OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait.

FIRST FIRE

The first fire in your fireplace is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fireplace for at least four (4) hours the
first time you use it with the fan on.
When first operated, the unit will release an odour
caused by the curing of the paint, the burning
off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at
this time. Open a few windows to ventilate the
room for a couple of hours.
The glass panel may require cleaning after the
unit has cooled down. DO NOT ATTEMPT TO
CLEAN THE GLASS WHILE IT IS HOT.
Note: When the glass is cold and the
appliance is lit, it may cause
condensation and fog the glass.
This condensation is normal and
will disappear in a few minutes as
the glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
During the first few fires, a white film
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the film will bake on and
become very difficult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
AERATION
ADJUSTMENT
The air shutter can be adjusted by moving
the adjusting wire up or down. The wire is
accessed through the bottom opening(remove
safety screen). Open the air shutter for a blue
flame or close for a yellower flame. The burner
aeration is factory set but may need adjusting
due to either the local gas supply or altitude.
Minimum Air Shutter Opening:
3/16" Natural Gas - Orifice # 44
3/8"
Propane -
Orifice # 55
CAUTION: Carbon will be produced if air
shutter is closed too much.
Closed - Tall yellow
Open - Short blue
Air
shutter
wire
Adjustment Wire: push to close
or pull to open aeration cap
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
Note: Aeration Adjustment should only
be performed by an authorized
Regency
Installer at the time of
®
installation or service.
NORMAL OPERATING
Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace

operating instructions

|
49
|