Circuit Card Reference; Nn43001-311 01.04 Standard - Nortel Circuit Card 311 Reference

Circuit card
Table of Contents

Advertisement

LD 97 - Defining Loss Switching mode.
Prompt
Response
REQ:
CHG
TYPE:
SYSP
...
NATP
YES
2. Define Loss Switching Class Of Service. Respond to the prompts in
LD 14 - Defining Loss Switching Class Of Service.
Prompt
Response
REQ:
CHG
TYPE:
COT
XTRK
XCOT
SIGL
LOP
...
CLS
LOL
Equivalencies
The following equivalencies do apply:
The entries TRC and NTC are no longer allowed for the Generic XFCOT.
Trunk to Trunk connection
When any disconnect supervision is configured (CLS = BAT, BTS), the
Loop Start Trunk of the Generic XFCOT is marked as having disconnect
supervision and therefore follows the same rules as a Ground Start Trunk.
There is no configuration involved for this operation.
Copyright © 2003-2008, Nortel Networks
.
Description
IPE system parameters configuration
Select North American transmission plan.
Note: The default to the NATP prompt is NO, and therefore this
prompt must always be checked during installation.
LD 14 as shown.
Description
LOL= Long Line
Note: The XFCOT uses the CLS Long Line (LOL) and Short
Line (SHL) for Loss Switching purposes and that the card and
trunk type is different from the XUT.
XFCOT COT SHL is equivalent with XUT COT TRC
XFCOT COT LOL is equivalent with XUT COT NTC.
Nortel Communication Server 1000

Circuit Card Reference

NN43001-311 01.04 Standard

Release 5.0 23 May 2008
Applications 1015

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000 con?guration guide

Table of Contents