Direct Vent Gas Fireplace
MODELS:
P33-NG10 Natural Gas
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
919-392
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
P33-10 Zero Clearance
P33-LP10 Propane
6988 Venture St., Delta, BC Canada, V4G 1H4
Owners &
Installation Manual
www.regency-fire.com
12.16.14

Advertisement

Table of Contents
loading

Summary of Contents for Regency P33-LP10

  • Page 1 Direct Vent Gas Fireplace Installation Manual www.regency-fire.com MODELS: P33-NG10 Natural Gas P33-LP10 Propane WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 The P33-10 has been approved by Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.
  • Page 3 INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey/Intertek as a Direct Vent Wall Furnace to the following standards: ® VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2014 • CSA 2.33-2014 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN/CGA-2.17-M91.
  • Page 4: Table Of Contents

    Venting Introduction ........... 14 First Fire ..............41 Exterior Vent Termination Locations ......15 Aeration Adjustment ..........42 Normal Operating Sounds of Gas Appliances ... 42 Regency Direct Vent flex System ......16 ® Installation Procedures ..........17 Maintenance Instructions........... 42 Rigid Pipe Venting Systems ........
  • Page 5: Safety Label

    Delta, BC, Canada Standard in Canada. VENTILATION : Système de GS de Dura-conduit de Simpson énuméré par utilisation ou circuit de mise à l'air libre direct de Regency. Made in Canada/ Seulement pour la décharge directe sans connexion de conduit. Cet appareil \ndoit être installé selon les instructions d'installation du fabricant Fabrique au Canada et avec des codes locaux éventuels ;...
  • Page 6: For The State Of Massachusetts Only

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 7: Unit Dimensions With Vignette Faceplate

    UNIT DIMENSIONS WITH VIGNETTE FACEPLATE 33" (838mm) 23" (584mm) 2” 12-3/4" 35" (324mm) (889mm) Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 8: Important Message

    National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 9: Installation Checklist

    15-20 min. to stabilize. CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the Diagram 1 manufacturer. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 10: Clearances With Vignette Faceplate

    Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. Combustible mantel leg clearances as per diagrams below: 10 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 11: Mantel Leg Clearances With Flush Glass

    MANTEL LEG CLEARANCES WITH FLUSH GLASS Combustible mantel leg clearances from side of unit as per diagram: Maximum 1-1/2" projection at 2" minimum clearance. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 12: Wall Mount On / Off Switch Installation

    11. Using the two (2) screws provided secure the cover plate to the Receiver. Low Voltage Junction Box Profl ame Receiver J-Box Receiver Slider Switch Wall Plate 10 ft. wire harness with 12 pin connector Diagram 1 12 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 13: Framing And Finishing

    You must maintain clearance from faceplate option. the vent to combustible materials See framing section when using faceplate in for flex or for Rigid Vent (Refer to this manual. "Clearances" Section). Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 14: Unit Assembly Prior To Installation

    There are 5 vent systems approved for use with the P33-10: the Regency Direct Vent Flex System for Horizontal Terminations only and the Simpson ®...
  • Page 15: Exterior Vent Termination Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 16: Regency ® Direct Vent Flex System

    (Part# 946-523/P) Notes: spring 1) Liner sections should be continuous spacer without any joints or seams. 2) Only Flex pipe purchased from Regency ® 6-7/8" may be used for Flex installations. See Figure 1 below for (173mm) Alternate Caps.
  • Page 17: Installation Procedures

    INSTALLATION PROCEDURES for Regency Direct Vent System (Flex) ® *If this is an outside corner, the minimum distance between the vent and the outside 1) Locate the unit in the framing, rough in the corner is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Dura-Vent...
  • Page 18: Rigid Pipe Venting Systems

    , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace ® Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. 18 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 19: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    4DFSP 4DFS SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 20 Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
  • Page 21: Rigid Pipe Venting Arrangements

    Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994). Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 22 Propane and Natural Gas. Maximum two 45 elbows allowed. • Vent must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. 22 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 23: Horizontal Terminations

    Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems. (Refer "Rigid Pipe Venting Systems" Section) A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. Note: Regency Direct Vent System (Flex) ® is only approved for horizontal terminations.
  • Page 24 3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 5' Max. 8' Min. 8' Max. elbows is required. 24 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 25 1 foot between 90 6' Max. 6' Min. elbows is required. 5' Min. 8' Max. 6' Min. For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 26 5' Min. 6' Max. 8' Min. Please note min. 1 foot 6' Min. 7' Max. 9' Min. between 90 elbows is required. 7' Min. 8' Max. 10' Min. 26 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 27: Vertical Termination With Co-Linear Flex System In A Masonry Chimney

    3" Co-linear Adapter with flashing Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Rigid Pipe Adapter Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 28: Venting Arrangements - Vertical Terminations

    VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. 28 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 29: Unit Installation With Horizontal Termination

    Failure to do so may Thimble (Part # 620-926) over the vent result in drafting or performance issues not pipe. covered under warranty. Silicone (red RTV) is optional. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 30: Unit Installation With Vertical Termination

