5.2
SW Update via the Service Terminal
Procedure
Date printed: 24.10.03
The following terminal settings must be used:
1.
Dump all snapshots, mic settings, and configuration data to a PC-Card or
to the service terminal.
2.
Connect the cable between the PC (COM1 or COM2) and the OnAir 1000
("service terminal" connector on the controller board). To do this, you
have to open the console,
3.
After pressing ENTER or switching the console on, you will see the mes-
sage
ServIf:\
on the terminal.
If you enter ? followed by ENTER, you will see a list of all possible debug
commands.
4.
To download the new software you need to type
startdownload serviceterminal, followed by ENTER at the
prompt.
5.
Then send the file OA1000.ABS as a text file.
This procedure will take about 10...15 min to complete the download.
6.
Reload all snapshots, mic settings, and configuration data from the PC-
Card or the service terminal.
SW V4.0
OnAir 1000 Digital Mixing Console
refer to chapter
4.1.
Service Terminal 5-3