【Enter Setup】

Image Stabilization Timeout

The scanner waits for the image stabilization timeout to occur before activating a decode session every
time it detects a change in ambient illumination. The image stabilization timeout is programmable in 1ms
increments from 0ms to 1,600ms. The default setting is 500ms.
Set the Image Stabilization Timeout to 1,500ms:
1. Scan the Enter Setup barcode.
2. Scan the Image Stabilization Timeout barcode.
3.
4. Scan the Save barcode. (See the "Save/Cancel Barcodes" section in Appendix)
5. Scan the Exit Setup barcode.

Continue after Good Read

Continue after Good Read: The scanner starts next decode session after good read.
Pause after Good Read: The scanner starts another round of illumination monitoring and image
stabilization after good read.
**【Pause after Good Read】
**【Exit Setup】
【Image Stabilization Timeout】
Scan the numeric barcodes "1", "5", "0" and "0". (See the "Digit Barcodes"
section in Appendix)
【Continue after Good Read】