Raritan MCCAT18 User Manual

Raritan MCCAT18 User Manual

Hide thumbs Also See for MCCAT18:
Table of Contents

Advertisement

Quick Links

MasterConsole
MCCAT18/MCCAT116
CAT

User Guide

Release 1.1
 
 
Copyright © 2007 Raritan, Inc. 
MCCAT‐0B‐E 
December 2007 
255‐20‐0002‐00 

Advertisement

Table of Contents
loading

Summary of Contents for Raritan MCCAT18

  • Page 1: User Guide

    MasterConsole MCCAT18/MCCAT116 User Guide Release 1.1     Copyright © 2007 Raritan, Inc.  MCCAT‐0B‐E  December 2007  255‐20‐0002‐00 ...
  • Page 2 This document contains proprietary information that is protected by copyright. All rights reserved.  No part of this document may be photocopied, reproduced, or translated into another language  without express prior written consent of Raritan, Inc.  © Copyright 2007 Raritan, Inc., CommandCenter®, Dominion®, Paragon® and the Raritan company  logo are trademarks or registered trademarks of Raritan, Inc. All rights reserved. Java® is a registered  trademark of Sun Microsystems, Inc. Internet Explorer® is a registered trademark of Microsoft  Corporation. Netscape® and Netscape Navigator® are registered trademarks of Netscape  Communication Corporation. All other trademarks or registered trademarks are the property of their  respective holders.  FCC Information This equipment has been tested and found to comply with the limits for a Class A digital device,  pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection  against harmful interference in a commercial installation. This equipment generates, uses, and can  radiate radio frequency energy and if not installed and used in accordance with the instructions, may  cause harmful interference to radio communications. Operation of this equipment in a residential  environment may cause harmful interference.  VCCI Information (Japan) Raritan is not responsible for damage to this product resulting from accident, disaster, misuse, abuse,  non‐Raritan modification of the product, or other events outside of Raritanʹs reasonable control or not  arising under normal operating conditions.     ...
  • Page 3 Power Safety Guidelines To avoid potentially fatal shock hazard and possible damage to Raritan equipment:  • Do not use a 2‐wire power cord in any product configuration.  • Test AC outlets at your computer and monitor for proper polarity and grounding.  • Use only with grounded outlets at both the computer and monitor. When using a backup UPS,  power the computer, monitor and appliance off the supply.  Rack Mount Safety Guidelines In Raritan products which require Rack Mounting, please follow these precautions:  • Operation temperature in a closed rack environment may be greater than room temperature. Do  not exceed the rated maximum ambient temperature of the appliances.  • Ensure sufficient airflow through the rack environment.   • Mount equipment in the rack carefully to avoid uneven mechanical loading.  • Connect equipment to the supply circuit carefully to avoid overloading circuits.   • Ground all equipment properly, especially supply connections, such as power strips (other than  direct connections), to the branch circuit. ...
  • Page 4: Table Of Contents

    Contents Chapter 1 Introduction Product Overview ............................. 1 Product Photos............................1 Product Features............................2 Package Contents ............................3 Chapter 2 Quick Start A Glance at the Product..........................4 Front View............................4 Rear View ............................5 Connecting Computers..........................6 Selecting a Channel ........................... 9 Front Panel Operation ........................9 OSD Operation ..........................10 Changing Channel Names ........................11 Chapter 3 Introduction to the On-Screen Display (OSD) Activating the OSD ..........................
  • Page 5 STEP 1: Download the Latest Firmware and Upgrade Utility ............40 STEP 2: Connect the MCCAT Unit to the Computer Running the Upgrade Utility ...... 41 STEP 3: Launch the Upgrade Utility..................... 42 STEP 4: Power Cycle the Upgraded MCCAT Unit ................44 Appendix A Specifications Measurement ............................45 Supported Resolutions..........................45 Appendix B MCCAT Default Settings Appendix C Compatibility with Other Raritan Products Compatible CIMs............................. 47 Connecting a Serial Device via the Serial CIM................. 48 Compatibility with MasterConsole II ....................49 STEP 1: Programme a MasterConsole II Unit as a Second‐Tier Device........ 49...
  • Page 6 Contents STEP 2: Connect the Second‐Tier MasterConsole II Units............50 STEP 3: Specify the Type of the Connected Second‐Tier Device in the OSD....... 50 Appendix D Troubleshooting Index...
  • Page 7: Chapter 1 Introduction

    Chapter 1 Introduction Congratulations on purchasing a Raritan MasterConsole CAT KVM  (keyboard/video/mouse) switch. This User Guide explains how to use  these KVM switches to access and control multiple computers (or  servers).  In This Chapter Product Overview....................1  Product Photos ....................1  Product Features ....................2  Package Contents....................3  Product Overview MasterConsole CAT (MCCAT) is a product that allows control of  multiple computers from a single keyboard, mouse and monitor. All you  need to do is simply connect the keyboard, mouse, monitor and multiple  computers to an MCCAT unit, and you will be able to switch between  various computers. The product features the use of the standard  Category 5 (Cat5) unshielded twisted‐pair (UTP) cabling, and the number  of the accessible computers can be expanded to a maximum of 256  computers with a two‐tier cascaded system.  In terms of operation, the product provides front panel buttons for easy  and fast access to the attached computers in addition to a friendly OSD  interface for simple system configuration.  Product Photos Model: MCCAT18 (Front and Rear View)     ...
  • Page 8: Product Features

    Product Features Model: MCCAT116 (Front and Rear View)      Product Features • One user can control up to 16 computers per unit. The number of  computers that can be controlled varies depending on the model  purchased:  MCCAT18: allows control of 8 computers  MCCAT116: allows control of 16 computers ...
  • Page 9: Package Contents

    Chapter 1: Introduction • A maximum of 256 computers can be controlled in a two‐tier  cascaded MCCAT system  • The unit interconnects with each computer via the standard Cat5  UTP cables  • The units can be cascaded to form a two‐tier KVM switch system  • The OSD interface features simple system control and management  • Support the video resolution up to 1600x1200  • The user can be located at a distance up to 100 feet (30.4 meters) from  the attached computers  • With the “keep‐alive” technology, users can add, remove and  hot‐swap components without interruption to the computers.  • LEDs in the front panel indicate the status of computers  • Buttons in the front panel provides fast access to computers  • Multi‐platform support, including MS‐DOS, Windows  2000/2003/NT/Me/XP/Vista, Linux (Red Hat, Novell Suse) and SCO  Unix  • Support IBM, Dell and HP servers  • The Scan function allows the system to automatically cycle through  all of the channels at the default or user‐customized rates  • The Skip function allows the system to bypass inactive channels  during the channel scanning  • The Password Security function, providing one administrator and 5  user passwords, prevents unauthorized access to the attached  computers ...
  • Page 10: Chapter 2 Quick Start