    Do not use open flame for leak slide storm collar over the pipe section and testing. Diagram 2 seal with a mastic. 30 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 31: Pilot Adjustment

    (High) 3.5"+/- 0.2" w.c. Note: To properly check gas pressure, both inlet and manifold pressures P33-LP10 System Data should be checked using the valve pressure ports on the valve. With Flush Glass: 1) Make sure the valve is in the "OFF"...
  • Page 32: Conversion From Ng To Lp

    Assembly to the left and lift out. label. 15. Check operation of flame control. 16. Check for proper flame appearance and glow on logs. Burner Orifice Reinstall new burner orifice LPG stamped #55 and tighten. Installer Notice: These instructions must be left with the appliance. 32 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 10.17.14 919-466...
  • Page 33: Optional Brick Panels

    5) Slide the Top Brick Panel into position and slide the Top Brick Retaining clips so that they hold the Top Brick Panel in place and tighten down the screws. 2nd Grate Tab Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 34: Standard Flush Door

    See Diagram 2. 5th Grate Tab 34 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 35: Optional Wall Thermostat

    Note: Preferable if the thermostat is installed on an interior wall. 18 GA. 20 Ft. 20 GA. 12 Ft. Regency offers an optional programmable ® 22 GA. 9 Ft. thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.
  • Page 36: Wiring Diagrams

    Caution: Ensure that the wires do Wiring errors can cause not touch any hot surfaces and are improper and dangerous away from sharp edges. operation. 36 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 37: Installing The Optional Fan

    THESE FANS COLLECT A LOT OF DUST FROM WITHIN YOUR HOME. ENSURE YOU MAINTAIN THESE FAN MOTORS ON A REGULAR BASIS BY VACUUMING THE FAN BLADES AND THE HOUSING WITH A SOFT BRUSH NOZZLE. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 919-474 10.29.14...
  • Page 38: Vignette Faceplate And Safety Screen Install

    Vignette frame (see below). Screen below. assembly is secured at bottom with magnets. Screen Assembly Vignette Frame Reverse Steps to remove. Secure Vignette frame using 2 screws in locations shown below. Final Install 38 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 39: Optional Finishing Trim

    Line up the screw holes on the finishing trim and Vignette Faceplate bracket with the unit–fasten with one screw on each side. Reinstall the glass door and safety screen. Finishing Trim Top Finishing Trim Side Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ® 10.29.14 919-475...
  • Page 40: Copy Of The Lighting Plate Instructions

    Mettre le bouton de commande de gaz en position OFF pour éteindre la veilleuse. Pour économiser le carburant, éteignez la veilleuse quand l’appareil reste longtemps inutilisé. DO NOT REMOVE THIS INSTRUCTION PLATE 919-456 40 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 41: Operating Instructions

    NEVER clean code below. Button the glass while it is hot. Proflame video Diagram 2 Remote shown in Manual Mode on Hi 6. The unit will turn on. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 42: Aeration Adjustment

    NOT covered under warranty. dull clicking sound may be audible, this is normal operation of a gas regulator or valve. Note: Aeration Adjustment should only be performed by an authorized Regency ® Unit Body/Firebox: Installer at the time of installation or Different types and thicknesses of steel will expand service.
  • Page 43: General Vent Maintenance

    If for any reason a log should need replacement, you must use the proper replacement log. The position Your Regency fireplace is supplied with high ® of these logs must be as shown in the diagrams temperature, 5 mm Neoceram ceramic glass that will under Log Installation.
  • Page 44: Removing Valve

    Hint: If you are using black pipe, ensure that there is a union by the valve, otherwise removal will be almost impossible. screws Rear Log Stand Diagram 2: Rear Log Stand 44 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 45: Main Assembly

    Gasket - Flue Collar 91) 946-002 Round to Oval Adaptor 31) * Flue Mounting Plate 92) 946-001 Oval Duct Adaptor 93) 946-007 Angle Bracket 94) 946-517/P Fan Assembly - HeatWave Option Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 46: Parts List

    HEAT WAVE DUCT KIT #946-556 BRICK PANEL SET FAN ASSEMBLY 46 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 47: Burner & Log Assembly

    Pilot Tube w/nuts 910-073 DC spark box 910-074 DC spark box wire 911-030 Fan Control Module 439-969 Conversion Kit LP 911-032 Valve/Remote Wiring Harness 433-020 Pilot Shield *Not available as a replacement part. Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 48: Vignette Faceplate And Safety Screen

    VIGNETTE FACEPLATE AND FINISHING TRIM Part # Description 439-922 Vignette Faceplate Platinum 439-923 Vignette Faceplate Black Chrome 439-924 Vignette Faceplate Black 439-926 Vignette Faceplate Tuscan Sunset 430-940 3 sided Finishing Trim 48 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 49 Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 50 50 | Regency P33-10 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 51: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-field service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthor- ized service persons or dealers.
  • Page 52 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency, Panorama, AstroCap are trademarks of FPI Fireplace Products International Ltd. © Copyright 2014, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

P33-ng10

Table of Contents