Studer SW V4.0 OnAir 1000 Operating And Service Instructions page 193

Digital broadcast mixing console
Table of Contents

Advertisement

For Consoles with Serial No. 1281 and below:
Date printed: 27.10.03
Repeat this procedure for each of the four output connectors of each of the
three Analog Output Units.
Notes:
Please consider that maximum undistorted level of the analog outputs is
+23 dBu (@ 0 dB
not exceed a value of +14 dBu (with an input signal of –9 dB
ering the standard headroom margin of 9 dB.
Once finished, don't forget to re-establish the console settings as they
were before the alignment procedure.
Select the Channel Control page (e.g. "I 9A"): Touch HOME and press the
SEL key of the corresponding channel. Perform the following settings on
the Channel Control page:
MODE: ST (stereo), LR (normal stereo mode)
PHASE: NORM
CAL: 0 dB
Routing: to the PGM and REC outputs; the ΣPROGRAM and ΣRECORD
touch-screen fields must be highlighted.
BAL: center position.
Switch the equalizer off by pressing the EQ key if it is illuminated.
Switch the console off.
Open the console according to
nected so that the console remains operative.
Remove the Analog Output Unit to be aligned (refer to
re-connect it to connector P71 of the DSP board using the 64pin extension
cable 1.942.500.26. Reconnect the daisy-chain flat cable of the Output
Module Bus to the extension cable. Now the Analog Output Unit can be
placed in front of the console on an insulating sheet, e.g. a piece of card-
board. Put down the console front cover, but don't fix it with its screws.
Set the jumpers of the Analog Output Unit temporarily to RECORD (for
the lower/"B" output connectors) and to PGM (for the upper/"A" output
connectors), select STEREO for both outputs A and B; refer to the illus-
tration on the following page.
Switch the console on again.
Switch the corresponding channel ON, and set its channel fader as well as
the PGM and REC faders to their 0 dB position.
Connect an analog audio level meter to one of the PCB's output connec-
tors.
Align for a reading of your desired nominal level (default factory setting:
+6 dBu) on the audio level meter; select the corresponding trimmer poten-
tiometer according to the table below.
PGM/A, right
Repeat this procedure for each of the four output connectors of each of the
three Analog Output Units.
Note:
Please consider that maximum undistorted level of the analog outputs is
+23 dBu (@ 0 dB
not exceed a value of +14 dBu (with an input signal of –9 dB
ering the standard headroom margin of 9 dB.
SW V4.0
OnAir 1000 Digital Mixing Console
) into a 300 Ω load. When setting the output levels, do
FS
chapter
Output:
PGM/A, left
REC/B, right
REC/B, left
) into a 300 Ω load. When setting the output levels, do
FS
4.1, but leave the front cover con-
chapter
Align with:
RA1
RA2
RA3
RA4
Service 4-7
), consid-
FS
4.2.1) and
), consid-
FS

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw4.03 onair 1000

Table of Contents