    This chapter addresses only the basic connections for setting up an  MCCAT system and basic operations for interacting with the computers  being connected to the system. For advanced hardware installation or  OSD operations, refer to Chapter 4: Advanced Operation and System  Configuration (on page 17) and Chapter 5: Two‐Tier System (on page 32)  for details.  In This Chapter A Glance at the Product ..................4  Connecting Computers ..................6  Selecting a Channel ...................9  Changing Channel Names................11  A Glance at the Product This section briefly introduces the components on the front and rear sides  of the MCCAT unit and the initial OSD menu that you will see after the  product starts to work.  Front View The front panel provides the model number for identification and push  buttons for convenient operation of frequently used functions.    Component Description   CAT18 indicates the unit is MCCAT18.  Model name  CAT116 indicates the unit is MCCAT116.    SKIP button  Toggles AutoSkip on/off.  When the AutoSkip function is on, the system skips inactive  channels and accesses active ones only. ...
  • Page 11: Rear View

    Chapter 2: Quick Start   SCAN button  Toggles AutoScan on/off.  When the AutoScan function is on, the system automatically  cycles through all channels until the function is turned off.    Channel buttons  These buttons enable immediate access to the computer  connected to the corresponding channel. In addition, each  channel button can show each channelʹs status through its LED  color change.  • Off: Either no device is connected to the channel, or the  connected device is NOT powered.  • Orange: A device, which is powered, is connected to the  channel.  • Green: The channel is being selected and accessed.    TIER LED  Shows the unitʹs tier status.  • Off: The MCCAT unit is programmed as the first‐tier device.  This is the factory default.  • On: The unit is programmed as the second‐tier device. For  details about setting the unit as the second‐tier device, see  Setting Up a Two‐Tier System (on page 33).  Rear View The rear side comes with a number of connectors for attaching various  devices or cables, such as the monitor.    Component Description  ...
  • Page 12: Connecting Computers

    Connecting Computers   Admin port  Connects to a computer via a serial cable for upgrading the  MCCATʹs firmware.    HD15 video port  Connects to a monitor for displaying the MCCAT OSD and the  video of the accessed computer.    Channel ports  Connect to computers via standard Cat5 UTP cables. The number  of available channels varies depending on the model you  purchased.  Connecting Computers Prepare the following components or devices before connecting  computers to the MCCAT unit:  Cat5 UTP cables (one cable per computer)  Computer Interface Modules (CIMs): MCIM‐PS2 or MCIM‐USB  (one CIM per computer)  A standard keyboard  A standard 2‐wheel mouse  A standard monitor  Note: For better video quality, the use of “Belden” Cat5 UTP cable is strongly  recommended.  1. Make sure the MCCAT unit and all devices are powered OFF,  including the monitor and computer(s) that you want to connect.  2. Attach a PS/2 or USB CIM to the computer:  If the CIM is a PS/2 CIM:  Connect the PS/2 mouse connector of the CIM to the PS/2 mouse  port of the computer.  Connect the PS/2 keyboard connector of the CIM to the PS/2  keyboard port of the computer. ...
  • Page 13 Chapter 2: Quick Start Connect the HD15 video connector of the CIM to the HD15 video  port of the computer.    If the CIM is a USB CIM:  Connect the USB connector of the CIM to one of the USB ports of  the computer.  Connect the HD15 video connector of the CIM to the HD15 video  port of the computer.   ...
  • Page 14 Connecting Computers 3. Use a Cat5 UTP cable to connect from one of the channels ports of the  MCCAT to the RJ45 port of the CIM being connected to the computer.    4. Repeat Steps 2 to 3 if you want to connect more computers.  5. Connect a keyboard, mouse and monitor to the MCCAT unit.  a. Connect the mouseʹs connector to the PS/2 mouse port of the  MCCAT unit.  b. Connect the keyboardʹs connector to the PS/2 keyboard port of  the MCCAT unit.  Connect the monitorʹs connector to the HD15 video port of the  MCCAT unit.  d. Connect the monitorʹs power cord to the appropriate power  outlet.   ...
  • Page 15: Selecting A Channel

    Chapter 2: Quick Start 6. Connect one end of the MCCATʹs power cord to its power jack and  the other end to the appropriate power outlet.    7. Power on the monitor, connected computer(s) and the MCCAT unit.  Selecting a Channel After finishing the hardware installation, try to access one or more  channels to verify the connections. Use one of the following to access  channels:  • Front panel buttons  • OSD  Note: If you establish a two‐tier MCCAT system, the only way to access the  second‐tier channels is through the OSD. For more information, see Chapter 5:  Two‐Tier System (on page 32).  Front Panel Operation Press the channel button whose number corresponds to the channel you  want to access. The video of the accessed channel appears on the screen  and you can control the computer with the keyboard and mouse attached  to the MCCAT unit.   ...
  • Page 16: Osd Operation

    Selecting a Channel Note: The front panel operation becomes invalid if the OSD remains displayed on  the screen. Therefore, make sure the OSD is NOT onscreen when operating with  the front panel buttons.  OSD Operation 1. Press the hot key twice QUICKLY (default: Scroll Lock) to activate  the OSD.  2. The Selection Menu similar to the following image appears, with eight  channels shown on one page. Note that the default name PC<XXXX>  (<XXXX> indicates the channel number) appears only when the  MCCAT unit detects that a device is being connected to the channel.    3.  (Optional) Press Page Down or Page Up to switch between pages if  your MCCAT contains more than eight channels and the desired  channel is not on the current page.  4. Press   or   to move the yellow highlight bar to the desired channel,  or simply press the corresponding “Key” number of that channel to  immediately access it.  5. Press Enter and the video of the accessed channel appears on the  screen. ...
  • Page 17: Changing Channel Names

    Chapter 2: Quick Start Now you can control the computer with the keyboard and mouse  attached to the MCCAT unit.  Warning!! MCCAT does not support real‐time channel detection when  channel changes occur. Therefore, if you disconnect the computer from  the channel you are accessing now and reconnect another computer to  that channel, you must activate the OSD to select the same channel  again. Otherwise, you may have mouse or keyboard input issues with  the channel being accessed.  Changing Channel Names By default, the connected device or computerʹs name is shown  “PC<XXXX>,” and a second‐tier MCCAT unitʹs name is shown  “/MCCAT<XX>” in the On‐Screen Display (OSD). <XXXX> or <XX>  indicates the channel number but may not be meaningful for you to  identify the connected device. Therefore, it is recommended to change the  default channel name(s) for better identification.  1. (Optional) If the OSD is not onscreen, press the hot key twice  QUICKLY (default: Scroll Lock) to activate it. The Selection Menu  appears.   ...
  • Page 18 Changing Channel Names 2. Press F3 to go to the Edit Names and Scan Rate menu.    3. Press the arrow keys ( ,  ,  ,  ), Tab or Shift+Tab to select the  desired channel name. The selected character blinks, indicating  where the selection is.  4. Type the new name up to eight characters and each blinking  character is replaced. However, a second‐tier device does not allow you  to change its first character “/” so you can only type up to seven  characters for such a device name.  5. If there are more than one device or computerʹs name to modify,  repeat Steps 3 to 4.  6. Press Esc to exit the current OSD menu.  7. The message “Save the changes: [Y/N]” appears on the message bar.  Press Y to save the new name(s) or N to abort the name(s).    The OSD returns to the Selection Menu. Verify if the names have been  changed successfully. ...
  • Page 19: Chapter 3 Introduction To The On-Screen Display (Osd)

