Direct Vent Gas Fireplace
MODELS:
P33E-NG11 Natural Gas
Warning
FIre or explosion Hazard
failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
ertified to/Certifié pour : CSA 2.17-2017
C
919-963g
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
P33E Zero Clearance
®
P33E-LP11 Propane
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
ANSI Z21.88-2017
Homeowner: Please keep these instructions for future
CSA 2.33-2017
reference.
Owners &
Installation Manual
P33 Video
www.regency-fire.com
07.05.21

Advertisement

Table of Contents
loading

Summary of Contents for Regency Panorama P33E-NG11

  • Page 1 Panorama P33E Zero Clearance Owners & ® Installation Manual Direct Vent Gas Fireplace P33 Video www.regency-fire.com MODELS: P33E-NG11 Natural Gas P33E-LP11 Propane Warning FIre or explosion Hazard failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2 The P33E-11 has been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.
  • Page 3 INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency ® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2017 / CSA 2.33-2017 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CSA 2.17-2017.
  • Page 4: Table Of Contents

    Gas Appliance Maintenance ..........65 Venting Introduction ............. 23 Main Assembly ..............66 Exterior Vent Termination Locations ........24 Burner & Log Assembly ............68 Regency Direct Vent Flex System ........25 ® Vignette faceplate and finishing trim ......... 69 Installation Procedures ............26 Safety Screen and Louvers ..........
  • Page 5: Copy Of Safety Decal

    The safety label is located on the front inside base of the unit, visible when the bottom louver is open. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 6 (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipm ent, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 7: Unit Dimensions With Vignette

    Note: Gas connection is from the right hand side of the appliance & electrical connection on left hand side of the appliance. A metal receptacle box is supplied/installed with the appliance to make all 120 volt electrical connections. Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 8: Gas Installation Checklist

    This general checklist does not contain all pertinent installation details or specifics and does not supersede the guidelines in this manual. Your Regency dealer/installer should use it in conjunction with manual instructions. Please follow all local codes and jurisdictions in authority.
  • Page 9 REGENCY GAS INSTALLATION CHECKLIST Finishing If applicable, is only noncombustible material installed in the noncombustible areas? Do clearances meet installation and manual requirements? Do the mantels and/or projections comply with the installation manual? If applicable, was the solid fuel fireplace warning plate installed?
  • Page 10: Important Message

    SHOULD STAY AWAY TO AVOID BURNS or in the absence of local codes with the current OR CLOTHING IGNITION. National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. 10 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 11: Lighting Procedure

    2. Press and release the ON/OFF button on the remote handheld transmit- ter (see Diagram 2). An audible beep should be heard from the receiver. ON/OFF Button Diagram 2 Remote shown in Manual Mode on Hi Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 12: Copy Of Lighting Plate Instructions

    Utiliser l'interrupteur mural ou la télécommande pour mettre le système sur ''OFF''. Lors de l'entretien de l'appareil –débrancher l'alimentation électrique et couper le gaz de l'appareil. DO NOT REMOVE THIS INSTRUCTION PLATE 919-401a 12 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 13: Proflame I Remote Control Operating Instructions

    (*) The receiver may be independent or integral to the IFC hearth appli- ance control module. The receiver instruction may not be independent when part of the IFC. Figure 2: Transmitter LCD Display Figure 3: Battery Compartment Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 14 Transmitter LCD display will only show the room temperature (Fig. 6). At the same time the Receiver will turn off the appliance. A single “beep” from the Receiver confirms reception of the command. Figure 9 Figure 10 14 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 15 To de-activate this function, press the MODE and UP Keys at the same time. Keys (fig.1) to turn on, off or adjust the fan speed (fig. 14). A single “beep” will confirm reception of the command. Figure 18 Figure 13 Figure 14 Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 16 5. Use the up or down arrow button to program out the function on the remote. Note: You should never program out the fan (If installed) feature on the remote. It is not possible to remove the thermostat mode on this remote control. 16 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 17: Manufactured Mobile Home Additional Requirements

    Optional Brick Panels/Enamel Panels d. Log Set Installation e. Standard Flush Door f. Vignette Facepplate/Vignette Finishing Trim g. Louvers and Safety Screen h. Optional Wall Thermostat i. Optional Fan Installation Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 18: Clearances With Vignette Faceplate

    *See mantel clearance instructions. Mantel Leg Clearances with Vignette Faceplate Combustible mantel leg clearances from side of unit as per diagram: 18 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 19: Combustible Mantels

    Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. MANTEL CLEARANCES WITH MANTEL CLEARANCES WITH VIGNETTE + VIGNETTE FINISHING TRIM SAFETY SCREEN AND LOUVERS FLUSH FINISH MANTEL CLEARANCES WITH VIGNETTE + VIGNETTE FINISHING TRIM STEPPED FINISH Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 20: Framing And Finishing

    6" (15cm) with AstroCap termination cap or is 6" (15cm) with AstroCap termination cap or 12" (30cm) with Rigid Vent termination cap. (For 12" (30cm) with Rigid Vent termination cap. (For Example Dura-Vent). example Dura-Vent). 20 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 21 6) Use steel studs for framing where the 1-1/2" (38mm) clearance from the vent to combustible material cannot be maintained. The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details. Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 22: Wall Mount On/Off Switch And Remote Receiver Installation

    11. Using the two (2) screws provided secure the cover plate to the Receiver. Low Voltage Junction Box Profl ame Receiver J-Box Receiver Slider Switch Wall Plate 10 ft. wire harness with 12 pin connector Diagram 1 22 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 23: Unit Assembly Prior To Installation

    The P33-11 uses the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney. There are 5 vent systems approved for use with the P33-11: the Regency ®...
  • Page 24: Exterior Vent Termination Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally 24 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 25: Regency ® Direct Vent Flex System

    (4) Notes: spring 1) Liner sections should be continuous spacer without any joints or seams. 2) Only Flex pipe purchased from Regency ® 6-7/8" may be used for Flex installations. See Figure 1 below for (17 mm) Alternate Caps.
  • Page 26: Installation Procedures

    Installation Procedures for Regency Direct Vent System (Flex) ® 1) Locate the unit in the framing, rough in the gas *If this is an outside corner, the minimum distance between the vent and the outside (preferably on the right side of the unit) and the corner is 6"...
  • Page 27: Rigid Pipe Venting Systems

    Metal Products Ameri Vent Direct Vent, Security Secure Vent ® , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 28: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    Note: Olympia Ventis DV is only approved for certain models. See list of approved models in cross-reference chart. Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: Olympia Ventis DV venting is only approved for certain models. See list of approved models in cross-reference chart.
  • Page 29 46DVA-WFS TM-4TR VDV-FS04 * Not available from Regency ***Olympia Ventis DV application for the following units only when using 4" x 6-5/8" vent system: B36XTE, B36XTCE, all City Series 40 models, CV72E/CB72E (power-vented models only), G800C, G800EC, P36, P36E, RC500E.
  • Page 30: Rigid Pipe Venting Arrangements

    Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994). 30 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 31 Propane and Natural Gas. Maximum two 45 elbows allowed. • Vent must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 32 Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems. (Refer "Rigid Pipe Venting Sys- tems" Section) A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. Note: Regency Direct Vent System ® (Flex) is only approved for horizontal terminations.
  • Page 33 8 feet total horizontal. 3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 34 5' Min. 8' Max. 6' Min. 6' Max. 6' Min. For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. 34 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 35 5' Max. 7' Min. Please note min. 1 foot 5' Min. 6' Max. 8' Min. between 90 elbows is 6' Min. 7' Max. 9' Min. required. 7' Min. 8' Max. 10' Min. Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 36: Vertical Termination With Co-Linear Flex System In A Masonry Chimney

    3" Co-linear Adapter with flashing Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Rigid Pipe Adapter Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 36 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 37: Enting Arrangements - Vertical Terminations

    Venting Arrangements - Vertical Terminations with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Horizontal Distance (Feet) Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 38: Unit Installation With Horizontal Termination

    (Part # 620-926) over the vent pipe. **Note: Riser vent is only for use in above grade ** Note: Riser vent is only for use in above grade terminations. terminations. 38 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 39: Unit Installation With Vertical Termination

    Do not use open flame for leak testing. 8) Install the vertical termination cap by twist- locking it. Diagram 2 Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 40 10. Attach the rigid pipe section to the adaptor by using Mill-Pac on the inner/ Note: Any closets or storage spaces which the vent passes through must outer pipe. Use 3 screws to secure outer pipe. be enclosed. 40 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace 919-695 08.10.16...
  • Page 41: Vertical Flue Extension Kit (Part #946-756)

