Checking The Radiator; Installing The Radiator - Yamaha Wolverine YX70EPNG Service Manual

Hide thumbs Also See for Wolverine YX70EPNG:
Table of Contents

Advertisement

EBS30213

CHECKING THE RADIATOR

1. Check:
• Radiator fins
Obstruction → Clean.
Apply compressed air to the rear of the radia-
tor.
Damage → Repair or replace.
TIP
Straighten any flattened fins with a thin, flat-head
screwdriver.
2. Check:
• Radiator hoses
• Radiator pipes
Cracks/damage/wear → Replace.
3. Measure:
• Radiator cap opening pressure
Below the specified pressure → Replace the
radiator cap.
Radiator cap opening pressure
107.9–137.3 kPa (1.1–1.4
kgf/cm², 15.6–19.9 psi)
▼▼▼
▼ ▼▼▼
▼ ▼▼▼
a. Install the radiator cap tester "1" and radiator
cap tester adapter "2" to the radiator cap "3".
Radiator cap tester
90890-01325
Mityvac cooling system tester kit
YU-24460-A
Radiator cap tester adapter
90890-01352
Pressure tester adapter
YU-33984
▼ ▼▼▼
▼ ▼▼▼
▼ ▼▼▼
b. Apply the specified pressure for ten seconds
and make sure there is no drop in pressure.
▲▲▲
▲ ▲▲▲
4. Check:
• Radiator fan
Damage → Replace.
Malfunction → Check and repair.
Refer to "COOLING SYSTEM" on page 9-29.
EBS30214

INSTALLING THE RADIATOR

1. Install:
• Radiator outlet pipe "1"
• Radiator inlet pipe "2"
TIP
Align the punch marks "a" on the radiator inlet
pipe and outlet pipe with the hose clamp.
▼▼▼
2. Fill:
• Cooling system
(with the specified amount of the recom-
mended coolant)
6-6
RADIATOR
▲ ▲▲▲
▲ ▲▲▲
▲ ▲▲▲
2
a
▲ ▲▲▲
▲▲▲
a
1

Advertisement