    Chapter 3 Introduction to the On-Screen Display (OSD) The product provides a simple OSD user interface for both of the channel  selection and system configuration. In addition, the OSD shows  information relevant to the MCCAT unit or the channel being accessed.  In This Chapter Activating the OSD..................13  OSD Layout ......................13  Frequently Used Keys ..................14  OSD Menus.......................14  Introduction to the Selection Menu...............15  Activating the OSD To activate the OSD, press the systemʹs hot key twice QUICKLY. The  default hot key is Scroll Lock. You can change it in the Configuration  Menu. For more information, see System Configuration (on page 26).  OSD Layout The OSD interface usually has a layout like this:      Current menuʹs title    The area of system data or configuration fields    Function keys that can be used while the OSD is onscreen ...
  • Page 20: Frequently Used Keys

    Frequently Used Keys   Message bar, which shows the options or keys that are applicable to the selected field, or  shows prompt messages for the action being performed  Frequently Used Keys The following keys are frequently used with the OSD operation.  • Tab and Shift+Tab: These keys allow you to move between fields.  • Arrow keys ( ,  ,  ,  ): These keys, usually the Up and Down  arrow keys, are mainly used to change the numeric values or to  switch between available options of the selected field. However,  sometimes they can also be used to move between fields or  alphanumeric characters, such as the Edit Names and Scan Rate menu.  • Esc: Press this key when quitting the current OSD.  OSD Menus The OSD interface provides five menus in total. You can go to any of  them by pressing a specific function key when the OSD is onscreen.  Function Menu Description F1  Help Menu  Shows all available function keys and the productʹs  firmware version  F2  Selection Menu  Lists all channels for channel selection and shows each  channelʹs scan time for ʺIndividual scan modeʺ  F3  Edit Names and Scan ...
  • Page 21: Introduction To The Selection Menu

    Chapter 3: Introduction to the On-Screen Display (OSD) Introduction to the Selection Menu The Selection Menu, showing all channels of the system, allows you to  access channels.  Besides, it displays the scan time setting for ʺIndividual  scan modeʺ of each channel . Every time when you activate the OSD, the  system always displays the Selection Menu similar to the image below.    Field Meaning Description MC  Name of the MCCAT  The default is the model name: MCCAT18 or MCCAT116. This  unit  name can be customized and it helps you identify the current  MCCAT unit if more than one unit exist in the system. For more  information, see System Configuration (on page 26).  Page  Page information  Page information comprises two parts: ʺcurrent pageʺ and ʺtotal  number of pages.ʺ Each page displays a maximum of eight  channels.  Key  Selection number for  Pressing this number in the keyboard allows you to access the  the channel  desired channel immediately.  Ch. ID  Channel port number  This is the number of the channel where the computer or device ...
  • Page 22: Switching Between

    Introduction to the Selection Menu Field Meaning Description Name  Name of the device or  If there is any computer or device connected to the channel, the  computer connected to  default name is PC<XXXX>, where <XXXX> indicates the  the channel  channel number. For example, the computer connected to  channel number 3 is shown PC0003. The name can be changed.  For more information, see Changing Channel Names (on page  11).  Status  Channel status  It is always shown +S<XX> and has two meanings:  • The appearance of this channel status indicates the channel  is active while its absence indicates the channel is inactive. • <XX> indicates the scan time setting of the single channel  for “Individual” scan mode and the unit of the scan time is  in seconds.  Switching between Pages If there are more than one page of channels, use the following keys to  change pages:  • Press Page Up or Page Down to go to previous or next page.  • Press Home or End to go to the first or the last page. ...
  • Page 23: Chapter 4 Advanced Operation And System Configuration

    Chapter 4 Advanced Operation and System Configuration In this chapter, you will learn more about the OSD or front panel  operations for advanced features, such as updating the channel status,  setting up the security feature, etc.  If your MCCAT is a two‐tier system, you must perform these operations  on the first‐tier MCCAT unit. Make sure you have programmed all of the  second‐tier MCCAT units as the second‐tier devices; otherwise, any  operation or setting you have done will apply to the first‐tier MCCAT  unit only instead of the whole system. For information on how to  programme an MCCAT unit as a second‐tier device, see STEP 1:  Programme an MCCAT Unit as a Second‐Tier Device (on page 33).  Note: In a two‐tier system, SCAN, SKIP and channel buttons of all second‐tier  devices are disabled. However, these buttons work properly on the first‐tier  MCCAT unit.  In This Chapter Toggling the Channel Sorting ................17  Cycling Through Channels................19  Returning to the Previous Channel ...............21  Refreshing the Channel Status ...............22  Accessing Active Channels Only..............22  The Security Feature..................23  Changing the Keyboard Layout Setting ............25  System Configuration ..................26  Accessing the Help Menu................30  Resetting the System ..................31  Toggling the Channel Sorting The OSD Selection Menu can sort channels by two ways: channel numbers ...
  • Page 24 Toggling the Channel Sorting 2. If the current OSD menu is not the Selection Menu, press F2 to have  the Selection Menu displayed.    3. Press F12 to toggle the sorting.    TIP: When the channels are sorted by channel name, you can type the first  character of the name of the desired channel, the system will jump to the channel  whose name begins with the same character. ...
  • Page 25: Cycling Through Channels

    Chapter 4: Advanced Operation and System Configuration Cycling Through Channels Instead of manually selecting the desired channel to view its video, you  can activate the AutoScan function to make the MCCAT system  automatically display the video of all channels one after another.  There are two types of AutoScan modes: Global and Individual. The  default AutoScan mode is Global. Their differences are described below:  • Global scan mode:   The scan time for each channel is the same and it is based on the  setting configured in the Configuration Menu.  • Individual scan mode:   The scan time for each channel can be different and it is based on the  settings configured for each channel in the Edit Names and Scan Rate  menu.  For instructions on changing the scan mode and time, see System  Configuration (on page 26) later in this chapter.   You can activate the AutoScan function with one of the following ways:  • Front panel buttons  • OSD  Front Panel Operation 1. (Optional) If the OSD remains displayed on the screen, quit it by  pressing the Esc button.  2. Press the SCAN button on the front panel. The LED under the button  is lit.   ...
  • Page 26: Osd Operation

