WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
919-246
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
P33-5 Zero Clearance
MODELS:
P33-NG5 Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
P33-LP5 Propane
FOR YOUR SAFETY
What to do if you smell gas:
 Do not try to light any appliance
 Do not touch any electrical switch:
do not use any phone in your
building.
 Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
 If you cannot reach your gas
supplier, call the fi re department.
6988 Venture St., Delta, BC Canada, V4G 1H4
Owners &
Installation Manual
www.regency-fi re.com
06/03/13

Advertisement

Table of Contents
loading

Summary of Contents for Regency P33-5

  • Page 1 P33-5 Zero Clearance Owners & Installation Manual Direct Vent Gas Fireplace www.regency-fi re.com MODELS: P33-NG5 Natural Gas P33-LP5 Propane WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: ...
  • Page 2 You are the owner of a state-of-the-art Gas Fireplace by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The P33-5 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
  • Page 3 This appliance is only use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 4: Table Of Contents

    Conversion from NG to LP ........34 Optional Brick Panels ..........37 Log Set Installation ............ 37 Standard Flush Door ..........38 Flush Louvers ............39 Full Screen doors ............40 ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 5: Safety Label

    Delta, BC, Canada Standard in Canada. VENTILATION : Système de GS de Dura-conduit de Simpson énuméré par utilisation ou circuit de mise à l'air libre direct de Regency. Made in Canada/ Seulement pour la décharge directe sans connexion de conduit. Cet appareil \ndoit être installé selon les instructions d'installation du fabricant Fabrique au Canada et avec des codes locaux éventuels ;...
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 7: Important Message

    Refer to "Wiring Diagram" Section. the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 8: Installation Checklist

    (Refer to "Venting" Sections) and depth of the appliance. Please Note: Only 1 HeatWave kit may be 4) The P33-5 can be installed in a recessed operated at one time. This includes the internal 2) Assemble Top Facing Support and Side position or framed out into the room as in blower option as well.
  • Page 9: Unit Dimensions

    INSTALLATION UNIT DIMENSIONS UNIT DIMENSIONS WITH CONTEMPORARY FACEPLATE 23"(584mm) 33"(838mm) 33"(838mm) 12-3/4"(324mm) ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 10: Clearances For Flush Front

    Horizontal - Bottom 1-1/2" (room and/or alcove) Vertical (Flex Vent) 1-1/2" D: Alcove Width 48" (1219mm) Sidewall to Sidewall (Minimum) Vertical (Rigid) 1-1/4" E: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 11: Combustible Mantels

    Mantel Clearances with Mantel Clearances Contemporary Faceplate with Flush, Full Screens or Bay Glass Drywall 12" (305mm) 7-1/2"(191mm) 0” - 3-1/2" (89mm) 11"(279mm) 9"(229mm) 7"(178mm) Top of Unit 29"(737mm) to floor Side View ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 12: Mantel Leg Clearances With Flush Glass

    Combustible mantel leg clearances from side of unit as per diagram: Maximum 1-1/2" projection at 2" minimum clearance. MANTEL LEG CLEARANCES WITH CONTEMPORARY FACEPLATE Combustible mantel leg clearances from side of unit as per diagram: ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 13: Framing And Finishing

    You must maintain clearance from faceplate option. the vent to combustible materials See framing section when using faceplate in for fl ex or for Rigid Vent (Refer to this manual. "Clearances" Section). ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 14: Framing Dimensions With Contemporary Faceplate

    Vent Centerline Height* 30" (762mm) Rigid 26" (660mm) Flex Gas Connection Height* 1 1/2" (38mm) Gas Connection Inset* 4" (102mm) Gas Connection Width* 3" (76mm) * Measured from base of unit. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 15: Framing & Finishing With Contemporary Faceplate

    P33-5 unit. Note: Unit must be raised up by 1' to allow for faceplate installation. Current P33-5 orifi ce size: #44 #55 Must replace with: #47 #56 Warning: Fire hazard is an extreme risk if these changes are not adhered to.
  • Page 16: Unit Assembly Prior To Installation

    VENTING INTRODUCTION The P33-5 uses the "balanced fl ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
  • Page 17: Exterior Vent Termination Locations

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 18: Regency ® Direct Vent Flex System

