Regency Sunrise P33SE-NG4 Owners & Installation Manual

P33se gas fireplace
Table of Contents

Advertisement

Quick Links

Regency P33SE
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-850a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
MODEL: P
P
www.regency-fi re.com
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
33
SE-NG4 Natural Gas
33
SE-LP4 Propane
04/13/11

Advertisement

Table of Contents
loading

Summary of Contents for Regency Sunrise P33SE-NG4

  • Page 1 Owners & Regency P33SE Installation Manual Gas Fireplace MODEL: P SE-NG4 Natural Gas SE-LP4 Propane www.regency-fi re.com WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fi re or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life.
  • Page 2 Congratulations! ® You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The P33SE has been designed to provide you with all the warmth and charm of a fi re at the fl ick of a switch. The model P33SE has been approved by Warnock Hersey for both safety and effi...
  • Page 3: Manufactured Mobile Home Requirements

    This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used. (Kit # 434-972) Ensure that structural members are not cut or weakened during installation. Regency P33SE Gas Fireplace...
  • Page 4: Table Of Contents

    High Elevation .............29 886 S.I.T. Valve Description .........29 Gas Pipe Pressure Testing ..........29 Conversion from NG to LP ..........30 Wiring Diagrams ............36 Optional fan Wiring Diagram ........37 Installing the Optional Fan ...........38 Optional Wall Thermostat ...........39 Regency P33SE Gas Fireplace...
  • Page 5: Safety Label

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency P33SE Gas Fireplace...
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency P33SE Gas Fireplace...
  • Page 7: Dimensions

    DIMENSIONS UNIT DIMENSIONS Regency P33SE Gas Fireplace...
  • Page 8: Installation

    fi replace. 9) Wear gloves and safety glasses for protection while doing required maintenance. 10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination. Regency P33SE Gas Fireplace...
  • Page 9: Installation Checklist

    fi replaces. Flat on Wall Corner Recessed into Wall/Alcove 11) Final check. Corner Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer. Regency P33SE Gas Fireplace...
  • Page 10: Clearances

    (room and/or alcove) Vertical (Rigid) 1-1/4" D: Alcove Width 48" (1219mm) Sidewall to Sidewall (Minimum) E: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) *Note: All measurements are from the top/side of the unit, not optional front. Regency P33SE Gas Fireplace...
  • Page 11: Mantel Clearances

    Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. MANTEL LEG CLEARANCES Combustible mantel leg clearances from side of unit as per diagram: Regency P33SE Gas Fireplace...
  • Page 12: Framing & Finishing

    fl ame package, carbon, blue fl ames etc. These are not product related issues. Regency P33SE Gas Fireplace...
  • Page 13: Framing Dimensions

    36" (914mm) Rigid 32" (812mm) Flex Vent Centerline Height* 30" (762mm) Rigid 26" (660mm) Flex Gas Connection Height* 1 1/2" (38mm) Gas Connection Inset* 4" (102mm) Gas Connection Width* 3" (76mm) * Measured from base of unit. Regency P33SE Gas Fireplace...
  • Page 14: Unit Assembly Prior To Installation

    ® There are 5 vent systems approved for use with the P33SE: the Regency Direct Vent Flex System for Horizontal Terminations only and the Simpson Dura-Vent, Selkirk Direct-Temp, Amerivent Direct Vent and Security Secure Vent Systems for Horizontal and Vertical Terminations (see following "Venting"...
  • Page 15: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency P33SE Gas Fireplace...
  • Page 16: Regency

    (8) screws #8 x 1-1/2" drill point, stainless steel (4) Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency ® may be used for Flex installations. Alternate Horizontal Termination...
  • Page 17: Rigid Pipe Venting Systems

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency P33SE Gas Fireplace...
  • Page 18: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    46DVA-ES (N/A - FPI) Offset Support 4DT-OS SV4SU Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM TE-4DE90 Wall Thimble Support/Ceiling Support 46DVA-DC SV4PF TE-4DE90B Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF Trim Plate-Black 4DT-TP 4DFPB 4DCP SV4LA Regency P33SE Gas Fireplace...
  • Page 19 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency P33SE Gas Fireplace...
  • Page 20: Rigid Pipe Venting Arrangements

    Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles. • Vent must be supported at offsets. Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994). Regency P33SE Gas Fireplace...
  • Page 21: Vertical Termination With Co-Linear Flex System