    Cycling Through Channels Turn off AutoScan  Press the SCAN button so the LED light is off. The system will stop at the  last scanned channel.  Cycling Through Active Channels Only When AutoScan is on, the system cycles through all channels, including  ʹactiveʹ and ʹinactiveʹ ones. To shorten the scanning time, you can have the  system skip inactive channels by activating the AutoSkip function.  Activate the AutoSkip Function:  Press the SKIP button on the front panel. The LED under the button is lit.    Turn off AutoSkip  Press the SKIP button and the LED light is off.  OSD Operation 1. (Optional) If the OSD is not onscreen, press the hot key twice  QUICKLY (default: Scroll Lock) to activate it.  2. Press F6 to activate the AutoScan function.  3. The OSD disappears, indicating the system enters the AutoScan  mode.  Starting from the currently selected channel, the system displays the  video of each channel one after another. Each channelʹs number and  name (if available) will pop up temporarily on the screen when the  channel is accessed. ...
  • Page 27: Returning To The Previous Channel

    Chapter 4: Advanced Operation and System Configuration Turn off AutoScan  Activate the OSD again and press Alt+F6.  Cycling Through Active Channels Only You can choose to skip inactive channels through the OSD after the  AutoScan function is activated. Therefore, only active channels are  scanned.  1. (Optional) If the OSD is not onscreen, press the hot key twice  QUICKLY (default: Scroll Lock) to activate it.  2. Press F7 to activate the AutoSkip function.  3. The OSD disappears, indicating the system enters the AutoSkip  mode.  Turn off AutoSkip  Activate the OSD again and press Alt+F7.  Returning to the Previous Channel MCCAT allows you to quickly return to the previously selected channel,  if any, by using a hot key without triggering the OSD or looking for the  corresponding button on the front panel.  Requisite for performing this function:  You must have activated the “Previous Channel” function in the  Configuration Menu. Otherwise, the hot key will not work. See System  Configuration (on page 26) for details.  Operation:  1.
  • Page 28: Refreshing The Channel Status

    Refreshing the Channel Status Refreshing the Channel Status From the OSD or LED status, you can tell which channel is connected to a  powered device and which is not. However, MCCAT does not support  real‐time channel detection. Besides, the OSD remembers and shows the  last second‐tier channel status instead of re‐detecting the second‐tier  channel status after the MCCAT unit is power cycled. Therefore, you  need to refresh the channel status shown in the OSD or LED if you have  made any changes to the hardware configuration, such as channel  swapping or disconnection and reconnection of computers. MCCAT  provides two methods to update the channel status:  • Use the F8 function key  • Use the AutoScan function  Using the F8 Function Key 1. (Optional) If the OSD is not onscreen, press the hot key twice  QUICKLY (default: Scroll Lock) to activate it.  2. Press F8 to upgrade the status. The system starts to check each  channel one by one and displays “Upgrade PC Status..” on the  screen.  3. Once the status checking is complete, both of the OSD and LED status  is updated.  Using the AutoScan Function The MCCAT unit checks all of the channels one by one and updates both ...
  • Page 29: The Security Feature

    Chapter 4: Advanced Operation and System Configuration The Security Feature You can prevent unauthorized access to the system and the attached  computers by activating the security feature. When the security feature is  ON, the system will enter the security mode after the mouse and  keyboard activity is not detected for a preset period of time. Users have to  enter a password in order to access the system in the security mode.  Activating the Security Feature 1. (Optional) If the OSD is not onscreen, press the hot key twice  QUICKLY (default: Scroll Lock) to activate it.  2. Press F5 and the prompt message “Admin. Password” appears on the  screen.  3. Type the Admin password (default: raritan) and press Enter. Note  that the password is case sensitive. The Administration Menu appears.    4. Make sure the Security field is already highlighted. If not, press Tab  or Shift+Tab to highlight the field.  5. Press   or   to change the option to On.    6. Press Tab to highlight the Time Out field. This field determines the  length of time for which keyboard and mouse activity can remain  inactive before the system enters the security mode.    7. Type two numeric digits or press   or   to adjust the time. ...
  • Page 30: Accessing The System In The Security Mode

    The Security Feature Accessing the System in the Security Mode After the system or the MCCAT unit enters the security mode, a message  “Security Mode Protected”appears on the screen. Do the following to  access the system:  1. Press any key and the prompt message “Password:” appears.  2. Type either the administrator (Admin) or user password and press  Enter. Unless changed, type one of the default passwords shown  below.  User Type Default Password (case sensitive) Administrator (Admin)  raritan  User1  111  User2  222  User3  333  User4  444  User5  555  Video of the currently selected channel appears on the screen if the  password is entered correctly. Now you can activate the OSD or press the  channel button to access any channel in the system. ...
  • Page 31: Changing The Keyboard Layout Setting

    Chapter 4: Advanced Operation and System Configuration 3. Type raritan and press Enter. Note that the password is case  sensitive. The Administration Menu appears.    4. Press Tab or Shift+Tab to highlight the field of which you want to  change the password; for example, if you want to change the  administrator password, highlight Admin.  5. Press Enter and the following fields appear.    6. Type the new password in the Enter New Passwd field and press  Enter. The maximum length of the password is eight characters.  7. Type the same password in the Confirm New Passwd field and press  Enter.  Now the password has been changed. In case you will forget new  passwords, it is suggested to note down new passwords and keep them  in a safe place.  Changing the Keyboard Layout Setting If you are using a non‐English keyboard, such as a French or German  keyboard, change the keyboard language setting to match the one you are  using.  1. (Optional) If the OSD is not onscreen, press the hot key twice  QUICKLY (default: Scroll Lock) to activate it.  2. Press F5 and the text “Admin. Password” appears on the screen. ...
  • Page 32: System Configuration

