Horizontal Terminations - Regency PANORAMA P33E Owners & Installation Manual

Hide thumbs Also See for PANORAMA P33E:
Table of Contents

Advertisement

RIGID PIPE VENTING ARRANGEMENTS

Horizontal Terminations

REGENCY
DIRECT VENT SYSTEM (FLEX)
®
(Propane & Natural Gas)
This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45
elbow).
Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems. (Refer "Rigid Pipe Venting Systems" Section)
Minimum
Simpson Dura-Vent Center-Line
Maintain clearances to combustibles.
Horizontal vent must be supported every 3 feet.
Firestops are required at each floor level and whenever passing through a wall.
Minimum
Flex Kit Center-Line
Regency® P33E-10 Zero Clearance Direct Vent Gas Fireplace
installation
and one 90
elbow (two 45
elbows equal one 90
o
o
o
A vent guard should be used whenever the
termination is lower than the specified minimum
or as per local codes.
Note: Regency
Direct Vent System (Flex)
®
is only approved for horizontal
terminations.
|
25
o
|
25