    46DVA-VCH High Wind Cap 46DVAGK 3" Co-linear Adapter with fl ashing Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Rigid Pipe Adaptor Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 Regency P33SE Gas Fireplace...
  • Page 22: Venting Arrangements - Vertical Terminations

    VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Horizontal Distance (Feet) Horizontal Distance (Feet) Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. Regency P33SE Gas Fireplace...
  • Page 23: Horizontal Terminations

    Maintain clearances to combustibles. 8"(0.2m) • Horizontal vent must be supported every 3 feet. • Firestops are required at each fl oor level and whenever passing through a wall. 2’ (0.6m) Minimum Minimum Simpson Dura-Vent Center-Line Flex Kit Center-Line Regency P33SE Gas Fireplace...
  • Page 24 5' Max. vertical and maximum 8 feet total horizontal. 3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. Regency P33SE Gas Fireplace...
  • Page 25 5' Min. 1 foot between 90 required. elbows is required. 5' Min. 8' Max. 6' Min. 6' Max. 6' Min. For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. Regency P33SE Gas Fireplace...
  • Page 26 8 feet total 4' Min. 5' Max. 7' Min. horizontal. 5' Min. 6' Max. 8' Min. Please note min. 1 foot 6' Min. 7' Max. 9' Min. between 90 elbows is required. 7' Min. 8' Max. 10' Min. Regency P33SE Gas Fireplace...
  • Page 27: Unit Installation With Horizontal Termination

    Wall ner pipe connection. Failure to do so may Thimble (Part # 620-926) over the vent result in drafting or performance issues not pipe. covered under warranty. Silicone (red RTV) is optional. Regency P33SE Gas Fireplace...
  • Page 28: Unit Installation With Vertical Termination

    Do not use open fl ame for leak testing. 7) Ensure vent is vertical and secure the base of the fl ashing to the roof with roofi ng rails, slide storm collar over the pipe section and Diagram 2 seal with a mastic. Regency P33SE Gas Fireplace...
  • Page 29: Pilot Adjustment

    Note: Screw should be snug, but do not over tighten. 886 S.I.T. VALVE DESCRIPTION 1) Manual high/low adjustment 2) Pilot adjustment 3) Outlet Pressure Tap 4) Inlet Pressure Tap 5) Pilot Outlet 6) Main Gas Outlet 7) Main Gas Inlet Regency P33SE Gas Fireplace...
  • Page 30: Conversion From Ng To Lp

    LPG pilot orifi ce 14) Check inlet and outlet pressures. in the kit and replace pilot cap. 15) Check operation of fl ame control. Installer Notice: These instructions must be left with the appliance. Regency P33SE Gas Fireplace...
  • Page 31: Gt Remote Installation

    (white) 12) Reverse steps 5 and 4. (green) 13) Match the remote control to the receiver - see remote control instructions. 14) Reverse steps 2 and 1. 15) Check to ensure there are no gas leaks. Regency P33SE Gas Fireplace...
  • Page 32: Gtm Remote Installation

    4) Remove DFC (digital fi rebox control box) from the fl oor of the unit. 9) Remove the hi/lo knob if installed by removing 2 screws as shown below. 5) Disconnect wire harness, ground wire and spark wire from DFC. Regency P33SE Gas Fireplace...
  • Page 33 19) Reverse steps 2 and 1. 20) Check to ensure there are no gas leaks. 14) To unattach these wires - un-clip from the wires on the stepper motor side as shown below. Press down this tab Regency P33SE Gas Fireplace...
  • Page 34: Gtmf Remote Installation

    9) Remove the hi/lo knob by removing 2 screws as shown below. 6) Disconnect wire harness, ground wire and spark wire from DFC. 10) Install the stepper motor in the same location the hi/lo knob was removed from - with 2 screws as shown below. Regency P33SE Gas Fireplace...
  • Page 35 18) Plug fan control module into recepticle located on the left hand side of the unit. 19) Match the remote control to the receiver - see remote control instructions. 20) Reverse steps 2 and 1. 21) Check to ensure there are no gas leaks.. Regency P33SE Gas Fireplace...
  • Page 36: Wiring Diagrams