    Horizontal Terminations Only This venting system, in combination with the P33-5 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey/ Intertek. The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" Section .
  • Page 19: Installation Procedures

    2 x 4 or 2 x 6 walls. The liners must slip over the collars a minimum of 1-3/8". Wall Thimble 2 pieces (10" (254mm) Outer Diameter) ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 20: Rigid Pipe Venting Systems

    American Metal Products Ameri Vent Direct Vent, Security Secure Vent , Selkirk Direct-Temp. AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 21: 4" X 6-5/8" Rigid Pipe Cross Reference Chart

    Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. 4” X 6- 5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Description...
  • Page 22 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 23: Rigid Pipe Venting Arrangements

    Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles. • When using Contemporary Faceplate, unit must be raised 1". Note: Must use optional rigid pipe adapter when using rigid vent systems (Part # 510-994). ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 24 INSTALLATION The P33-5 is approved for a maximum 40 ft. straight vertical, with rigid pipe vent systems for Propane and Natural Gas. The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas.
  • Page 25 Firestops are required at each fl oor level and whenever passing through a wall. • When using Contemporary Faceplate, unit must be raised 1". Minimum Minimum Flex Kit Center-Line Simpson Dura-Vent Center-Line ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 26 3' Max. 4' Min. 6' Max. Please note minimum 4' Max. 6' Min. 7' Max. 1 foot between 90 elbows is required. 5' Max. 8' Min. 8' Max. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 27 1 foot between 90 6' Max. 6' Min. elbows is required. 5' Min. 8' Max. 6' Min. For additional vertical venting with 2 x 90 elbows, refer to "Rigid Pipe Venting Arrangements" Section. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 28 5' Max. 7' Min. horizontal. 5' Min. 6' Max. 8' Min. Please note min. 1 foot 6' Min. 7' Max. 9' Min. between 90 elbows is required. 7' Min. 8' Max. 10' Min. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 29: Vertical Termination With Co-Linear Flex System

    3" Co-linear Adapter with fl ashing Outer Pipe with Kit# 946-563 Air Intake Pipe Length Co-Linear Flex Rigid Pipe Adapter Adapter # 510-994 with Kit# 946-563 45 Elbow Inner Pipe Adapter with Kit# 946-563 ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 30: Venting Arrangements - Vertical Terminations

    Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Horizontal Distance (Feet) When using Contemporary Faceplate, unit must be raised 1". The shaded area in the diagrams show the allowable vertical terminations. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 31: Unit Installation With Horizontal Termination

    Failure to do so may Thimble (Part # 620-926) over the vent result in drafting or performance issues not pipe. covered under warranty. Silicone (red RTV) is optional. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 32: Unit Installation With Vertical Termination

    fl ashing to the roof with roofi ng rails, detector. Do not use open fl ame for leak slide storm collar over the pipe section and testing. Diagram 2 seal with a mastic. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 33: Pilot Adjustment

    2) Manual high/low adjustment 3) Pilot Adjustment 4) Thermocouple Connection - option 5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) Alternative TC Connection Point ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 34: Conversion From Ng To Lp

    INSTALLATION CONVERSION KIT# 435-969 FROM NG TO LP For P33-5 Using SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Each Kit contains one LPG Unscrew the pilot orifi...
  • Page 35 10) Check that the screw is clean and if necessary remove dirt. 11) Flip the screw (Fig. 3). Fig. 6 WARNING! Also check that the pilot and main burner injectors Fig.3 are appropriate for the gas type. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 36 14) Tie up the loose wire with the wire clip. Locate the ground lug at the receptical 10) Connect the ground wire to the DC box, left of the unit. Sparker mounting bracket. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 37: Optional Brick Panels

    5) Slide the Top Brick Panel into position and slide the Top Brick Retaining clips so that they hold the Top Brick Panel in place and tighten down the screws. 2nd Grate Tab ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 38: Standard Flush Door

    See Diagram 2. 5th Grate Tab ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 39: Flush Louvers

    Push down to lock into place. Tighten the screws. Screws on Burner ON/OFF louver bracket control box Burner ON/OFF control box attached to bottom fl ush louver. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 40: Full Screen Doors

