Konica Minolta bizhub 200 Service Manual page 520

Hide thumbs Also See for bizhub 200:
Table of Contents

Advertisement

Field Service Ver. 2.5 Jul. 2006
MODE
Bit:
371
Bit
Feature
7
Retry interval for "number
of times to retry addi-
6
tional E-mail transmis-
5
sion" (Network function)
4
SMTP server switching
1
1
Binary Division *
0
Page Division *
NOTE
• The features with (*) are settable by users. *: Screen setting
MODE
Bit:
372
Bit
Feature
7
Specify transmission
interval of sizedivided E-
6
mail file data <*>
5
4
3
2
1
0
NOTE
• The features with (*) are settable by users. <*>: Soft switch setting
Confidential – for internal use only, do not distribute
Factory setting bit
7 6 5 4
3 2 1 0
0 1 0 0
0 0 0 0
Logic
0
1
Bit 7-5:
000
001
010
011
100
Others
OFF
ON
OFF
ON
OFF
ON
Factory setting bit
7 6 5 4
3 2 1 0
0 0 0 0
1 1 1 1
Logic
0
1
Bit 7-0:
00000101 5 sec
00001010 10 sec
00001111 15 sec
00011110 30 sec
00111100 60 sec
01011010 90 sec
01111000 120 sec
10010110 150 sec
10110100 180 sec
11010010 210 sec
11110000 240 sec
00000000 Not available
11. Soft Switch
HEX:40
Description
10 min
15 min
20 min
25 min
30 min
Not available
Register two SMTP servers and specify
whether or not to switch at the time of
TX error.
HEX:0F
Description
123

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 250Bizhub 350

Table of Contents