Rigid Pipe Venting Systems - Regency PANORAMA P33E Owners & Installation Manual

Hide thumbs Also See for PANORAMA P33E:
Table of Contents

Advertisement

installation
|
20

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations
The minimum components required for a basic
horizontal termination are:
AstroCap Horizontal Termination Cap
1
1
45
Elbow
o
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness
(see chart)
For siding other than vinyl furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal
must not be recessed into siding.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
Horizontal
Termination
The FPI AstroCap
and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent
TM
American Metal Products Ameri Vent Direct Vent, Security Secure Vent
Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
20 |
Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace
Alternate
Caps
VIGNETTE + VIGNETTE FINISHING TRIM
FLUSH FINISH
WARNING:
Do not combine venting components from
different venting systems.
However use of the AstroCap
is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent , Selkirk Direct-Temp,
Ameri Vent Direct venting and Security Secure
Vent systems. Use of these systems with the
Rigid Pipe adaptor is deemed acceptable and
does not affect the Warnok Hersey/Intertek
listing of components.
, Selkirk Direct-Temp. AstroCap
®
and FPI Riser
TM
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Direct Vent Pro,
®
is a proprietary trademark of FPI Fireplace
TM

Advertisement