Pin No.
33 (V1+)
35 (V1−)
FQM1
Special I/O connector
Pin No.
34 Current input
33 (V1+)
35 (V1−)
Either make a cable using the special connector (purchased separately), or
connect to a terminal block using an OMRON special cable with a connector.
Note
(1) Do not apply voltages that exceed the maximum switching capacity of
output circuits and the input voltage of I/O circuits.
(2) Do not mistake positive and negative when wiring power supply, where
there are positive and negative terminals.
(3) To conform to the EC Low Voltage Directive, use a DC power supply for
I/O that has reinforced or double insulation.
(4) Check that the connector wiring has been performed correctly before
supplying power.
(5) Do not pull on cables. Doing so may result in disconnection.
(6) Do not bend cables beyond their natural limit. Doing so may result in dis-
connection.
Connector type
Pressure welded
+
Analog output 2
+
Analog output 1
Shield
+
Analog input
Shield
+
Analog input
Shield
Number of
Ordering as a set
pins
(OMRON)
26 pins
XG4M-2630-T
40 pins
XG4M-4030-T
Section 3-3
DDK Ltd.
FRC5-A026-3T0S
FRC5-A040-3T0S