    System Configuration 3. Type the Admin password (default: raritan) and press Enter. Note  that the password is case sensitive. The Administration Menu appears.    4. Press Tab to highlight the Language Mode field. There are three  options available: English, German and French.  5. Press   or   to select the appropriate option.  6. Press Esc to quit the OSD menu.  System Configuration Many system settings are available in the Configuration Menu. Press F4 to  go to this menu when the OSD is onscreen.    Most of the settings can be adjusted by following this procedure:  1. Press Tab or Shift+Tab to move between fields. ...
  • Page 33 Model  No options  The field CANNOT be configured. It shows the  model name of the MCCAT unit.  Name  No options  Allows you to assign a name to the current  MCCAT unit for identification. The default is its  model name.  Device  x, y, z, . (dot)  Specifies the type of the device connected to each  channel of current MCCAT unit. If you connect a  second‐tier KVM switch, it is a must to specify the  type of this switch. The characters of this field  represent channel numbers 1, 2, 3, and so on from  left to right. The default value is ʺ.ʺ (dot).  The following lists the characters representing  different types of devices:  . (dot)  =  computer  x  =  MCC4  y  =  MCCAT18, MCC8  z  =  MCCAT116, MCC16  Scan  Toggles the AutoScan mode on or off.  On, Off  If it is ON, after you exit the OSD, the system  enters the scan mode (Global or Individual scan  mode) and cycles through all channels.  Set  05 ~ 99 (seconds)  Determines the length of time for which the  system scans each channel in the “Global”scan  mode. ...
  • Page 34 System Configuration Mode  Global, Individual  Determines which scan mode is applied once the  AutoScan function is activated. There are two  scan modes: Global and Individual.  • Global scan mode: The scan time for each  channel is the same.  • Individual scan mode: The scan time for each  channel varies depending on the settings you  have set for each channel in the Edit Names  and Scan Rate menu.  Skip  On, Off  Toggles the AutoSkip mode on or off.  If it is ON, after you exit the OSD, only active  channels can be accessed.  ID Display  01 ~ 99 (seconds)  Determines the length of time for which the  accessed channelʹs number (ID) appears on the  screen when the channel is selected.  Hotkey  ScrollLock, LftAlt (left Alt),  Determines which hot key can activate the OSD.  The default is Scroll Lock.  LftSht (left Shift),  CapsLock, NumLock  Note that if you have set any hot key in the  Previous Channel Key field, the same key will  not be available in the Hotkey field.  Display Position  Menu, ID  Determines the horizontal/vertical position where  the Menu (OSD menu) and/or the ID (channel  number) are displayed. To change the position,  do the following:  a.
  • Page 35: Setting The Scan Time For Individual Scan Mode

    Chapter 4: Advanced Operation and System Configuration On, Off  Toggles the power‐saving function on or off. If  Green Mode  setting the mode to On, the MCCAT unit will  enter the power‐saving mode after no  keyboard/mouse activity is detected for a period  of time specified in the Minutes field.  Minutes  01~99 (minutes)  Determines the length of time for which no  keyboard/mouse activity is detected before the  MCCAT unit enters the power‐saving mode.  Previous Channel  None, LftAlt (left Alt),  Determines which hot key is used for returning to  Key  LftSht (left Shift), Caplck  the previously selected channel. The default is  None.  (CapsLock), Numlck  (NumLock), Scrlck (Scroll  Note that the hot key which you have set in the  Lock)  Hotkey field will not be available in the Previous  Channel Key field.  Setting the Scan Time for Individual Scan Mode The scan time setting in the Configuration Menu is for “Global” scan mode. ...
  • Page 36: Accessing The Help Menu

    Accessing the Help Menu 4. Type numeric digits to change the scan time. The scan time is  measured in seconds.  5. Press Esc to quit the current menu.  6. The message “Save the changes [Y/N]” appears on the message bar.  Click Y to save the changes or N to abort them.    Accessing the Help Menu While the OSD is onscreen, you can view the OSD help at any time by  pressing F1. This displays the Help Menu, which lists all function keys  available and the current version of the firmware.    Functions Keys You can use any of the functions keys to go to any specific menu or  perform certain functions as long as the OSD remains onscreen:  Function Key Description F1  Displays the Help Menu.  F2  Displays the Selection Menu.  F3  Displays the Edit Names and Scan Rate menu. ...
  • Page 37: Resetting The System

    Chapter 4: Advanced Operation and System Configuration Function Key Description F4  Displays the Configuration Menu.  F5  Displays the Administration Menu.  F6  Turns on the AutoScan function.  Alt+F6  Turns off the AutoScan function.  F7  Turns on the AutoSkip function.  Alt+F7  Turns off the AutoSkip function.  F8  Checks channels one by one and updates the channel status accordingly.  F12  Toggles the channel sorting between sorting by “channel number” and  sorting by “name” in the Selection Menu.  Esc  Quits the current menu or the OSD interface.  Resetting the System To restore all MCCAT settings back to factory defaults, follow the  procedure below. Note that this function should be performed on the  first‐tier MCCAT unit alone f yours is a two‐tier system.  1. Power OFF the MCCAT unit.  2. Press the channel number 3 button on the front panel, and then  power ON the MCCAT unit.  3.
  • Page 38: Chapter 5 Two-Tier System

    Chapter 5 Two-Tier System You can cascade various MCCAT units to organize a two‐tier KVM  switch system and expand the number of available channels accordingly.  A mix of different MCCAT models is permitted. If the two‐tier system  completely comprises the MCCAT116 models, the number of connected  computers can even be expanded up to 256 computers.  In This Chapter Overview......................32  Setting Up a Two‐Tier System ...............33  Accessing the Second‐Tier Channels ............38  Overview When one or multiple MCCAT units are connected to the channel ports of  a single MCCAT unit, this KVM switch system is the so‐called ʺtwo‐tier  system.ʺ The former MCCAT units belong to the second tier, and the  latter is the first tier. You can connect computers to all channel ports  available in such a system, including those of the first tier and those of the  second tier.      Computers with CIMs attached    Cat5 UTP cables    Second‐tier MCCAT units ...
  • Page 39: Setting Up A Two-Tier System

    Chapter 5: Two-Tier System   First‐tier MCCAT unit    Keyboard, mouse and monitor (attached to the  first‐tier unit only)  Setting Up a Two-Tier System Basically, there are five major steps to set up a two‐tier system:  STEP 1: Programme an MCCAT unit as a second‐tier device  STEP 2: Connect the second‐tier MCCAT unit to the first‐tier  MCCAT unit  STEP 3: Connect the keyboard, mouse and monitor to the first‐tier  MCCAT unit  STEP 4: Specify the type of the second‐tier device in the  Configuration Menu  STEP 5: Connect computers to any MCCAT unit in the system  STEP 1: Programme an MCCAT Unit as a Second-Tier Device Each MCCAT unit is programmed as a first‐tier device when shipped out  of the factory. To set up a two‐tier MCCAT system, you have to  programme some MCCAT units as the second‐tier devices before  proceeding with the hardware installation.  1. Turn OFF the MCCAT unit.  2. Press the channel number 2 button on the front panel, and then  power ON the MCCAT unit. ...
  • Page 40: Step 2: Connect The Second-Tier Mccat Unit

