Manufactured Mobile Home Additional Requirements; Installation Checklist; Locating Your Fireplace; Duct System Option - Regency PANORAMA P33E Owners & Installation Manual

Hide thumbs Also See for PANORAMA P33E:
Table of Contents

Advertisement

installation
|
10
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut or
weakened during installation.
2) Ensure proper grounding using the #8 ground
lug provided. Refer to "Wiring Diagram" Section.
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location
(Refer to "Locating Your Fireplace" Section)
b) Clearances to Combustibles
(Refer to "Clearances" Section)
c) Mantle Clearances
(Refer to "Combustible Mantels" Section)
d) Framing & Finishing Requirements (Refer
to "Framing & Finishing" Section)
e) Venting Requirements
(Refer to "Venting" Sections)
2) Assemble Top Facing Support and Side
Nailing Strips (Refer to "Unit Assembly Prior
to Installation" Section). NOTE: Must be done
before installing unit into fireplace.
3) Install vent (Refer to "Venting" Sections)
4) Make gas and electrical connections.
5) Install 4-AA batteries into receiver box/switch
box or use AC power adaptor supplied with
this appliance.
6) See remote control instructions for operations
of this device.
7) Test the pilot. Must be as per diagram.
(Refer to "Gas Line Installation" and "Pilot
Adjustment" Section).
8) Convert to Propane if desired.
(Refer to "Conversion Kit from NG to LP"
Section).
9) Install standard and optional features. Refer to
the following sections:
a. Optional Brick Panels
b. Log Set Installation
c. Standard Flush Door
d
Vignette Faceplate
e. Finishing Trim
f.
Optional Wall Thermostat
g. Installing the Optional Fan
h
Safety screen and Optional Louvers
10) Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to
customer.
10 |
Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace
This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.

LOCATING YOUR FIREPLACE

1) When selecting a location for your fireplace,
ensure that the clearances outlined on this
page are met.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the floor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed on
carpeting, combustible linoleum tile or other
combustible material other than wood flooring,
the appliance must be installed on a metal or
wood panel extending the full width and depth
of the appliance.
4) The P33E-10 can be installed in a recessed
position or framed out into the room as in A,
B, C, D. See Diagram 1 below.
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The P33E-10 Direct Vent Gas Fireplace is
approved for alcove installations, which meet
the clearances listed on the "Clearances"
Section.
7) We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before actually
installing this appliance. Have a qualified
inspector, dealer, or installer review your plans
before installation.
Note: For vent terminations see "Exterior Vent
Termination Locations" Section.
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
Diagram 1

DUCT SYSTEM OPTION

Kit #946-556
The HeatWave Air Duct Kit increases the
effectiveness of your fireplace by dispersing warm
air from the fireplace to remote locations in the same
room or other rooms in your home.
Up to two kits may be installed on the fireplace.
Please Note: Only 1 HeatWave kit may be oper-
ated at one time. This includes the internal blower
option as well.

Advertisement

Table of Contents
loading

Table of Contents