7.7

High voltage power supply PCB ASSY

(1) Disconnect the high voltage PCB flat cable from the main PCB ASSY.
Note:
• After disconnecting the flat cable, check that the cable is not damaged at the end
or short-circuited. When connecting the flat cable, do not insert it at an angle. After
insertion, check that the cable is not at an angle.
(2) Remove the two taptite bind B M4x12 screws.
(3) Remove the two hooks to remove the high voltage power supply PCB ASSY from the
machine.
High voltage power
supply PCB ASSY
Taptite bind B M4x12
Assembling Note:
• When removing the high voltage power supply PCB ASSY, electrode or electrode
springs will come off. When assembling the high voltage power supply PCB ASSY,
make sure that the electrode and electrode springs are assembled.
• Attach it by engaging the slits of the electrode with the ribs of the machine.
• Make sure that the spring is inserted fully into the end of the electrode.
• When assembling the high voltage power supply PCB ASSY, make sure that the toner
cartridge and the drum unit have been removed. They could twist the electrode.
Electrode springs
High voltage
PCB flat cable
Fig. 2-24
Electrode
Spring
Fig. 2-25
2-28
Main PCB ASSY
Hooks
Ribs
Slit
Electrode
Slit
Confidential