    Setting Up a Two-Tier System STEP 2: Connect the Second-Tier MCCAT Unit Now you need to connect the second‐tier MCCAT units to the first‐tier  MCCAT unit. A mix of different MCCAT models is permitted in such a  system. For example, you can connect the MCCAT18 to the MCCAT116  unit.  Important: Use only MCIM‐PS2 to connect the second‐tier KVM  switches. Do NOT use other CIMs for connecting the second‐tier  switches.  1. Make sure all of the MCCAT units are turned OFF.  2. Attach an MCIM‐PS2 to an MCCAT unit that is programmed as a  second‐tier device:  a. Connect the PS/2 keyboard connector of the CIM to the PS/2  keyboard port of the MCCAT unit.  b. Connect the PS/2 mouse connector of the CIM to the PS/2 mouse  port of the MCCAT unit.  Connect the HD15 video connector of the CIM to the HD15 video  port of the MCCAT unit.   ...
  • Page 41 Chapter 5: Two-Tier System 3. Connect one end of the Cat5 UTP cable to the RJ45 port of the CIM  being attached to the second‐tier MCCAT unit; connect the other end  of the cable to one of the channel ports of the first‐tier MCCAT unit.    4. Connect one end of the power cord to the power jack of the MCCAT  unit and the other end to the appropriate power outlet.  5. If you want to connect more second‐tier MCCAT units to the first‐tier  MCCAT unit, repeat Steps 1 to 4.  6. Power ON the second‐tier devices first. After hearing the beep  sounds of the second‐tier devices, power ON the first‐tier device.  Note: Make sure you follow the above power‐on sequence; otherwise, the first‐tier  device may show incorrect channel status. ...
  • Page 42: Step 3: Connect The Keyboard, Mouse And Monitor To The First-Tier Device

    Setting Up a Two-Tier System STEP 3: Connect the Keyboard, Mouse and Monitor to the First-Tier Device Connect a keyboard, mouse and monitor to the first‐tier MCCAT unit.  For details, refer to Step 5 in Connecting Computers (on page 6).  STEP 4: Specify the Type of the Connected Second-Tier Device in the OSD MCCAT cannot detect which type of the second‐tier device is connected.  Therefore, you must specify the type(s) by yourself. Otherwise, you  cannot properly access the second‐tier channels.  To specify the type:  1. (Optional) If the OSD is not onscreen, press the hot key twice  QUICKLY (default: Scroll Lock) to activate it.  2. Press F4 and the Configuration Menu appears.   ...
  • Page 43 Chapter 5: Two-Tier System 4. The characters or dots (see the figure below), from left to right,  represent channel numbers 1, 2, 3, and so on of the first‐tier unit. If  the first‐tier unit contains 16 channels, you will see 16 characters or 16  dots in the field. Press   or   to select the character representing the  channel where the second‐tier device is connected.    5. Type the appropriate code that corresponds to the type of the  connected second‐tier device. For example, if you connect an  MCCAT18 unit to the channel number 3 of the first‐tier unit, type y in  the third character.    See the following table for all codes representing different types of  devices.  Code Type of device .  computer (or server)  x  MCC4  y  MCCAT18, MCC8  z  MCCAT116, MCC16  Note: For detailed information on other types of MasterConsole products, please  refer to MasterConsole II User Manual on the “User Manuals & Quick Setup  Guides” CD or on Raritanʹs Product Documentation webpage  (http://www.raritan.com/support/productdocumentation).  Default Name of the Second-Tier Device The following default names of the second‐tier devices appear in the ...
  • Page 44: Step 5: Connect Computers To The Mccat System

    Accessing the Second-Tier Channels STEP 5: Connect Computers to the MCCAT System You can connect computers to available channel ports of any MCCAT  units in the two‐tier system, including those of the first‐tier and  second‐tier MCCAT units. For details, see Steps 2 to 4 in Connecting  Computers (on page 6).  Accessing the Second-Tier Channels Unlike the first‐tier channels, there is only one way to access the  second‐tier channels, that is, through the OSD. If you have properly  followed the procedure described in Setting Up a Two‐Tier System (on  page 33), the second‐tier channels will be displayed in the OSD, following  the page(s) of the first‐tier channels. To access these channels, do the  following:   1.  (Optional) If the OSD is not onscreen, press the hot key twice  QUICKLY (default: Scroll Lock) to activate it. The Selection Menu  appears. Note that the names of all second‐tier devices start with “/”  like channel number 3 and 6 illustrated below.    2. There are several methods to go to the second‐tier channels. Do one  of the following:  Press   or   to highlight the first‐tier channel where the desired  second‐tier device connects, and press Enter. The channel list of  the selected second‐tier device appears.  Press the “Key” number of the first‐tier channel where the desired ...
  • Page 45 Chapter 5: Two-Tier System Press Page Down or Page Up until you see the page where the  desired second‐tier channel is available.  Note: A second‐tier channel is always shown with two channel  numbers: the first one is the number of the first‐tier channel where  the second‐tier device connects, and the second one is the number of  the second‐tier channel where the computer connects.    3. Press   or   to highlight the desired channel among the second‐tier  channels.  4. Press Enter to select the channel.  Now you can control the accessed computer with the keyboard and  mouse attached to the first‐tier MCCAT unit.  Important: If you have made physical changes to channels, such as  disconnection or swapping of connected computers, it is strongly  recommended to refresh the channel status before accessing the  channels through OSD. This is because MCCAT does not  automatically update its channel status when the changes occur. For  instructions on refreshing the channel status, see Refreshing the Channel  Status (on page 22). ...
  • Page 46: Chapter 6 Firmware Upgrade

    STEP 4: Power cycle the upgraded MCCAT unit  Note: If your system consists of two or more MCCAT units, you should upgrade  each of them, starting from the first tier to the second tier.  In This Chapter STEP 1: Download the Latest Firmware and Upgrade Utility ....40  STEP 2: Connect the MCCAT Unit to the Computer Running the Upgrade  Utility.........................41  STEP 3: Launch the Upgrade Utility .............42  STEP 4: Power Cycle the Upgraded MCCAT Unit ........44  STEP 1: Download the Latest Firmware and Upgrade Utility 1. Use your browser to visit Raritanʹs Firmware Upgrades webpage  (http://www.raritan.com/support/sup_upgrades.aspx).  2. Click MasterConsole to locate the latest firmware version for  MCCAT.  3. Click the firmware (*.hex).  4. Click Save and specify the location to save the file.  5. Wait until the download completes. The downloaded file contains the  *.hex firmware file and the upgrade utility.  6. (Optional) If associated release notes are NOT included in the  downloaded file, locate the release notes on the same Frimware  Upgrades page, and double click it to either open or download it. ...
  • Page 47: Step 2: Connect The Mccat Unit To The Computer Running The Upgrade Utility

    Chapter 6: Firmware Upgrade STEP 2: Connect the MCCAT Unit to the Computer Running the Upgrade Utility 1. Prepare one DB9 male‐to‐female serial (RS‐232) cable.  Note: If you donʹt have this cable, contact Raritan technical support  for details.  2. Connect one end of the serial cable to one of the serial ports of the  computer; connect the other end to the Admin port of the MCCAT  unit.   ...
  • Page 48: Step 3: Launch The Upgrade Utility