    3) Before attaching the Full Screen Door Frame, remove the Screen Doors from the Full Screen Door Frame by fully opening the doors Cut-Outs and lifting up off of the hinges. See important note in step 10. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 41 7) Mount the Burner ON/OFF Control Box to the left side of the Bottom Grill using 2 x #8 - 1/4" Philips Head Screws. Left Side of Bottom Grill Screen Door Burner ON/OFF Control Box 11) Close screen doors. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 42: Contemporary Faceplate Installation Part 1

    Note: Place Decal Derating P33-4 (918-777) to decal plate by overlaying existing decal located on the front side base of the unit. * For conversion from NG to LP refer to the NG to LP conversion section in the P33-4 manual. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 43: Contemporary Faceplate Installation Part 2

    3) Connect fan ground cable to ground lug. Refer to wiring diagram. fan blades and housing using a soft brush nozzle. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 44: Contemporary Faceplate Installation Part 3

    5) The top of the faceplate has a fl ange that hooks over the top of the fl ush door. Heat Defl ector Diagram 6 Flange Faceplate Support Control Shield Mounting Frame Diagram 3 ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 45 Diagrams 7 & 8. Diagram 7 Faceplate Diagram 8 Faceplate Support Image of P33-5 with Faceplate Image of P33-4 with Faceplate Image of P33S with Faceplate Diagram 9 ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 46: Optional Remote Control

    4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 47: Wiring Diagrams

    NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case the fan is installed at a later date. NATURAL GAS Units and Units Equipped with DC Spark Boxes ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 48 Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 49: Installing The Optional Fan

    Push hold-down clip onto inside louver and press tab until it is at 90 to louver. Diagram 1 ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 50: Copy Of The Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 51: Operating Instructions

    The pilot fl ame should continue to burn. and will disappear in a few minutes as If the pilot does not remain lit, repeat operation the glass heats up. allowing a longer period before releasing gas ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 52: Maintenance Instructions

    Log Installation. Note: Improper positioning of logs may create carbon build-up and will severely alter the unit's performance which is not covered under warranty. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 53: Thermopile/Thermocouple

    Flush Front (Part # 936-155). DOOR GLASS ® Your Regency fi replace is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce.
  • Page 54: Removing Valve

    10) Undo the pilot tube from the valve with a 18) Fire up the unit again and check for proper fl ame screws Rear Log Stand appearance and glow on logs. Diagram 2: Rear Log Stand & Valve Tray Assembly ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 55: Main Assembly

    MAIN ASSEMBLY Part # Description Part # Description Part # Description 946-556 Optional Heat Wave Duct Kit 1) 948-247 Door Handle 432-901 Brick Panel Set - Standard Brown 89) 946-004 Junction Box 2) * Thermodisc Bracket 432-902 Brick Panel Set - Standard Red 90) 946-000 Round Duct Adaptor 432-903...
  • Page 56 PARTS LIST HEAT WAVE DUCT KIT ON-OFF SWITCH ASSEMBLY BRICK PANEL SET FAN SWITCH ASSEMBLY DOORS & LOUVERS PLEASE REFER SEPARATE SECTION ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 57: Burner & Log Assembly

    Burner Grate Assembly - NG/LP 83) * Rear Log Support Bracket - NG/LP 85) 431-930 Log Set 86) 430-097 Air Defl ector-Left 87) 433-018 Air Defl ector-Right *Not available as a replacement part. ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 58: Flush Front & Louvers

    137) 904-691 U-Clip 139) 936-155 Glass Gasket (Tadpole) 140) 948-042 Spring Hinge - Black 430-940 Finishing Trim (Set) - Black (Option) 157) * Finishing Trim Left 159) * Finishing Trim Right ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 59: Contemporary Faceplate

    Bumper Rubber W/Machine Screw 8-32 x 3/8" 904-925 Cap Assy Brushed Stainless 3/4" diameter. 434-032 Control Shield 434-018F Heat Defl ector 904-434 Burner Orifi ce #47 (Natural Gas) 904-241 Burner Orifi ce #56 (Propane Gas) ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 60 NOTES ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 61 NOTES ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 62 NOTES ® Regency P33-5 Zero Clearance Direct Vent Gas Fireplace...
  • Page 63: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 64 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency, Panorama, AstroCap are trademarks of FPI Fireplace Products International Ltd. © Copyright 2012, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

P33-ng5P33-lp5