    Firestop spacer to prevent debris from falling into the ceiling Diagram 1 Roof support firestop Ceiling firestop Enclosure Ceiling firestop Diagram 1a Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ® 919-696 08.10.16 919-698 06.12.18...
  • Page 42: Pilot Adjustment

    Note: If you have an incorrect flame With Flush Glass: pattern, contact your Regency ® For 0 to 4500 feet altitude 1) Make sure the switch is in the "OFF" position.
  • Page 43: Conversion From Ng To Lp

    14. Check inlet and outlet pressures. installed. 15. Check operation of flame control. Remove the 2 screws holding the Burner Assembly to the firebox base. Push the Burner Assembly to the left and lift out. Installer Notice: These instructions must remain with the appliance. Remove the 2 screws, push Burner Assembly to the left and lift out. Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ® 01.14.19 920-029...
  • Page 44: Optional Enamel Panels

    Install the side panel pushing it toward the back- when in position the side panel should cover the flange on the back panel. Be very careful not to scratch them on the firebox hardware. Completed install 44 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace 03.01.21 919-641...
  • Page 45: Optional Brick Panels

    5) Slide the Top Brick Panel into position and slide the Top Brick Retaining clips so that they hold the Top Brick Panel in place and tighten down the screws. 2nd Grate Tab Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 46: Standard Flush Door

    See Diagram 2. 5th Grate Tab Diagram 1 46 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 47: Optional Birch Log Set Installation

    Logs A + B on a diagonal as shown below. The logs are fragile, handle with care—never force into position. 4. Sprinkle the vermiculite and embers around the fi rebox base. Vermiculite Vermiculite Vermiculite Install Log C Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ® 07.19.18 919-884...
  • Page 48 13. Test fi re to ensure proper light off (make sure fl ame fl ows smoothly from one end of burner to the other). If there is any fl ame hesita- tion, check that area for any burner ports blockage. 48 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace 919-884...
  • Page 49: Vignette Faceplate And Safety Screen Installation

    Vignette frame (see below). Screen below. assembly is secured at bottom with magnets. Screen Assembly Vignette Frame Reverse Steps to remove. Secure Vignette frame using 2 screws in locations shown below. Final Install Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 50: Optional Vignette Finishing Trim Install

    Hook Vignette Faceplate brackets into place. Line up the screw holes on the fi nishing trim and Vignette Face- plate bracket with the unit–fasten with one screw on each side– P33 only. 05.04.15 919-566 50 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 51: Optional Vignette Inlay Installation

    NOTE: Ensure Inlay is in correct position before pushing studs through the safety screen. Stud Nut + washer (supplied) Completed Install Line up Inlay–Push studs on Inlay through screen Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ® 05.21.15 919-559...
  • Page 52: Optional Finishing Trim

    Line up the screw holes on the finishing trim and Vignette Faceplate bracket with the unit–fasten with one screw on each side. Reinstall the glass door and safety screen. Finishing Trim Top Finishing Trim Side 52 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace 10.29.14 919-475...
  • Page 53: Safety Screen Installation

    4. Install bottom louver assembly by opening bottom louver enough to tighten screws. allow access to attach bottom louver brackets to unit with one screw on each side in locations shown below. Magnet locations 07.21.15 919-558a Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 54: Wiring Diagram

    CAUTION: Label all wires prior to disconnection hot surfaces and are away from sharp edges. when servicing controls. Wiring errors can cause improper and dangerous operation. 1 of 10 54 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 55: Optional Wall Thermostat Installation

    Unit will now operate using the wall thermostat. NOTE: When the remote receiver is set to ON position, the remote control transmitter and all of its features are now dis- abled. Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 56: Optional Fan Installation

    THESE FANS COLLECT A LOT OF DUST FROM WITHIN YOUR HOME. ENSURE YOU MAINTAIN THESE FAN MOTORS ON A REGULAR BASIS BY VACUUMING THE FAN BLADES AND THE HOUSING WITH A SOFT BRUSH NOZZLE. 56 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 57: Ac Power Adaptor Installation (For Surefire Systems)

    2. Tuck any loose wires neatly underneath the firebox–inside the fireplace. Note: Ensure that wires do not touch the underside of the fire box (Keep wires away from heat as much as possible). AC adaptor Wire adaptor Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ® 10/09/14 919-063...
  • Page 58: Wiring Diagram With Optional Fan

    Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. 58 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 59: Lighting Procedure

