During the knife calibration routine, the cutter will cut a series of test patterns which allow
the user to identify errors in the knife rotation and concentricity. Use the touch screen to
make corrections.
Setting tangential knife parameters:
1. Power on the cutter, load the media and mount the drag knife (see section 1.7.2.1.)
Origin
Pause
Configuration 1
Media size
50000 x 718 mm
Tool
Tangential knife
Velocity
800 mm/s
Knife pressure
95 gr
Summa USB port 1
Summa USB port 1
2. Press on Settings
4. Click on the parameter that needs to be changed.
The selected parameter will be highlighted in cyan on the touch screen.
5. Use
The value (inverse) will change.
1. Press
2. Press
Basic Operation
ORIGIN deviation
LATERAL deviation
FIG 2-5
2-5

POSSIBLE KNIFE CALIBRATIONS

Settings
Tool
Tangential knife
Velocity
Knife pressure
Calibrate knife
Actions
FlexCut
General
Advanced cutting
Settings
3.
Press on Calibrate knife.
to change the value of the parameter.
Test
to perform the internal knife calibration test.
Apply
to confirm and exit the knife calibration menu.