    STEP 3: Launch the Upgrade Utility STEP 3: Launch the Upgrade Utility The upgrade utility for MCCAT is the same one for Raritanʹs Paragon  products, that is, the ParagonUpdate utility. However, the  ParagonUpdate utility which is implemented with the capability to  upgrade the MCCAT units starts from version 2.4.3. To ensure the success  of the upgrade, it is strongly recommended to use the upgrade utility  downloaded along with the MCCAT firmware when upgrading MCCAT  units.  1. Double click the downloaded upgrade utility ‐‐  ParagonUpdate_XXX.exe, where XXX represents the version number.  The firmware upgrade utility appears.    2. If the MCCAT unit intended to upgrade is already listed in the dialog,  go to Step 3. If not, do the following to specify the device that you  want to upgrade:  a. Click New to start adding the device information.  b. Click the Name field and type the appropriate name for the  MCCAT unit you want to upgrade.  Ensure <Default Serial> is selected in the IP address/Serial field  for the serial connection between the MCCAT unit and the  computer you are operating. ...
  • Page 49 Chapter 6: Firmware Upgrade d. Click the Port field and type the appropriate number of the serial  port. For example, if the MCCAT unit connects to the computer  via COM 1, type 1.  Ensure <Default No Encryption> is selected in the Encryption  Key field.   (Optional) Click Save to save the device information so next time  you donʹt have to specify the same information again.    3. Select the checkbox next to the MCCAT unit.    4. Click Load Hex File . The Open dialog appears.  5. Navigate to where the desired firmware file (*.hex) is located, select it  and click Open.    6. Click Raritan MasterConsole to perform the upgrade.  Note: The “Check Device Information” button is disabled with the  MCCAT unit. Therefore, never click it when the device intended to  upgrade is MCCAT. ...
  • Page 50: Step 4: Power Cycle The Upgraded Mccat Unit

    STEP 4: Power Cycle the Upgraded MCCAT Unit 7. Click Yes when the following message box appears.    8. A progress indicator is shown on the bottom of the dialog, displaying  the upgrade status. The upgrade may last for several minutes.    9. The “Device Update Successful” message appears when the upgrade  completes successfully. Click OK.    For more information on the ParagonUpdate utility, see Paragon  Manager User Guide on the “User Manuals & Quick Setup Guides” CD  or on Raritanʹs Product Documentation webpage  (http://www.raritan.com/support/productdocumentation).  STEP 4: Power Cycle the Upgraded MCCAT Unit After completing the firmware upgrade, you must power OFF and then  power ON the upgraded unit to ensure the upgrade success. ...
  • Page 51: Appendix A Specifications

    Appendix A Specifications In This Chapter Measurement....................45  Supported Resolutions..................45  Measurement MCCAT18  1U  Dimension:  Weight:  (8‐channel model)  rackmountable  17.32”(W) x 7.20”(D) x 1.73”(H) or  5.30 lb or 2.40 kg 44 cm (W) x 18.3 cm (D) x 4.4 cm (H) MCCAT116  1U  Dimension:  Weight:  (16‐channel model)  rackmountable  17.32”(W) x 7.20”(D) x 1.73”(H) or  5.35 lb or 2.42 kg 44 cm (W) x 18.3 cm (D) x 4.4 cm (H) Supported Resolutions Screen Resolution Refresh Rate (HZ) 640x350  70, 85  640x400  85  640x480  60, 67, 72 ...
  • Page 52: Appendix B Mccat Default Settings

    Appendix B MCCAT Default Settings Field or Function Factory Default Setting Administration password  raritan (note the password is case sensitive)  AutoScan  OFF  AutoScan mode  Global  AutoSkip  OFF  Scan time per channel in the Individual scan  5 seconds  mode  Device  “.” (a dot represents the device is a computer)  Scan time per channel in the Global scan  5 seconds  mode  Hot Key  Scroll Lock  ID Display Interval  3 seconds  MCCAT tier configuration  First tier  Power‐saving mode (Green Mode)  OFF  Power‐saving delay time  15 minutes  Security  OFF  Security activation delay time ...
  • Page 53: Appendix C Compatibility With Other Raritan Products

    Appendix C Compatibility with Other Raritan Products You can connect other Raritan products to the MCCAT unit, such as  MasterConsole II, which can work as the second tier, or P2CIM‐SER,  which enables the connection of an ASCII serial device to the MCCAT  unit.  In This Chapter Compatible CIMs.....................47  Compatibility with MasterConsole II ............49  Compatible CIMs In addition to MCIM‐PS2 and MCIM‐USB, MCCAT is also compatible  with other Raritan CIMs (see the table below).  The procedure of connecting these CIMs is the same as that of connecting  MCIM. For details, see Connecting Computers (on page 6).  Connector Type P2CIM‐APS2  PS‐2 and HD15 (video) connectors  P2CIM‐AUSB  USB and HD15 (video) connectors  P2CIM‐PS2  PS‐2 and HD15 (video) connectors  P2CIM‐USB  USB and HD15 (video) connectors  DCIM‐APS2  PS‐2 and HD15 (video) connectors  DCIM‐USB  USB and HD15 (video) connectors  DCIM‐USB G2 **  USB and HD15 (video) connectors  P2CIM‐SER ...
  • Page 54: Connecting A Serial Device Via The Serial Cim

    Compatible CIMs Connecting a Serial Device via the Serial CIM To connect an ASCII serial device, LAN/WAN component or a computer  through a serial port (RS‐232) to the MCCAT system, use one of Raritanʹs  serial CIMs: P2CIM‐SER or P2CIM‐SER‐EU. These CIMs can emulate an  ASCII terminal and convert the serial data from the ASCII device to VGA  video (800x600x60) and PS/2 keyboard signals. This conversion allows  users to access and operate any ASCII serial device connected to the  MCCAT system.  Here are some useful features of the serial CIMs:  • Interoperates with an ASCII device in the On Line Mode as if the  device were attached to a text terminal  • Edits, copies, marks, and/or resends data to the ASCII serial device or  computer in the Buffer Edit Mode  • Maintains eight pages of data in a circular buffer  • Provides 12 programmable keys for frequently‐used character strings  or commands  Note: The P2CIM‐SER and P2CIM‐SER‐EU are functionally identical. The only  difference between the two is that the P2CIM‐SER‐EU supports a wider variety  of non‐English language keyboards and character sets.      DB9 connector    USB connector    RJ45 connector ...
  • Page 55: Compatibility With Masterconsole Ii