    2. Press and release the ON/OFF button on the remote handheld transmit- ter (see Diagram 2). An audible beep should be heard from the receiver. ON/OFF Button Diagram 2 Remote shown in Manual Mode on Hi Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 60: Copy Of The Lighting Plate Instructions

    Utiliser l'interrupteur mural ou la télécommande pour mettre le système sur ON/OFF. Appuyer sur la touche ''OFF'' de la télécommande. Mettre le bouton de commande de gaz sur ''OFF'' pour éteindre la veilleuse. DO NOT REMOVE THIS INSTRUCTION PLATE 919-401 60 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 61: Operating Instructions

    Note: When the glass is cold and the Note: Aeration Adjustment should only appliance is lit, it may cause be performed by an authorized condensation and fog the glass. Regency Installer at the time ® This condensation is normal and of installation or service.
  • Page 62: Maintenance Instructions

    3) Check for evidences of excessive your fan speed control. paint. Regency uses StoveBright Paint - Metal- ® condensation, such as water droplets forming lic Black #6309.
  • Page 63 Door Glass Flush Glass Replacement 1) with Vignette Faceplate installed: Remove Your Regency fireplace is supplied with high ® the Vignette safety screen and frame. See temperature, 5 mm Neoceram ceramic glass that Vignette instructions in this manual. will withstand the highest heat that your unit will produce.
  • Page 64: Removing Valve

    6) Disconnect the Electronic modulator, EV1, EV2, and ground wires Installing Valve from the valve - as shown below. 1) Install new valve assembly. Ground 2) Reverse steps 9 through 1. Electronic Modulator 64 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 65: Gas Appliance Maintenance

    Gas Maintenance Gas Appliance Maintenance Recommended Annual Routine Maintenance for Gas Fireplaces, Stoves and Inserts In order for your Regency appliance to continue to provide comfort to your home periodic maintenance must be performed to ensure it is operating at peak efficiency. The items in the list should be checked by a licensed gas service technician during the annual service check. Your unit may require more frequent maintenance checks if you notice any changes in how it operates. Operational changes to look for can include, but are not limited to, extended start up time, increased fan noise, residue/carbon build up, white build up on the glass/firebox, increased operating noise etc. Should any of these or other conditions arise, discontinue use and schedule a service check with your local licensed gas technician. The list below shows items your licensed service technician will need to check and service at least annually. Clean Inspect Check • Glass • Pilot assembly • Voltage on thermocouple/thermopile (mil- • Interior bricks / panels • Burner livolt models) • Burner ports & burner air shutter •...
  • Page 66: Main Assembly

    Brick Panel - Left Side Brick Panel - Right Side *Not available as a replacement part. Brick Panel - Top 430-056 Brick Clip - Top 439-908 Black Enamel Panel Set 66 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 67 HEAT WAVE DUCT KIT #946-556 BRICK PANEL SET FAN ASSEMBLY Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 68: Burner & Log Assembly

    Valve Assembly - NG 439-780E/P Valve Assembly - LP 910-036 Pilot Orifice - NG 910-037 Pilot Orifice - LP 438-977 Conversion Kit - LP *Not available as a replacement part. 68 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 69: Vignette Faceplate And Finishing Trim

    Vignette Faceplate Black Chrome 439-948 Vignette Door Inlay Black Chrome 439-924 Vignette Faceplate Black 439-949 Vignette Door Inlay Mt. Black 439-926 Vignette Faceplate Tuscan Sunset 439-950 Vignette Door Inlay Tuscan Sunset Parts Not Shown Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 70: Safety Screen And Louvers

    Safety Screen and Louvers Part # Description 439-920 Flush louvers black (Set) 439-929 Safety Screen 948-223 Regency Logo Plate ® 430-940 3-sided Finishing Trim 70 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 71 Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 72: Warranty

    FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. Revision Date: February 2019 Regency Gas Products Warranty 72 | Regency ®...
  • Page 73 Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ® Revision Date: February 2019 Regency Gas Products Warranty...
  • Page 74 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
  • Page 75 Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 77 Regency P33E-11 Zero Clearance Direct Vent Gas Fireplace ®...
  • Page 78 78 | Regency ® P33E-11 Zero Clearance Direct Vent Gas Fireplace...
  • Page 80 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial #: ____________________________________________________________ Printed in Canada Regency, Panorama, AstroCap and Surefire are trademarks of FPI Fireplace Products International Ltd. © Copyright 2021, FPI Fireplace Products International Ltd. All rights reserved.