CONVERSION FROM NG TO LP

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION!!
Each Kit contains one LPG
Conversion Kit
LPG Conversion Kit Contains:
Qty. Part #
Description
1
904-575
Burner Orifice #55
1
918-590
Decal "Converted to
LPG"
1
908-528
Red "LPG" label
1
904-529
5/32" Allen Key
1
910-101
LPG Injector
(Pilot Orifice)
1
911-011
Stepper motor
1
919-467
Instruction Sheet
Installation of the LPG
Conversion Kit:
1) Shut off the gas and electrical supply.
2) Remove faceplate (if installed).
3)
Remove the safety screen and glass
door.
a) Release the two hooks from the
bottom of the glass door.
b) Swing the door out 45 degrees from
the bottom - then lift up and out.
c) Remove the logs, embers, and brick
panels (if installed).
4)
Remove the 2 screws holding the Burner
Assembly to the firebox base. Push the
Burner Assembly to the left and lift out.
34 |
Remove the 2 screws, push Burner
Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace
Assembly to the left and lift out.
Conversion from NG to LPG
For P33E-10 Using SIT 885 NOVA Gas Valve
P33E-10 using SIT 885 NOVA Gas Valve
5) R emove pilot retainer clip with pliers and
pull off the pilot cap to expose pilot orifice.
Pilot Cap
6)
Unscrew the pilot orifice with the Allen
key and replace with the LPG pilot orifice
in the kit and replace pilot cap.
7)
Remove burner orifice with a 1/2"
wrench and discard. Use another
wrench to hold on to the elbow behind
the orifice.
8)
Reinstall new burner orifice LPG
Clip
stamped #55 and tighten.
9) Remove regulator and discard. Install
the Hi/Lo pressure regulator onto the
valve with 2 screws as shown below.
10) Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
11) Replace yellow "NG" label with red
"LPG" label.
12) Reverse steps 4 through 1
13) Check for gas leaks.
14) Check inlet and outlet pressures.
15) Check operation of flame control.
These instructions must be
Burner Orifice
Installer Notice:
left with the appliance.