    Appendix C: Compatibility with Other Raritan Products Installing a Serial CIM Take these steps to attach a serial CIM to the serial port of a serial device  or computer and to your MCCAT system.  1. Connect the CIM to a serial port on the serial device or computer,  using its serial DB9 connector.  2. Connect the CIM to the MCCAT system using a standard Cat5 UTP  cable.  3. Connect the CIMʹs USB connector to a powered USB port, or to a  separately available Raritan PWR‐SER‐4 power adapter, to obtain  power.  For detailed information on the CIMs, see Paragon and Dominion KX  Serial Device CIM User Guide (see Serial Device CIM User Guide ‐  http://www.raritan.com/_downloads/pdfs/products/P2CIM‐SER%20User %20Guide.pdf). This user guide can be downloaded from Raritanʹs  website.  Compatibility with MasterConsole II MCCAT is able to work in conjunction with MasterConsole II products,  including MCC4, MCC8 and MCC16. These MasterConsole II units can  function as the second‐tier devices of the MCCAT system.  The procedure of connecting MasterConsole II products is the same as  that of connecting MCCAT units.  • STEP 1: Programme a MasterConsole II unit as a second‐tier device  •...
  • Page 56: Step 2: Connect The Second‐Tier Masterconsole Ii Units

    Compatibility with MasterConsole II 3. The rightmost LED on the front panel is lit, indicating the device is  now programmed as a second‐tier device.  4. Repeat Steps 1 to 3 if more MasterConsole II units are to be  programmed as the second‐tier devices.  STEP 2: Connect the Second-Tier MasterConsole II Units 1. Attach a PS/2 CIM to a MasterConsole II unit that is programmed as a  second‐tier device.  2. Connect one end of the Cat5 UTP cable to the RJ45 port of the CIM  being attached to the second‐tier MasterConsole II unit; connect the  other end of the cable to one of the channel ports of the first‐tier  MCCAT unit.  3. Connect one end of the power cord to the power jack of the  MasterConsole II unit and the other end to the appropriate power  outlet.  4. If you want to connect more second‐tier MasterConsole II units to the  first‐tier MCCAT unit, repeat Steps 1 to 3.  5. Power ON the second‐tier devices first. Then power ON the first‐tier  MCCAT unit.  STEP 3: Specify the Type of the Connected Second-Tier Device in the OSD You must specify the type of the connected device in the Configuration ...
  • Page 57: Appendix D Troubleshooting

    • The monitor probably does not match the video outputs. If the  The monitor cannot  monitor is a single mode type VGA, all computers must have the  correctly display the  same type of video output.  video output from some  of the computers  • (Note: this problem occurs most often with some IBM PS/2s and IBM 63xx,  85xx, and 95xx monitors.) The intelligent type display card outputs  video signals based on the monitor ID‐pin setting in the connector of  the monitor cable. If the ID‐pin setting is incorrect, the monitor  attached to the MCCAT may have no display, become monochrome  instead of color, or become unstable. If this is the case, you will need  to provide a proper ID‐pattern to the display card. Call Raritan  technical support (see the last page) for help if necessary.  • Make sure the keyboard is connected firmly to MCCAT. Disconnect  All computers powered  and reconnect the keyboard.  up without keyboard  error, but the keyboard  • Replace the keyboard. (MCCAT allows hot re‐connection of the  attached to MCCAT has  keyboard at its Keyboard port.)  no control (cannot input  • In a two‐tier configuration, check that the MCCAT with the  to any computer)  keyboard connected is the first tier.  • The keyboard cable from the CIM to the computer is loose. Secure  Repeated “KB ERRORʺ ...
  • Page 58 • Check the keyboard connection.  computers are selected  • The mouse cable from the CIM to the computer is loose. Secure the  Repeated ʺMOUSE  connection and power on the computer again.  INSTALLATION  FAILUREʺ at power‐up  • If the problem only occurs to new computers which are just added  of computer.  to the system, the firmware in the KVM (MCCAT internal mouse  emulator) may need to be upgraded to a later version to be  compatible with newer computers. Contact your dealer or Raritan  for service.  • Try to identify if the problem is originating from the computer by  After a period of  reconnecting the computer to a different channel with a different  trouble‐free operation,  cable. Then power on the computer. If the problem is not with the  the mouse attached to  cable or with a specific channel, connect the mouse directly to the  MCCAT locks (unable to  computer. If the problem persists, then the computerʹs mouse port is  control mouse functions)  out of order. Otherwise, contact your dealer or Raritan for service.  when a particular  computer is selected, but  • If the problem occurs after MCCAT has been installed for a period  works normally when  of time, and occurs to computers that have previously worked with ...
  • Page 59: Index

    OSD Operation • 10, 20  Accessing the Second‐Tier Channels • 38  Overview • 32  Accessing the System in the Security Mode •  24  Activating the OSD • 13  Package Contents • 3  Activating the Security Feature • 23  Product Features • 2  Advanced Operation and System  Product Overview • 1  Configuration • 4, 17  Product Photos • 1  Changing Channel Names • 11, 16  Quick Start • 4  Changing Passwords • 24  Changing the Keyboard Layout Setting • 25  Compatibility with MasterConsole II • 49  Rear View • 5  Compatibility with Other Raritan Products •  Refreshing the Channel Status • 22, 39  47  Resetting the System • 31  Compatible CIMs • 47  Returning to the Previous Channel • 21  Connecting a Serial Device via the Serial  CIM • 48  Connecting Computers • 6, 36, 38, 47  Selecting a Channel • 9  Cycling Through Channels • 19, 22  Setting the Scan Time for Individual Scan  Mode • 29  Setting Up a Two‐Tier System • 5, 33, 38  Firmware Upgrade • 40  Specifications • 45  Frequently Used Keys • 14  STEP 1  Front Panel Operation • 9, 19  Download the Latest Firmware and Front View • 4 ...
  • Page 60 Index Connect the Keyboard, Mouse and Monitor to the First-Tier Device • 36 Launch the Upgrade Utility • 42 Specify the Type of the Connected Second-Tier Device in the OSD • 50 STEP 4  Power Cycle the Upgraded MCCAT Unit • Specify the Type of the Connected Second-Tier Device in the OSD •...
  • Page 61: United Kingdom

      U.S./Canada/Latin America Monday ‐ Friday   8 a.m. ‐ 8 p.m. ET   Phone: 800‐724‐8090 or 732‐764‐8886  For CommandCenter NOC: Press 6, then Press 1  For CommandCenter Secure Gateway: Press 6, then Press 2  Fax: 732‐764‐8887  Email for CommandCenter NOC: tech‐ccnoc@raritan.com  Email for all other products: tech@raritan.com  China Europe Beijing, China Europe Monday ‐ Friday   Monday ‐ Friday  9 a.m. ‐ 6 p.m. local time   8:30 a.m. ‐ 5 p.m. GMT+1 CET   Phone: +86‐10‐88091890  Phone: +31‐10‐2844040   Email: tech.europe@raritan.com  Shanghai, China United Kingdom Monday ‐ Friday   9 a.m. ‐ 6 p.m. local time   Monday ‐ Friday   Phone: +86‐21‐5425‐2499   8:30 a.m. to 5 p.m. GMT+1 CET   Phone +44‐20‐7614‐77‐00   GuangZhou, China France Monday ‐ Friday   9 a.m. ‐ 6 p.m. local time   Monday ‐ Friday   Phone: +86‐20‐8755‐5561  ...