Sarara" Drying / Dry Cooling Operation - Daikin SiBE04-624_B_FTXR-E Service Manual

Wall mounted type e-series
Table of Contents

Advertisement

Main Functions
1.7

"SARARA" DRYING / DRY COOLING Operation

Operation
Features of
"SARARA"
DRYING
30
DRY COOLING
operation
Reheating dehumidifying method
A powerful evaporator eliminates the humidity in the room exclusively. Dry, cool air is mixed
with warm air from the reheater, thereby blowing in optimal and comfortable dry air.
Indoor heat exchanger
as evaporator
(cooled)
Optimal comfortable air
Adjustable at your preferred humidity even during cooling
You can get comfortable coolness even during moderate cooling because you can adjust the
indoor humidity as you like. By decreasing the temperature gap between indoor and outdoor,
you can avoid a heat shock. This feature is recommended for ladies or elders who are
sensitive to cooling, for families with a baby, as well as for energy saving.
Cooling
Room temperature
32˚C
It is recommended to
keep the temperature
gap between indoor and
outdoor within 5˚C.
27˚C
26˚C
"SARARA" DRYING
operation
Indoor heat exchanger as
condenser (warmed)
mixed together
Save energy by 10%, when
temperature is set to 1˚C higher
START
Moderate
cooling
Same
cool feeling.
40%
SiBE04-624_B
(R13875)
(R13876)
Normal
cooling
70%
(R18143)
Function and Control

Advertisement

Table of Contents
loading