System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations
Address
Bits
A500
14
Error Log Pointer Reset
and Memory Not Held
Flag OFF Bit
A400
00 to 15 Error code
FAL/FALS Errors
Address
Bits
A401
06
FALS Error Flag
(fatal error)
A402
15
FAL Error Flag
(non-fatal error)
Memory Errors
Address
Bits
A401
15
Memory Error Flag (fatal
error)
A403
00
UM Error Flag
04
System Setup Error
Flag
10
Flash Memory Error
Flag
13
Analog Offset/Gain
Error Flag
14
Flash Memory DM
Checksum Error Flag
A404
14
Memory Not Held Flag
System Setup
Address
Bits
A402
10
System Setup Error
Flag
A409
00 to 15 System Setup Error
Location
I/O Errors
Address
Bits
A401
10
I/O Setting Error Flag
Module Errors
Address
Bits
A402
05
Motion Control Module
Monitoring Error Flag
(Coordinator Module
only)
13
Coordinator Module
WDT Error Flag (Motion
Control Modules only)
14
Coordinator Module
Fatal Error Flag (Motion
Control Modules only)
Name
The error log pointer in A408 is reset to 0000 hex and Memory Not
Held Flag (A404.14) is turned OFF when this bit is turned ON.
When a non-fatal error (user-defined FAL(006) or system error) or a
fatal error (user-defined FALS(007) or system error) occurs, the hexa-
decimal error code is written to this word.
Name
Turns ON when a non-fatal error is generated by the FALS(006)
instruction. The FQM1 will stop operating.
Turns ON when a non-fatal error is generated by executing FAL(006).
The FQM1 will continue operating.
Name
Turns ON when there is an error in the memory. FQM1 operation will
stop and the ERR indicators on the front of the Modules will light.
Turns ON when there is an error in the user memory.
Turns ON when there is an error in the System Setup in the Coordina-
tor Module or Motion Control Module.
Turns ON when the flash memory is physically destroyed.
Turns ON when there is an error in the analog I/O offset/gain adjust-
ment value in flash memory.
Turns ON when there is an error in the DM Area data backed up in
flash memory in the Coordinator Module.
Turns ON when corruption is found in the check performed after turn-
ing ON power in the areas backed up during power interruptions (DM
Area (Coordinator Module only) and Error Log Area).
Name
Turns ON when there is a setting error in the System Setup.
When there is a setting error in the System Setup, the location of that
error is written to A409 in 4-digit hexadecimal.
Name
Turns ON when more than four Motion Control Modules are connected
to the Coordinator Module.
Name
Turns ON in the Coordinator Module when a system error, such as a
WDT error, occurs in any of the Motion Control Modules.
Turns ON in the Motion Control Modules when a WDT error occurs in
the Coordinator Module.
Turns ON in the Motion Control Modules when a fatal error occurs in
the Coordinator Module.
Function
Function
Function
Function
Function
Function
Appendix C
Controlled by
User
Module
Controlled by
Module
Controlled by
Module
Controlled by
Module
Controlled by
Module
Controlled by
Module
345

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fqm1-mma21Fqm1-mmp21

Table of Contents