    If the optional remote control is used, the AA batteries normally installed into the battery holder must be removed. The AA batteries in the receiver now operate the unit. Having AA batteries in both the battery holder and receiver will damage the gas valve. Proflame System Configuration 886 GTMF Wire Diagram SureFire™ Switch Regency P33SE Gas Fireplace...
  • Page 37: Optional Fan Wiring Diagram

    (for mobile home) Neutral Green Live Ground 120V AC 60 Hz Black Fan Thermodisc Rotary Speed (normally open) Control ground wire NOTE: Wiring schematics for P36E-4 (120 Volts), plug-in fan circuit with speed control switch on wall. Regency P33SE Gas Fireplace...
  • Page 38: Installing The Optional Fan

    fi rebox. 8) Secure the control plate assembly with 1 Check that no wire will touch the hot surfaces. screw as shown in Diagram 6. Diagram 2. Diagram 6 Diagram 2 Regency P33SE Gas Fireplace...
  • Page 39: Optional Wall Thermostat

    1) 4 AA batteries must be installed in the battery pack to operate the burner switch. 2) Install 2 AA batteries per side and connect as shown below - the battery pack is located on the lower left side of the unit. Regency P33SE Gas Fireplace...
  • Page 40: Optional Stainless Steel Refl Ective Panel Installation

    4) With the top panel in place - install back panel. The back panel fi ts under the top panel, push the top panel up to fi t back panel into position. (Diagrams 3) Diagram 3 Back Panel Regency P33SE Gas Fireplace...
  • Page 41: Glass Crystal Installation On Burner

    Blue Glass Crystals or optional Ceramic Spa Stones. NOTE: Only the supplied and approved pebbles are to be used. Use of any other type of pebbles or material can create a danger and will void warranty. Regency P33SE Gas Fireplace...
  • Page 42: Glass Door Installation

    Repeat for 2nd spring. See diagram 3. To remove the fl ush door, reverse the above steps. Diagram 3 To remove the fl ush door, reverse the above steps. Regency P33SE Gas Fireplace...
  • Page 43: Faceplate Installation

    5) The top of the faceplate has a fl ange that hooks over the top of the Heat Defl ector Top of Firebox Diagram 2 fl ush door. Heat Defl ector Diagram 6 Flange Faceplate Support Control Shield Mounting Frame Diagram 3 Regency P33SE Gas Fireplace...
  • Page 44 6) Hook the fl ange on the faceplate over the top of the fl ush door and gently lower the faceplate into place until it rests against the faceplate supports as shown in Diagrams 7 & 8. Diagram 7 Faceplate Diagram 8 Faceplate Support Diagram 9 Regency P33SE Gas Fireplace...
  • Page 45: Operating Instructions

    fi lm will bake on and become very diffi cult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. Regency P33SE Gas Fireplace...
  • Page 46: Copy Of Lighting Plate Instructions

    If service is to be performed - you must disconnect power to the unit, from the battery pack, refer to manual. Appuyez sur le bouton ON / OFF Si le service est effectuée, vous devez débrancher l'appareil, du bloc-piles, voir le manuel d'instruction pour plus de détails. DO NOT REMOVE THIS INSTRUCTION PLATE 918-628b Regency P33SE Gas Fireplace...
  • Page 47: Maintenance Instructions

    Replacement of the glass panels 8) Verify operation after servicing. should be done by a licensed or qualifi ed service person. Regency P33SE Gas Fireplace...
  • Page 48: Valve Tray Replacement

    Installing Valve 1) Install new Valve Tray Assembly. 2) Reverse steps 9-1. Diagram 3 7) Disconnect the inlet gas line. 8) Disconnect the EV1, EV2, and ground wires from the valve - as shown below. Ground Regency P33SE Gas Fireplace...
  • Page 49: Parts List

    Valve SIT - NG 911-005 Valve SIT - LP Not available as a replacement part. 911-006 Valve Pilot Assembly - NG 911-007 Valve Pilot Assembly - LP 904-434 Orifi ce #47 NG 904-241 Orifi ce #56 LP Regency P33SE Gas Fireplace...
  • Page 50 PARTS LIST MAIN ASSEMBLY FAN SWITCH ASSEMBLY Regency P33SE Gas Fireplace...
  • Page 51: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. ® The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 52 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency Sunrise and SureFire are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2010, FPI Fireplace Products International Ltd. All rights reserved.